GENERAL SPECIFICATIONS DIVISIONIX-FINISHES DIVISIONXV-MECHANICAL DL5I6NLK:
<br /> 09250 GYPSUM DRYWALL AND METAL STUDS 15400-PLUMBING
<br /> PROJECT NOTES 1. INCLUDE NECESSARY MATERIALS,LABOR,AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 1. PROVIDE SUPPLY,WASTE AND VENT LINES,VALVES,FITTINGS,ETC.REWIRED FOR KITCHEN SINKS,DISHWASHER,REFRIGERATOR,AIR
<br /> 1. THESE PROJECT NOTES ARE GENERIC IN NATURE.CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED 2 "WALL SURFACES"MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED,CONVECTOR OR RADIATOR ENCLOSURES, CONDITIONING UNIT(S),VENDING MACHINES,COFFEE MAKER,WATER HEATERS,ETC.
<br /> ON THE CONTRACT BETWEEN MANAGEMENT AND TENANT.VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND FASCIAS,RETURNS,PLYWOOD BACKBOARDS,ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS PATH DISABILITIES ACT.
<br /> CONSTRUCTION ADMINISTRATION RESPONSIBILITIES.THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD,UON. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS,OR PER BUILDING STANDARD,UON.
<br /> 2. PLUMBING,ELECTRICAL,MECHANICAL&LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN/BUILD CONTRACT.ALL WORK SHALL 4.WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE,UON. 4. PROVIDE HOT AND COLD WATER TO SINKS/DISHWASHERS IF APPLICABLE.
<br /> BE TO CODE.ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMATIC DESIGN ONLY.VERIFY REQUIREMENTS OF 5. SEISMIC BRACING:PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND CEILING 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED NTH A DRIP PAN CONNECTED TO WASTE UNE.VERIFY LOCATIONS WITH BUILDING
<br /> BUILDING MANAGEMENT AND TENANT.RENEW OF SHOP DRAWINGS,IF APPROPRIATE,IS FOR AESTHETIC REASONS ONLY. GRID. MANAGEMENT AND INSPECTORS.
<br /> 3. VERIFY BUILDING STANDARDS WITH BUILDING MANAGEMENT WIZEN WORKING IN SUITES NTH NON BUILDING STANDARDS ELEMENTS. 6. FRAMING STUDS:GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS.PROVIDE NTH SHEET METAL BACKING WITHIN ALL WALLS 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES.
<br /> VERIFY PREFERRED DETAILING OF THESE ELEMENTS NTH BUILDING MANAGEMENT. RECEIMNG CASEWORK(CABINETS,BOOKSHELVES,ETC.).VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCKS IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL CNS D E S I G N
<br /> 4. VERIFY ALL RULES,GENERAL CONDITIONS AND SPECIALIZED BUILDING REQUIREMENTS NTH THE BUILDING MANAGEMENT. 7.CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS,PLUMBING, PRIOR TO INSTALLATION.
<br /> 5. VERIFY LEED REQUIREMENTS NTH BUILDING MANAGEMENT. AND ELECTRICAL WORK.FIRE RATE AS REQUIRED. 8. VERIFY WATER SUPPLY AND SEWER DRAIN CAPACITY FOR ENTIRE BUILDING WILL MEET NEW CAPACITY WIZEN NEW RESTROOMS ARE IMAGINE - DESIGN - DELIVER
<br /> 8. ALL DRYWALL TO BE 5/8"TWE"X"UNLESS OTHERWISE NOTED.PROVIDE"M/R"TYPE DRYWALL MERE REQUIRED BY CODE AND AT ADDED TO BUILDING.
<br /> ALL TOILET ROOMS AND WET OR DAMP AREAS. PROVIDE CEMENT BACKER BOARD BEHIND TILE CONDITIONS,LION. CELL:425-941-9494
<br /> DIVISION I-GENERAL CONDITIONS 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS.INSTALL METAL EDGE TRIM WHEREVER EDGE IF GYPSUM BOARD WOULD 15500-FIRE PROTECTION
<br /> OTHERWISE BE EXPOSED OR SEMI-EXPOSED. 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD,LOCAL REGULATIONS AND ORDINANCES.
<br /> 01010 SUMMARY OF WORK 10.PRIOR TO RECEIVING FINISH,ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 2. PROVIDE ALL EMERGENCY LIGHTING,EXIT SIGNS,FIRE ALARM SPEAKERS,STROBES AND BELLS AS REQUIRED BY CODE.DESIGN AND
<br /> 1. GENERAL DESCRIPTION OF THE PROJECT:NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE,UON. 11.EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE.PROVIDE STRUCTURAL DIAGONAL BRACING AS NECESSARY. INSTALL THE SAME IN COMPLIANCE NTH THE AMERICANS WITH DISABILITIES ACT.
<br /> 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS"BUILDING STANDARD'ON THE PLANS,THE CONTRACTOR 12.PROVIDE FRAMING FOR SUSPENDED CEILING NTH SEISMIC BRACING IN ACCORDANCE NTH REQUIREMENTS OF APPLICABLE CODES AND 3. PROVIDE SPRINKLERS,FIRE RATER DOORS AND FRAMES,FIRE EXTINGUISHERS,ETC.AS REQUIRED BY APPLICABLE LOCAL CODES AND
<br /> SHALL SO ADVISE THE ARCHITECT WITHIN TEN(10)DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT THE ARCHITECT AS SHOWN ON DRAWINGS. LAWS.
<br /> MAY MAKE ALTERNATIVE SELECTIONS. 13.USE ACOUSTICAL SEALANT AROUND ALL PIPES,DUCTS,CONDUIT OUTLETS,SWITCHES,ETC.ON BOTH SIDES OF 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITERS'LABORATORY 2A-10BC 5-LB,MULTIPURPOSE.EXTINGUISHERS NTH SQUEEZE TWE
<br /> 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT,INCLUDING CROSSING/PENETRATION WALLS NTH ACOUSTICAL INSULATION.PENETRATIONS OF FIRE-RATED WALLS SHALL BE PROTECTED BY HANDLE AND FLEXIBLE DISCHARGE HOSE NTH VISIBLE PRESSURE GAUGE,UON.
<br /> REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERMCES,AND IS RESPONSIBLE FOR ALL ROUGH-IN CONNECTIONS.EACH APPLICABLE FIRE-RATED ASSEMBLES AND MATERIALS. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS,LION.VERIFY LOCATION NTH FIRE MARSHALL
<br /> SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 14.FlRE AND SMOKE SEPARATION ASSEMBLES HALL BE MARKED AS REWIRED IN SECTION 703.6. HIEN REQUIRED BY CODE,PROVIDE 1 WALL MOUNT TWE IN EACH SERVER ROOM OR LABORATORY.
<br /> 4. FIRE/EMERGENCY SYSTEMS INCLUDE,BUT ARE NOT LIMITED TO,SPRINKLER MODIFICATIONS,FIRE EXTINGUISHER PLACEMENT,AUDIBLE 6. DESIGN BUILD FIRE FIRE PROTECTION DRAWINGS SHALL INDICATE:
<br /> ALARMS,SMOKE AND HEAT DETECTORS STROBES,AND EXIT SIGN PLACEMENT. 09500-CEILING SUSPENSION SYSTEMS A.LAYOUT,LOCATION,AND SIZE OF SPRINKLER LINES AND HEADS.
<br /> 5. ALL DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR. 1. PROVIDE NEW CEILING TILE,CEIUNG GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILING AS B.PRESSURE REQUIREMENTS.
<br /> 6. WORK NOT INCLUDED:CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE INDICATED ON DRAWINGS. C.SPRINKLER HEAD SPECIFICATIONS.
<br /> PLANS EXCEPT FOR THE ITEMS INDICATED°N.I.C."(NOT IN CONTRACT).SUCH AS TELEPHONE AND DATA CABLES,OFFICE FURNITURE, 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY.VERIFY NTH BUILDING MANAGEMENT IF EXISTING D.LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS.
<br /> EQUIPMENT AND MOBILE KITCHEN APPLIANCES. CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR
<br /> 7. CONTRACTOR TO PROVIDE ALL FIRE/EMERGENCY SYSTEMS AS REWIRED BY ALL APPLICABLE CODES.FIRE/EMERGENCY SYSTEMS 3. COORDINATE WORK WTH OTHER TRADES HAMNG WORK IN THE CEILING AND TELEPHONE AND DATE CABLE COMPANIES WHEREVER TO INSTALLATION.INCLUDE HORNS AND STROBES.
<br /> INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS,FIRE EXTINGUISHERS,AUDIBLE ALARMS,STROBES,SPRINKLERS,SMOKE AND THEIR RESPECTIVE WORK IS CONTIGUOUS. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE,UON.
<br /> HEAT DETECTORS,AND EXIT SIGNS. 4.PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES,REGISTERS, 9. USE OF NFPA 13 WICK RESPONSE HEADS MAY BE REQUIRED.CONTRACTOR SHALL VERIFY EXTENT OF QUICK RESPONSE HEADS BY
<br /> 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, DIFFUSERS,SPRINKLERS,AND OTHER INSERTED ITEMS. THE AHJ FOR THIS PROJECT.
<br /> AND SHALL BE EQUIPPED NTH PANIC HARDWARE MERE REQUIRED AND INDICATED. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE,UON.
<br /> 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE NTH MANUFACTURER'S 15800-HEATING AND AIR CONDITIONING
<br /> 10.ALL ELECTRICAL,PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY NTH THE BUILDING SHELL STANDARD SPECIFICATIONS AND CODES. 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS,LABOR,AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM.
<br /> SPECIFICATIONS. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE,LEVEL,AND PERFECTLY ALIGNED NTH EACH OTHER. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED.
<br /> 11.THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY NDH THE REQUIREMENTS OF CONTRACT DOCUMENTS AND WILL 8. INSTALLED SUSPENDED CEIUNGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8"IN 12-0".ANCHOR AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DOCUMENTS SHALL INDICATE:
<br /> BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL UNES AND DIMENSIONS.BEFORE DOING AND WORK, 9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO AUGN,LEVEL,AND MATCH NEW A.DUCTS,AIR MOVEMENT REQUIREMENTS,&SIZES OF GRILLES®ISTERS.
<br /> THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDITIONS AT THE SITE AND NOTIFY THE ARCHITECT OF ANY CEILING TO OLD.CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR
<br /> DISCREPANCIES. MANAGEMENT OF ANY DISCONTINUITIES IN THE CEIUNG WITHIN 10 DAYS. TO INSTALLATION.
<br /> 12.THE CONTRACTORS SHALL USE DIMENSIONS ONLY.DO NOT SCALE PLANS. 10.ADJUST PARTITION HEAD DETAIL TO MATCH EXISTING CONDITIONS IF NECESSARY. 4. HVAC CONTRACTOR TO CLEAN,REPAIR,OR REPLACE SOILED OR DAMAGED HVAC GRILLS,FILTERS AND THERMOSTATS.
<br /> 13.MATERIALS:ALL MANUFACTURED ARTICLES,MATERIALS AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY MANUFACTURERS. 5. RE-ZONE,ALTER OR SEPARATE HVAC AS NECESSARY AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES.
<br /> ALL UKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED.ALL MATERIAL, 09530-ACOUSTICAL TREATMENT
<br /> EQUIPMENT AND FIXTURES SHALL BE CODE WORTHY NTH ALL PROPER JURISDICTION APPROVALS. 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HE16000-ELECTRICAL AND TELECOMMUNICATIONS
<br /> 1. REUSE EXISTING ELECTRICAL AND DATA IAS O
<br /> AD ABOVE APPROPRIATE TO MEET THE TENANTS REQUIREMENT.REPLACE OUTLET COVER PLATES TO
<br /> CEILINGS FOR ALL WALLS NOTED PER PLANS. MATCH NEW FINISH IF RIC LCALE.
<br /> DIVISION 11-SITE WORK 2.NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON
<br /> EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID,UON. 2 PROVIDE ALL WORK,EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM PROVIDE ELECTRICAL OUTLETS
<br /> PER POWER AND DATA PLAN.
<br /> 02050-DEMOLITION 09650-RESILIENT FLOORING 3. PROVIDE MUG RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN.EACH MUG RING TO HAVE A
<br /> 1. FURNISH ALL LABOR,MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED 1. PROVIDE VCT,SHEET LINOLEUM,SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS.COLOR AND MANUFACTURER PER MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS.COORDINATE DATA CABLE CONFIGURATION NTH THE TENANT.
<br /> IN THE CONSTRUCTION AREAS.UPON COMPLETION OF ALL DEMOUTION WORK,ALL AREAS SHALL BE LEFT BROOM CLEAN. FINISH SCHEDULE. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18°A.F.F.TO THE CENTER LINE,UON.
<br /> 2. DEMOLITION OF TELEPHONES,ELECTRICAL VOICE/DATA AND PANELS ARE TO BE REMOVED BACK ORIGINATING SOURCE.DEMOLITION OF 2. PROVIDE RUBBER-REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE.REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR 5. WERE MULTIPLE DEWSES OCCUR IN A SINGLE LOCATION,ALL DEVICES SHALL BE GANGED,LION.
<br /> CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. MATERIAL TRANSITION. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT.
<br /> 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS PROTECTION PROTOCOLS SHOULD BE STRICTLY FOLLOWED 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH NTH NO PIECES LESS THAN 12".NO JOINTS AT OUTSIDE CORNERS OR WITHIN 7. ALL WIRING DEVICES:SHALL BE BUILDING STANDARD EXCEPT:"ISOLATED GROUND"OUTLETS SHALL BE ORANGE,"HOSPITAL GRADE
<br /> PER CODE AND/OR LOCAL GOVERNING AUTHORITY. 6"OF CORNERS. ISOLATED GROUND"OUTLETS SHALL BE ORANGE NTH A GREEN DOT,"EMERGENCY"OUTLETS SHALL BE RED,AND"DEDICATED"
<br /> 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN/SPACE PLAN 4.PATCH LEVEL AND PREPARE SUB FLOORING NTH CEMENTITIOUS UNDERLAY PER MFR'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE OUTLETS OR"CLEAN CIRCUIT"FIXTURES SHALL BE GRAY(UNLESS BUILDING STANDARD DICTATES OTHERWISE).ALL COVER PLATES
<br /> NTH WORK LETTER SHALL BE REMOVED,RELOCATED OR KEPT FLUSH IN CEIUNG,WALL OR FLOOR AS REQUIRED. NEW FLOORING.MAX.ALLOWABLE TOLERANCE=1/4"OVER 10'. SHALL BE BUILDING STANDARD FINISH,UON.VERIFY NTH BUILDING MANAGEMENT.
<br /> 5. ALL DAMAGED,ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT 5.GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATIONS,UON. 8. PROVIDE SEPARATE CIRCUITS FOR TENANTS EQUIPMENT(INCLUDING THE TELEPHONE SWITCH,COPIERS,COMPUTERS,ECT.)MEN
<br /> AREAS OR AS SPECIFIED TO PROVIDE A°UKE-NEW FINISH". 6. UNLESS SPECIFIED ALL RUBBER BASE SHALL BE COVED BASE. NOTED ON THE CONSTRUCTION DOCUMENTS.
<br /> 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL,DUST AND DEBRIS SUCH THAT IT 9. COORDINATE SCHEDULE NTH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANTS NEW PROJECT_
<br /> DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. 09680-CARPET FURNITURE.
<br /> 1. PROVIDE AND INSTALL COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 10.ALL ELECTRICAL WRING,TELEPHONE AND COMPUTER CABLING,AND CONDUIT SHALL BE CONCEALED IN FLOORS,WALLS OR CEIUNGS.
<br /> DIVISION VI-ARCHITECTURAL CARPENTRY AND CASEWORK 2.PREPARE SUB FLOOR WITH CEMENTITIOUS UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE.MAX ALLOWABLE CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANTS VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER,
<br /> TOLERANCE=1/4"OVER 10'. UON.
<br /> 06100-ROUGH CARPENTRY 3.PROVIDE SEAMING DIAGRAMS FOR ARCHITECTS REVIEW. 11.THE CONTRACTOR IS TO COORDINATE NTH THE TENANTS SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT UNITED TO:
<br /> 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS,FURRING,BLOCKING,ROUGH FRAMING,WOOD CURBS,BUCKS,NAILERS,BACKING, ELECTRICAL AND DATA WRING LOCATIONS,J-BOX LOCATIONS,CONNECTIONS AND WALL MOUNTED REQUIREMENTS.
<br /> FIXTURE FRAMING,EQUIPMENT SUPPORTS,ETC.AS DETAILED. NOT ALL ROUGH FRAMING MAY BE SHOWN OR DETAILED. 09900-PAINTING AND STAIN 12.THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET HOTWORX
<br /> 1. UNLESS OTHERWISE NOTED,PRIME ALL GWB WALL SURFACES AND PAINT NTH MINIMUM OF TWO(2)FINISH COATS OF BENJAMIN CURRENT FLAME SPREAD REGULATIONS.LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED.FLOOR SHALL BE
<br /> 06200-FINISH CARPENTRY MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL,UON.PROVIDE FOR NUMBERS OF PAINT COLORS AS INDICATED IN LEFT FLUSH. STUDIO
<br /> 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS,HARDWARE AND NOSINGS. DRAWINGS 13.ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY IF DEVICES SHOWN.SWITCHING AND CIRCUITING SHALL BE INDICATED ON
<br /> 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 2. FINISH DOORS,DOOR FRAMES,AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. SEPARATE ELECTRICAL ENGINEERING AS-BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES.
<br /> A)PAINTED WOODWORK TO BE FINISHED NTH ONE(1)COAT PRIMER AND TWO(2)FINISH COATS. 14.ALL TELEPHONE,ELECTRICAL,COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE NTH ALL APPLICABLE 15 SW EVERETT MALL WAY
<br /> 06400-ARCHITECTURAL WOODWORK AND CASEWORK B)SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED NTH A COMMERCIAL GRADE CLEAR STAIN VARNISH. CODES AND REGULATIONS. SUITE D
<br /> 1. CABINET CONSTRUCTION:COMPLY NDH THE A.W.I.ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE"ARCHITECTURAL SPECIFICATIONS MANUAL"(AWS)FOR 15.DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE,ELECTRICAL,AND COMMUNICATION COVER PLATE.OUTLETS EVERETT,WA 98204-2777
<br /> CABINETS SHALL BE FLUSH CONSTRUCTION,LION. PAINT SYSTEMS.LATEX PAINT:AWS SYSTEM 3-B"CUSTOM"(1)COAT PRIMER AND TWO(2)FINISH COATS.GRADE LIGHT COLOR SHOWN GROUPED TOGETHER OR PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE.
<br /> 2. PROVIDE PARTICLE BOARD,MED.DENSITY,WEIGHING S,STAINLESS
<br /> FT.,AT LEAST 3/4"THICK. 16.BACK-TO-BACK OUTLETS ARE NOT PERMITTED.OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL
<br /> 3. CABINET HARDWARE:FULL EXTENSION DRAWER GLIDES,STAINLESS STEEL CABINET PULLS,OR
<br /> FINISH,AND CONCEALED DOOR PAINT FINISH ON GYPSUM BOARD SURFACES. 17.LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION.
<br /> HINGES,SHELF HARDWARE AND OTHER REQUIRED ITEMS,LION IN ELEVATIONS/DETAILS,OR PER BUILDING STANDARD. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS OF THE'ARCHITECTURAL SPECIFICATIONS MANUAL"(AWS) 18,ELECTRICAL ENGINEER TO PROVIDE DESIGN/BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION.
<br /> 4. PLASTIC LAMINATE:HIGH-PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART,NEVAMAR,AND FORMICA,LION.LAMINATE TO FOR PAINT SYSTEMS.LATEX PAINT:AWS SYSTEM 3-B"CUSTOM"(1)COAT PRIMER AND TWO(2)FINISH COATS.GRADE DARK COLOR 19.THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER AND DATA DEVICE.REFER TO DESIGN/BUILD DOCUMENTS FOR SCOPE,
<br /> BE GENERAL-PURPOSE GRADE.050"HORIZONTAL AND 0.030"VERTICAL. PAINT FINISH ON GYPSUM BOARD SURFACES. TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE.
<br /> 5. INTERIOR CABINET SURFACES AND SHELVES TO BE PRERNISHED NTH WHITE MELAMINE,UON. 5. UPON COMPLETION OF WORK,REMOVE EXCESS PAINT,STAIN,VARNISH,ADHESIVE,CAULK,ETC.FROM ALL OTHER SURFACES THAT 20.ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES.COORDINATE EXACT LOCATION NTH FURNITURE VENDOR.
<br /> HERE NOT SPECIFIED TO RECEIVE SAME.
<br /> 6. SHELF EDGING TO BE P-LAM,LION. 21.COORDINATE POWER/DATA,FIRE SAFETY DEVICES&LIGHT FIXTURE MOUNTING LOCATIONS NTH INTERIOR ELEVATIONS,SYSTEM
<br /> 6. TOUCH-UP AND PATCH SURFACES AS REWIRED AFTER THE COMPLETION L WORK BY OTHER TRADES.
<br /> 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECTS REVIEW. FURNITURE,FINISHES&CASEWORK.
<br /> & WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO RI FINISHED,THEY SHALL RECEIVE THE SAME FINISH IO THE ROOM,LION. 22,PROMDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER/DATA DEVICES AND LIGHT FIXTURES. KLV151ON5:
<br /> 8. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE NTH MANUFACTURER'S SPECIFICATIONS(ESPECIALLY IN COORDINATE NTH INTERIOR FINISHES AND CASEWORK.
<br /> DIVISION VII-DOORS AND WINDOWS REGARDS TO THE PRIMING OF EXISTING SURFACES).
<br /> 9. PUTTY ALL NAIL HOLES,COUNTERSUNK SCREWS,BOLTS,CRACKS,ETC.BEFORE APPLYING FINISH. 21CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR 1 219724 CITY COMMENTS
<br /> TO INSTALLATION.INCLUDE GRILLS AND THERMOSTATS.
<br /> 1. PR .
<br /> -WOOD DOORS 10.SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 24RE-CIRCUIT,ALTER OR SEPARATE ELECTRICAL AND VOICE SYSTEM AS NECESSARY AND AS DIRECTED BY BUILDING MANAGEMENT FOR
<br /> 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 11,SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. ALTERED SUITES.
<br /> 2. DOOR SCHEDULE SPECIFICS FINISH(BOTH SIDES OF DOOR)AND FRAME,LION. 12.MAKE FINISH WORK UNIFORM AND SMOOTH,FREE OF DUNS,SAGS,DEFECTIVE BRUSHING AND CLOGGING.MAKE EDGES OF PAINT
<br /> 3. DOORS SHALL BE PRE-MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. 16500-LIGHTING
<br /> 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECTS REVIEW. 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEIUNG PLAN.ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM
<br /> 5. CONTRACTOR SHALL RENEW SUITE FOR DOOR STYLE CHANGES AND VERIFY NTH ARCHITECT AND BUILDING MANAGEMENT THE DOOR DIVISION XII-FURNISHINGS HEIGHT OF 48"A.F.F.OR AS REQUIRED TO MEET THE CURRENT ACCESSIBILITY CODES AND REGULATIONS.
<br /> STYLE TO MATCH IF A VARIATION IS PRESENT. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION,ALL SWITCHES SHALL BE GANGED,UON.
<br /> 12500-WINDOW TREATMENT 3. WHEN WORKING IN PUBLIC CORRIDOR(S)VERIFY SWITCHING REQUIREMENTS NTH BUILDING MANAGEMENT.
<br /> 08710-FINISH HARDWARE 1, ALL EXISTING INTERIOR AND PERIMETER MINI BUNDS TO BE BAGGED AND CLEANED TO LIKE-NEW CONDITION. 4. VERIFY NTH BUILDING MANAGEMENT SEPARATION OF SUITE SWITCHING WHEN DEMISING CONFIGURATIONS CHANGE.
<br /> 1. FINISH AND SPECIALITY HARDWARE INCLUDES ALL ACCESSORIES,TOOLS AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND 2.ALL PERIMETER GAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS.COORDINATE NTH BUILDING MANAGEMENT.MATCH EXISTING 5. DOWN UGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE OR
<br /> MAINTENANCE.ITEMS NOT SPECIFICALLY MENTIONED,BUT NECESSARY TO COMPLETE THE WORK,SHALL BE FURNISHED MATCHING IN CONDITIONS,LION. THE CENTER OF 2x2 PORTION OF 2x4'SECOND LOOK'REGULAR TILE.
<br /> QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 3.ALL INTERIOR SIDELIGHTS TO RECEIVE 1"MINI-BLINDS WERE INDICATED IN DRAWINGS. 6. REUSE ALL EXISTING BUILDING STANDARD FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE
<br /> 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 4.PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS.
<br /> 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS.PROVIDE TWO(2)KEYS FOR EACH LOCK AND 7. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK.
<br /> TWO(2)MASTER KEYS FOR THE SUITE.ALL KEYS TO BE TAGGED NTH ROOM NUMBERS.CONFIRM QUANTITY NTH BUILDING 12900-SIGNAGE 8. ALL OFFICE AREAS LESS THAN 300 SQ.FT.ENCLOSED BY WALLS OR CEUEING-HEIGHT PARTITIONS,AND ALL MEETING AND
<br /> MANAGEMENT. 1. PROVIDE AND INSTALL ALL CODE REWIRED SIGNAGE. CONFERENCE ROOMS SHALL BE EQUIPPED NTH OCCUPANCY SENSORS,PER CODE. PLAN STATUS=
<br /> 4. SUBMIT HARDWARE SCHEDULE NTH CATALOGUE CUT SHEETS FOR ARCHITECTS REVIEW. 9. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS SHALL INDICATE:
<br /> 5. ALL DOORS SHALL HAVE,AT A MINIMUM,1-1/2 PAIR OF BUTT HINGES,ONE LATCH SET OR LOCK SET AND ONE DOOR STOP TO A.CIRCUITING AND WIRING OF LIGHT FIXTURES,AND SWITCHES. PERMIT SET
<br /> MEET ACCESSIBILITY REQUIREMENTS. B.LIFE SAFETY EQUIPMENT.
<br /> 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. C.LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES.
<br /> 7. PROVIDE DOOR CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. D.LIGHT FIXTURE SPECIFICATIONS. JOg NUMBER
<br /> 8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 10.CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR
<br /> 9. SET UNITS LEVEL,PLUMB AND TRUE TO UNE AND LOCATION.ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY TO INSTALLATION. 23-019
<br /> FOR PROPER INSTALLATION AND OPERATION. 11.CONTRACTOR SHALL RE-CIRCUIT AND RE-SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY
<br /> 10.ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY SEPARATE TENANT SUITE FROM OTHERS AND PROVIDE NEW CORRIDOR,HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED.
<br /> UNIT.REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. 12.VERIFY SWITCHING WITH TENANT AND BUILDING MANAGEMENT.VERIFY APPROVED ENERGY CODE REQUIREMENTS OR ENERGY 5CALL:
<br /> 11.PROVIDE PROPER SMOKE GASKETS AT RATED ASSEMBLIES. MANAGEMENT SYSTEM AS PART OF THE DESIGN BUILD CONTRACT. AS NOTED
<br /> 12.MATCH BUILDING STANDARD SPECIFICATIONS AND FINISHES. 13.PROVIDE,ALTER OR VERIFY ALL EMERGENCY EXIT LIGHTING AND ACCESS PATHWAY UGHTING AS DIRECTED BY EXISTING CONDITIONS
<br /> 13.THE FOLLOWING UL LISTINGS ARE REWIRED ON THE FOLLOWING HARDWARE: AND CODE REQUIREMENTS.
<br /> PANIC HARDWARE-UL @305 14.EXIT SIGNS SHALL CONFORM TO UL#924. PLOT DATE
<br /> FIRE EAT HARDWARE-UL#106ı
<br /> ELECTROMAGNETIC LOCI(HARDWARE-UL#FWAX-S-A-6635 2/9/2024
<br /> THE CRASH BAR MUST BE AT LEAST 1/2 OF THE DOOR WIDTH AND OPEN FORCE NO MORE THAN 15 IBS.VERIFY NTH BUILDING STANDARD
<br /> &MANAGEMENT AND INFORM ARCHITECT IF BUILDING STANDARD DOESN'T COMPLY.
<br /> 08810-GLASS
<br /> 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4"TEMPERED SAFETY GAZING,LION. DRAWING TIT!.F:
<br /> 2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS.
<br /> 3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS.GLAZING SUBCONTRACTOR SHALL BE
<br /> RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS.IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN GENERAL
<br /> COMPLIANCE NTH THE STANDARD,THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING SPECIFICATIONS
<br /> NTH THE WORK.
<br /> 4. RATED GLASS(CERAMIC)RELITE SHALL BE PREMIUM POLISHED FINISH.
<br /> 51-1LLT NO:
<br /> A0. 1 B