Laserfiche WebLink
BUILDING CODE SUMMARY D175I6NER <br /> OCCUPANCY TYPE: B(FITNESS CENTER) <br /> EXIST. BUILDING CONSTRUCTION TYPE: II-A <br /> SPRINKLERED: YES t <br /> EXIT FIRE ALARM SYSTEM: YES t <br /> OCCUPANCY SEPARATION: N/A C N S D E S 16 N <br /> i <br /> IMAGINE - DESIGN - DELIVER <br /> PLUMBING FIXT. CALCS CELL:425-941-9494 <br /> \1 FEC PLUMBING FIXTURE CALCULATIONS: <br /> IPER IBC CHAPTER 29 WA STATE AMENDMENTS TABLE 2902.1 REQUIREMENTS: <br /> OCCUPANCY GROUP(B)AREA:33 OCCUPANTSI2=17 PER GENDER <br /> JANITOR'S CLOSET/ � <br /> STORAGE/LAUNDRY REQUIRED PROVIDED <br /> 112 I MALE WATER CLOSETS,1125: 1 1 <br /> 35 SF/300=1 OCCUPAN I MALELAVATORIE$940: 1 1 <br /> FEMALE WATER CLOSETS,1125: 1 1 <br /> FEMALE LAVATORIES,1140: 1 1 <br /> GYM DRINKING FOUNTAINS: 1 2 <br /> 111 <br /> RESTROOM 350 SF/50-7 OC[E]CUPANTS PARKING DATA <br /> 110 <br /> UNOCCUPIED 42'-6" <br /> THE PARKING STALL ALLOCATION FOR THIS <br /> I PROPERTY IS 3.34 SPACES/1000SF.THIS SHOULD FIT <br /> THE REQUIREMENT OF 1 SPACE/300SF FOR HEALTH <br /> CLUBS OR ATHLETIC FACILITIES(3.33/1000SF). Q <br /> LJ 1 <br /> a EGRESS DATA & OCC LOAD <br /> RESTROOM I <br /> Fl-0-9-1 <br /> UNOCCUPIE TRAVEL DISTANCE REQUIREMENTS: <br /> I EGRESS TRAVEL DISTANCE=<300'PER IBC TABLE 1017.2 <br /> SAUNA COMMON PATH OF TRAVEL=<100'PER IBC 1006.3.2(2) <br /> 1 108 <br /> \ I� <br /> OCCUPANT LOAD SUMMARY: <br /> i \ I **EGRESS CALCULATIONS PER IBC TABLE 1004.5 <br /> REFER TO PLAN FOR INDIVIDUAL ROOM OCCUPANT LOADS. <br /> I TOTAL OCCUPANTS=33 <br /> EXISTING ADJACENT TENANT: EXISTING ADJACENT TENANT: NUMBER of EXITS REQUIRED PER IBC TABLE 1006.3.2. 1 PROJECT= <br /> MOLINA HEALTHCARE S18A -0} SAUNA MARINER FINANCE NUMBER OF EXITS PROVIDED: 2 <br /> (B OCCUPANCY) 11 Q7 (B OCCUPANCY) <br /> IEBC ACCESSIBILITY NOTE xoTwoxx <br /> THE COMPLIANCE PATH WILL BE IEBC,CHAPTER 3,SECTION 305 ACCESSIBILITY FOR EXISTING <br /> I BUILDINGS. STUDIO <br /> SAUNAI _ SAUNA 3057 ALTERATIONS AFFECTING AN AREA CONTAINING A PRIMARY FUNCTION 15 SW EVERETT MALL WAY <br /> 104 105 THERE ARE 4 CURRENT ADA ACCESSBILE PARKING STALLS AT THE FRONT OF THE SUITE.ALL SUITE D <br /> SAUNA AREA Y STALLS ARE UP TO CURRENT ADA CODES. EVERETT,WA 98204-2777 <br /> 714 SF/50 = 14 u <br /> OCCUPANTS I PROPOSED SCOPE OF WORK INCLUDES INSTALLATION OF NEW ADA COMPLIANT RESTROOM AND <br /> SHOWER IN RESTROOM#109. <br /> I <br /> 30'-6" REVI51ON5 <br /> SAUNA SAUNA <br /> 102 103 1 2/9/24 CITY COMMENTS <br /> I <br /> I <br /> IRECEPTION <br /> I52 SF/150==1 1 OCCUPANT <br /> WAITINGAREA <br /> 101 <br /> 99 SF/15=7 OCCUPANTS I WAITINGAREA PLAN 5TATU5 <br /> 01 <br /> aT�/'—'Sl <br /> OCCUPANTS PERMIT SET <br /> I FEC J0F)N0M6ER: <br /> 23-019 <br /> SCALE: AS NOTED <br /> EXIST. <br /> PLOT DATE <br /> EXIT <br /> 2/9/2024 <br /> EGRESS PLAN <br /> SCALE:1/4"=V-0" <br /> DRAWING TITLE.: <br /> EGRESS PLAN& <br /> EGRESS LEGEND CODESUMMARY <br /> 5HEETNO: <br /> XX' EGRESS&COMMON PATH&TRAVEL DISTANCE ALONG AO 4 <br /> INDICATED PATH <br /> FEC FIRE EXTINGUISHER CABINET LOCATIONS <br />