Laserfiche WebLink
KEYNOTESD11_5I6NFK: <br /> L1 NO LIGHTS ARE NEEDED ABOVE THE SAUNAS UNLESS OWNER SPECIFIES OTHERWISE. ]r <br /> LIGHTING NOTES CNS DESIGN <br /> IMAGINE - DESIGN - DELIVER <br /> CELL:425-941-9494 <br /> 1. WHENOROBRING LIGHTING PACKAGE IT IS CRFICAL TO SPECIFY CEILING HEIGHT AND TYPE WITH LIGHTING VENDOR. <br /> 2. ELECTRICIAN TO PROVIDE ALL EXIT AND EMERGENCY LIGHTING AS REQUIRED BY CODE. <br /> CEILING NOTES <br /> A. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCES FOR FIXTURES,DUCTS, <br /> PIPING,CEILING SUSPENSION SYSTEM,ETC.,NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON <br /> JANITOR'S CLOSET/ S-1 0" DRAWINGS. <br /> STORAGE/LAUNDRY B. PERIMETER CEILING ANGLE,WHERE OCCURS,SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES,FREE FROM CURVES, <br /> 112 BREAKS OR OTHER IRREGULARITIES AND PAINTED TO MATCH CEILING FINISH. <br /> C. FURNISH AND INSTALL ALL ASSOCIATED TRIM AND SEISMIC BRACING AS REQUIRED. <br /> I <br /> - GYM D. LIGHT FIXTURES,NEW SPRINKLERS AND OTHER CEILING ELEMENTS SHALL BE CENTERED IN THE 2'X2'SECTION OF INDIVIDUAL <br /> 111 CEILING TILES U.O.N.(EXIST.SPRINKLERS TO REMAIN UNLESS CONFLICT WITH NEW ELEMENTS). <br /> OPEN_CEILING E. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE,AND MATCH ADJACENT CEILING FINISH <br /> TO DECK ABOVE U.O.N. <br /> REST.ROQM <br /> Liz]: F. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 46'ABOVE FINISHED FLOOR TO CENTER OF SWITCH U.O.N.MULTIPLE <br /> SWITCHES AT ONE LOCATION SHALL BE GANGED TOGETHER AND FINISHED WITH ONE COVER PLATE U.O.N. <br /> G. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF FINISHED FLOOR TO BOTTOM OF FINISHED GYPSUM BOARD <br /> OR CEILING TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. <br /> H. THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING HEIGHTS,LIGHT TYPES,LIGHT FIXTURES,AND ASSOCIATED <br /> - F ITEMS. <br /> I. IN THE EVENT OF DISCREPANCIES BETWEEN THE DESIGNER'S REFLECTED CEILING PLAN AND LIGHTING PLAN,IMMEDIATELY <br /> NOTIFY THE DESIGNER IN WRITING BEFORE ORDERING MATERIALS OR PROCEEDING WITH WORK. <br /> I <br /> J. NOTIFY DESIGNER OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS,DUCTS,STRUCTURES,HVAC,ANDIOR <br /> (E)CONDUIT,PRIOR TO FRAMING FOR LIGHTS.ANY DISCREPANCIES BETWEEN DESIGNER'S CEILING GRID LOCATION&ACTUAL <br /> FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE DESIGNER PRIOR TO FRAMING. <br /> it SAUNA <br /> 2'-6" 2'-6" ipg K. SUBMIT GRILLE,THERMOSTAT,AND OTHER FIXTURE AND ELEMENT LAYOUTS TO THE DESIGNER FOR REVIEW AT LEAST 2WEEKS <br /> PRIOR TO INSTALLATION. <br /> L. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING,MECHANICAL DUCTS,STRUCTURAL ELEMENTS AND ALL OTHER <br /> RELATED ITEMS.INSTALL NEW PLUMBING,MECHANICAL.FANS,DUCTS,CONDUITS,AND OTHER RELATED ITEMS SO AS TO NOT <br /> CONFLICT WITH ANY/ALL FIELD CONDITIONS INCLUDING LUMINARIES. <br /> m M. INSTALL NEW LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER,LENS,BAFFLE,ETC.TO AVOID FIXTURE <br /> SOILING OR DAMAGE,FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW,ALL LAMPS SHALL BE NEW AT PROJECT PKOJFCT= <br /> COMPLETION-RELAMP EXISTING FIXTURES. <br /> N. GC TO VERIFY CODE COMPLIANCE OF EXISTING ACOUSTICAL CEILING GRID SYSTEMS AND ASSOCIATED SEISMIC BRACING <br /> SAUNASAUNA RESTRAINTS.SYSTEMS FOUND NOT IN COMPLIANCE SHALL BE MODIFIED ANDIOR NEW PROVIDED AS REQUIRED BY CURRENT <br /> 106 BUILDING CODES(INCLUDING,BUT NOT LIMITED TO;CURRENT IBC WALL MOLDING(2'ANGLE)AND SEISMIC SEPARATION <br /> 07 <br /> JOINTS). T <br /> N W R`7�T <br /> 0. GC TO VERIFY CODE COMPLIANCE OF ALL EXISTING LIGHTING FIXTURES AND ASSOCIATED SEISMIC BRACING RESTRAINTS. HO �`ORX <br /> OPEN_CEILING FIXTURES FOUND NOT IN COMPLIANCE SHALL BE MODIFIED ANDIOR NEW PROVIDED AS REQUIRED BY CURRENT BUILDING �rnTTT7O <br /> ANDIOR ENERGY COMPLIANCE CODES. STUDIO <br /> Ll <br /> TO DECK ABOVE <br /> o P. ALL EXITING LIGHTS AND EGRESS LIGHTING LOCATIONS SHALL BE DETERMINED BY BUILDING 15 SW EVERETT MALL WAY <br /> AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. SUITE D <br /> SAUNA m SAUNA Q. ALL SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITHIMCIIBCORSUPERSEDING CODE.ALL FIRE DAMPERS SHALL EVERETT,WA 98204-2777 <br /> 104 105 BE INSTALLED IN ACCORDANCE WITH IMEIIBC OR SUPERSEDING CODE. <br /> R. PROVIDE EGRESS ILLUMINATION FOR IBC 1006.CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THIS SYSTEM AND PROVIDE FULL <br /> COMPLIANCE TO NEW TENANT SPACE. <br /> S. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE(11 LUX)AT THE WALKING SURFACE. <br /> o T. PROVIDE PLAN NOTES TO ADDRESS COMPLIANCE WITH WSEC SECTION 0503.6 AND C405.2 <br /> KFVI51ON5 <br /> U. WSEC SECTION C504.6 REQUIRES LIGHTING CONTROLS FOR ALTERATIONS TO COMPLY WITH C405.2.OCCUPANCY SENSOR <br /> m CONTROLS SHALL BE INSTALLED AS REQUIRED PER 0405.2.1. 1 2/9/24 CITY COMMENTS <br /> SAUNA SAUNA V. DAYLIGHT ZONES SHALL BE DESIGNED SUCH THAT LIGHTS IN THE DAYLIGHT ZONE ARE CONTROLLED INDEPENDENTLY OF <br /> 102 103 GENERAL LIGHTING IN ACCORDANCE WITH WSEC SECTION 405.2.4.1.REFERENCE WSEC SECTION C103.2 <br /> W.COMPLIANCE WITH THE 2018 WSEC FOR LIGHTING REQUIREMENTS WILL BE REVIEWED UNDER THE ELECTRICAL PERMIT <br /> (AREA>2,500 SF) <br /> I <br /> CEILING LEGEND <br /> EXISTING G.W.B.CEILING TO REMAIN. <br /> WAITING AREA I EXISTING WALL MOUNTED LIGHT TO REMAIN. PLAN 5TATU:T <br /> o, RECEPTIO PERMIT SET <br /> 100 7 <br /> A91 NEW G.W.B.CEILING TO BE INSTALLED TO MATCH EXISTING CONDITIONS IN HATCHED AREA <br /> OPEN CEILING 11 JOS NUM6E.K: <br /> TO DECK ABOVE NEW PENDANT LIGHT TO BE INSTALLED AT 144"AFF IF POSSIBLE.SPEC:HYKOUTY,60W LED UFO HIGH 23-019 <br /> X BAY LIGHT 6BOOLM 5000K IP65 WATERPROOF INDUSTRIAL WAREHOUSE HANGING LIGHT;BLACK. <br /> UFO LIGHTS COME AS PART OF THE INTERIOR BRANDING PACKAGE FROM CINEMATION DESIGN; 5CALE: <br /> ELECTRICIAN NEEDED TO INSTALL. AS NOTED <br /> NEW 6"LED RECESSED CAN LIGHT TO BE INSTALLED, PLOT DATE.: <br /> 2/9/2024 <br /> NREFLECTED CEILING PLAN NEW EMERGENCY LIGHT TO BE INSTALLED. <br /> SCALE:1/4"=T-0° 0I NEW LED VANITY LIGHT TO BE INSTALLED. DKAWINC TITLE <br /> p3( NEW EXIT SIGNS TO BE INSTALLED. REFLECTED CEILING <br /> NEW EXHAUST FAN TO BE INSTALLED. PLAN <br /> $ NEW LIGHT SWITCH TO BE INSTALLED. 5HFFT NO <br /> LEGEND NOTES: <br /> 1. LIGHTING INFORMATION IS ILLUSTRATED FOR REFERENCE PURPOSES,ONLY,TO INDICATE <br /> THE DESIGN INTENT. ■ <br />