DESIGNER: <br /> PROVIDE LATERAL BRACING <br /> AS REWIRED TO DECK UNDERSIDE OF EXISTING ROOF <br /> ABOVE,SEE 2/A.9.1. DECK B.O.CEILING <br /> + + + + BACKER ROD AND SEALANT <br /> t L + + APPLY PER MFR. DOOR AS SPECIFIED r <br /> .. RECOMMENDATIONS <br /> MINI COMPRESSION TRACK W/2 <br /> #10 SCREWS ®24" O.C. LIGHT SWITCH: DOTTED INE INDICATES CNS D E S I G N <br /> NEW SUSPENDED ACOUSTICAL o BOST ROOF FRAMING LOCATION OF LARGER PLATE IF NEEDED <br /> 2505125-18 <br /> BLE OR E%ISBNC CMB CENNG 5° g" FOR MORE SWITCHES <br /> I ATTACH CROSS BRACING N ROOF OEC(W/ MAX. 16" O.C. W/5/8" TYPE IMAGINE - DESIGN - DELIVER <br /> FASTENERS(TYP). "X"GWB CELL:425-941-9494 <br /> _ E f THERMOSTAT <br /> CDG. HEIGHT H„IpLL I 2-3/4° <br /> 10'-0" ry, HARDWARE SET AS <br /> ` INSULATION WHERE OCCURS CROSS BRACING AT 4'-0'GC:2-1/2'25 GA EXISTING CEILING SUSPENSION SCHEDULID <br /> SK STUDS ATIAC H W/a6 SHT Mn SCREW. SYSTEM BREAK FOR NEW o 6° NOTE LOCATE ELECTRICAL 8 <br /> WALLS ` <br /> TELEPHONE WALL OUTLETS Q SWITCH <br /> EXIST. MTU. STUD WALLS W/ - - - PLATES®NEAREST STUD FROM <br /> MRL STUD. REFER TO WALL <br /> LEGEND FOR WALL TYPES. (1) LAYER 1/2" TYPE 'X' GWB OTHER LOCATION ON PLAN UNI. <br /> f <br /> ATTACH DROSS BRACING TO RUNNER W/ SHT EA. SIDE m OTHERWISE SPECIFICALLY NOTED. <br /> Mn SCREW. <br /> f5/6'GYPSUM WALL BOARD <br /> 5/8'TYPE'X'GWB EACH SDE OF WALL <br /> EXISTING CONT. MEL. RUNNER DUPLEX QUTIET <br /> ACOUSTICAL BATES WHERE OCCURS <br /> ANCHORED TO FLOOR FIRE EXTINGUISHER CABINET PROVIDE WALL TELEPHONE OUTLET <br /> RUBBER BASE, TYP. BLOCKING PER MANUFACTURER'S REO. <br /> ;FNISH FLOOR <br /> RUBBER BASE PER OWNER FINISH FLOOR AS SCHEDULED <br /> FINISH ROOK <br /> BACKER ROD AND SEALANT <br /> INTERIOR PARTITION 2 PARTITION LATERAL HEAD BRACING 3 PONY WALL DETAIL MOUNTING HEIGHTS DIAGRAM <br /> SCALE:3"=1'-0" SCALE:3"=1'-0" SCALE:3"=1'-0" �J 1/2"=1'-0" <br /> 5/4x MDF TOP CAP-PRIMED&PAINTED <br /> FRY REGET 7 REVEAL <br /> T.O.WALL CAP-tV O'Af.F 12 GA. HANGER WIRE BY 12 GA. HANGER WIRE <br /> a,. <br /> 2x WOOD NAILER 0`T, OTHERS, COMPRESSION POSTS / BY OTHERS, TYPICAL <br /> �P� vP �� USG DRYWALL <br /> SUSPENSION CROSS `'L'�9�SpPa�USG DRYWALLF' �\ SUSPENSION CROSS TEE <br /> GGHT GAUGE FRAMING TOP TRACK I \� \� TET X.0 9, <br /> 2�GA CUP AT EACH SIDE OF POST NIH(2)18 <br /> 1 �o <br /> WS EACH LEG <br /> 5 GWB-PRIME&PAINT ° \ � O PROJECT: <br /> \ \\, <br /> VIBE STEEL WALL BRACE <br /> I suPPaer <br /> 3-5/8'METAL SND WALL PER PLANS 4 LEGEND \ E, 6000� <br /> / SIDES �\��\ \ ofi�,Pe ���� HOTWORX <br /> \ �VOP �\"�p`. P S <br /> Yx2"TUBE STEEL PONY WALL BRACE(SIEELIEC p• �E4"� �� §gyp t STUDIO <br /> E <br /> 0 0 <br /> R 6' <br /> SUPPLY wnLL BRACE suPPaar OR Eau)N s-o _ iso ,y �, <br /> B D.C.a EACH FREE END CH WALL. B 2p��� �� e�s�� \ R� 15 SW EVERETT MALL WAY <br /> y <br /> 9.10 A9.1 — — �gaNC MANSpq�/6A USG ORYWAIL SII�FN90N NIN SUITE D <br /> TEE EVERETT,WA 98204-2777 <br /> \ \\ v <br /> USG DRYWALL SUSPENSION MAIN 7B:/ <br /> WALL BASE PER PLAN _ BIM TRACK GYPSUM BOARD ASSEMBLIES AND THICKNESS MAY HAVE <br /> SET WALL BRACE SUPPORT WITHIN WALL BTM ONLY USE APPROVED EXTERIOR SUBSTRATES AT EXTERIOR SOFFITS,SUCH AS USC DUROCK,FICEROCK, DIFFERENT REQUIREMENTS. REFER TO TECHNICAL INFORMATION <br /> MACKVERIFY WITH YOUR LOCAL USG REPRESENTATIVE PROR TO ISSUING DRAWINGS,TYPICAL REFER i0 ON designstudio.mm FCR ADDITIONAL REQUIREMENTS <br /> FASTEN SnBREC BASE WITH 3/8 0 POWER 9W6o <br /> TECHNICAL INFORMATION ON desi nsm FOR ADDITIONAL REQUIREMENTS <br /> SND SUI EMBEDDED 2 3/8'0 HOES PROVIDED <br /> A]SECTION IN BASE PLATE. ©PLAN ©ELEVATION/SECTION <br /> REVI510N5 <br /> 1 <br /> PARTIAL HEIGHT WALL DETAILS DRYWALL SUSPENSION SYSTEMS 2/9/24 CITY COMMENTS <br /> SCALE:1 1/2"=V-0" SCALE:1/4"=V-0" <br /> PARTITION ISOLATION MOUNT <br /> NEOPRENE ISOLATION BUSHING <br /> UNDERSIDE OF EXISTING ROOF <br /> \ DECK <br /> Schluter.- RENO-V ACOUSTICAL SEALANT FLAN5TATUS <br /> 6'STEEL RUNNER/ PERMIT SET <br /> -� COMPENSATION CHANNEL <br /> Tile or Stone SUSPENDED ACOUSTICAL TILE JOS NUM6ER: <br /> (WHERE OCCURS) 23-019 <br /> TIIe Or Stone 1 SEE RCP FOR HEIGHT SCALE: <br /> AS NOTED <br /> PROVIDE INSULATION(PROVIDE FLOTDATE.: <br /> Substrate <br /> ACOUSTICAL SEALWT AT <br /> BOTH SIDES) 2/9/2024 <br /> 5/8'GYPSUM BOARD BON <br /> SIDES U.O.N. <br /> NIL SND.REFER TO WALL <br /> C7 LEGEND ON A2.1 FOR WALL DRAWINGTITLE: <br /> TYPES <br /> STEEL RUNNER <br /> ACOUSTICAL SEALANT INTERIOR DETAILS <br /> FINISH FLOOR <br /> BOTTOM TRACK WITH PoNER NEOPRENE ISOLATION BUSHING <br /> DRIVEN ATTACHMENT PARTITION ISOLATION MOUNT SHEET NO <br /> ADA TILE TRANSITION @ SHOWER � FULL HEIGHT PARTITION A9. 1 <br /> \� SCALE:NTS SCALE:3"=1'-0" <br />