My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4030 RUCKER AVE 2022 Plans 2024-07-08
>
Address Records
>
RUCKER AVE
>
4030
>
Plans
>
4030 RUCKER AVE 2022 Plans 2024-07-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2024 12:54:48 PM
Creation date
7/8/2024 12:53:17 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4030
Permit
S2206-005
Year
2022
Notes
INSTALL NEW ILLUMINATED AM/PM SIGN - REMOVE EXISTING AM/PMs
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2'' <br /> FORMED <br /> • 1/2"EMBOSSMENT FACE itSignResource <br /> C Fuel Price Sign BACKGROUND <br /> 'h"Eh1BOSSfdENT I ll 1:A'I'I'I'1 C:It(T t I' <br /> SPARK <br /> 6135 District Blvd•Maywood,CA 90270 <br /> B00.423.4283•Fax 323.560.7143 <br /> Website:www.signresource.com <br /> MID — Proposed I REVISION HISTORY: <br /> r -;�.'At' SPOtTeD <br /> W 09/02/22 O P. D.Q. <br /> 4 64"CABINET SIZE ► RErKInNtESA.=.IPPON <br /> INITIAL DRAWING RELEASE <br /> it 621/2"TRIM SIZE . 4 10" > DETAIL A <br /> 4 59 5/8"FORMING AREA > 21/4"-* 4- * 4-2 1/4" <br /> 56 5/B" 1 <br /> PARTS LIST: <br /> ARCO A ItEM DECORATION <br /> \ I / a PMS 288C <br /> E PMSWHITE <br /> DETAIL A( ' E P OUT <br /> o PEARLARL <br /> ' <br /> E PMS 485C _..._...!• <br /> Wig i6 F DIGITAL PRINT 1111 <br /> MATERIAL LIST <br /> 1 PLASTIC FACE <br /> s ALUMINUM CABINET <br /> NIGHT ILLUMINATION VIEW 203/4" SECOND SURFACE DECORATION <br /> 14- rD <br /> 39 5/8" NOTE:WEIGHTS AND MEASURES <br /> - Weigh5 and Measures requirements vary by Slole,County <br /> _ �' and Municipality.D is the responsibility of the lomer to <br /> i t / 0 0 EO 60" 581/2" 55 5/8" confirm that these graphics are compliant with all imut <br /> CABINET TRIM FORMING ♦ Regulations,Statues and Ordinances.Complionry must be <br /> confirmed by the party obtaining the permit.SignResource is <br /> 1 not liable for misinterpretation of local Weights and <br /> HI' 63/C O E SIZE SIZE AREA Measures requirements or any rule changes that may occur <br /> after the order has been placed. <br /> 07 0 ° ARCO9 7/16" f pe miffing and immllation is provided by SignRe ourte, <br /> wewill makeeveryse rttoconfirmthesignoge provided is <br /> ,, compliant at the lime of installation. <br /> 120v ELECT',...FEET THIS SIGN I INTENDEDWI TO BE INSTALLED IN <br /> ACCORDANCE WITH THE REQUIREMENTS OF <br /> ATTACHMENT DETAIL ARTICLED/DR60 OF THE IC ELECTRIC <br /> r AND/OR OTHER APPLICABLE LOCALCODES.DE <br /> DETAIL B THIS INCLUDES PROPER GROUNDING AND <br /> BONDING OF THE SIGN <br /> -• a3`MBOT ' I GENERAL NOTES <br /> h"EMBOSSMENT d)AT <br /> BACKGROUND F <br /> 12" LiOLERAN(E(UNLESS fID1ED) <br /> „-. 1:.-+ is__ •GRAPHICS-/-t/8"•FACE SAL+l/16'-1/4" <br /> •CABINET+/-1/8'•VIM OVERLAP+1/8"+/1/16" <br /> •ALL COPY LEVEL UNLESS NOTED OTHERWISE <br /> 2.VIEWING DISTANCE 25'TO 50 UNLESS NOTED OTHERWISE <br /> 410 3.PMS COLOR CULLOUT INDICATES USE OF SPRAYIAT MIX SYSTEM <br /> �r / - 4,NO DEVIATION OR MATERIAL SOBSTIIDaON WITHOUT KN. <br /> S.ALL ELECTRICAL SIGNS TO COMPLY WITH UL 48 <br /> - PLATE ATTACHMENT INSIDE CABINET - <br /> I. <br /> 5'X 5' APPROX. <br /> FRONT VIEW SIDE VIEW ILLUMINATED DOUBLE FACE <br /> DETAIL B CENTER POLE SIGN <br /> SCALE 1" = 10" ,: eamn meeL,: uEif1CZ <br /> sunea, (HEMP. <br /> Please Note:Weights and Measures requirements vary by State,County and Municipality.It is the responsibility of the customer to confirm that these graphics are compliant with all local Regulations,Statues and Ordinances. mmt. DOMCHE S.PATFERSON <br /> Compliancy must be confirmed by the party obtaining the permit.SignResource is not liable for misinterpretation of local Weights and Measures requirements or any rule changes that may occur after the order has been placed. By signing,you are validating the dimensions and graphic provided ARCO <br /> to SignResource and/oryou are handingyour own installation. "` <br /> If permitting and installation is provided by SignResource,we will make every effort to confirm the signage provided is compliant at the time of installation. 9 2956431/22516 EVERETT,WA <br /> quote: mit <br /> INFORNUION BAR KIT IART NUMBER PART NUMBER PAGE NUMBER I QUOTE 369542 09/02/2022 <br /> OUDNOPoAI a ZEV. <br /> THIS IS A KIT PART ORDER AMZLED0005MM-KIT 1AMZP60X64E01 2 OF 6 369542 1AMZP60X64E01 A <br /> Project Name Site # Customer Created by <br /> Permit Pack <br /> ARCO — AMPM & 2T 83367 ARCO JS PROJECT CSI <br /> Orlg-05-13-22 <br /> Revision # R2-06.16-22 Date Scale Page # 12690 Ford Drive <br /> R3-02-16-23 <br /> Fishers, IN 46038 <br /> S R4 04-20-2023 NA 11 of 13 www.projectcsi.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.