My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3315 SEAWAY BLVD 2024-07-16
>
Address Records
>
SEAWAY BLVD
>
3315
>
3315 SEAWAY BLVD 2024-07-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/16/2024 8:13:43 AM
Creation date
7/15/2024 11:16:48 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3315
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4a=)1` COMMISSIONING, START-UP & 1ST <br /> MacDonald-Miller INSPECTION REPORT <br /> FACILITY SOLLTIONS <br /> page of <br /> JOB NAME: TERRA POWER JOB# 72236307 DATE: 4/512024 CONTACT: Steve S/Devon E <br /> JOB SITE ADDRESS: 3315 SEAWAY BLVD EVERETT WA PHONE NUMBER: <br /> NEW INSTALUREPLACE/EXISTING? NEW PROJECT MGR: Joe Brucker TECHNICIAN: Phil R <br /> UNIT REMOVAL INFO REFRIGERANT TYPE: AMOUNT OF REFRIGERANT: METHOD OF DISPOSAL&PO#: <br /> OLD INDOOR MODEL# OLD MAKE: OLD S/N: <br /> OLD OUTDOOR MODEL# OLD MAKE: OLD S/N: <br /> OLD INDOOR UNIT DESIGNATI OLD OR CODE#: -D OUTDOOR UNIT DESIGNATIO OLD OR CODE <br /> UNIT TYPE: Indoor&Package) Package rooftop MAU UNIT TYPE:Outdoor,CU,HP,VFD SPLIT SYSTEM ONLY.., <br /> NIT NUMBER/MAKE DOAS-R-1/Greenheck NEW OR CODE: AA013616 UNIT NUMBER: NEW OR CODE: <br /> MODEL#: IGX-P120-H32-MF-P MAKE: <br /> SERIAL#: 24017273 MODEL#: <br /> NAMEPLATE VOLTAGE/PHASE: 460 I 3 SERIAL#: <br /> ACTUAL VOLTAGE/PHASE: 489/4881489V 1 3 NAMEPLATE VOLTAGE/PHASE: I <br /> TONNAGE: TOTAL UNIT UNIT RATED AMPS: 10.7 TXV OR ORIFICE: ACTUAL VOLTAGE/PHASE(A,B,C): I <br /> HEAT TYPE: Gas LOCATION: Rooftop-center LINE SIZES:SUCTION: LIQUID: Refer bottle S/N: <br /> TRANSFORMER SECONDARY VOLTAGE MEASURED: REFER TYPE:R- QUANTITY:CKT A: CKT B: <br /> FILTERS: QTY SIZE TYPE <br /> 10 20X25X2 Disposable <br /> 6 Pre-filter mesh Washable NOTES: <br /> BELTS:NA QTY SIZE QTY SIZE MAU has 2 furnace sections,SAT and OAT sensors integral to unit and displayed through controller.Jumpered R to G <br /> terminals and Enabled unit with 70SAT STPT.ATS might change BO-11 location from U9 to R-G for unit enable.Fire <br /> alarm may also wire NC contact in series for unit shutdown. <br /> UNIT LABELED Y MMFS STICKER INSTALLED Y HVAC UNIT DEMO&RECOVERY FORM Na <br /> WIRING CONNECTIONS TIGHT Y CONDENSATE TRAP INSTALLED Na SHIPPING BLOCKS/BOLTS REMOVED Na <br /> ECONOMIZER OPERATION CHECKED Y ADEQUATE FUSED DISCONNECT Na PROPER FUSES INSTALLED Y <br /> START-UP LABEL WITH JOB#IN UNIT Y DEFROST ON HEAT PUMP CHECK Na VERIFY BELT TENSION/ALIGNMENT Na-DD <br /> CONDENSATE PUMP INSTALLED Na CONDENSATE PUMP OPERATIONS Na FAN/PUMP ROTATION VERIFIED Y <br /> CONTROLS: DDC CONTROL SYSTEM: Alerton MMFS PROGRAMMED: MAKE: MODEL: <br /> PC LOCATION: PASSWORD ACCESS: PERSON TRAINED: Mike Green ATS pm.Used as a Reference only. <br /> SMOKE DETECTOR: DESIGN MINIMUM&MAX PRESS: MEASURED AIR PRES.: STANDALONE: BUILDING SYSTEM: <br /> SMOKE DETECTOR WORKS CORRECTLY: Not wired at startup.Andy SMOKE DETECTOR model#: Existing or New: <br /> FAN SHAFT <br /> FAN/PUMP:direct drive NAMEPLATE AMPERAGE: 6.8a MEASURED AMPS(A,B,C): 6.1/6.216.2A MOTOR FN#: 184T SIZE: Na <br /> FAN PULLEY <br /> HP: 5 SPEED/RPM: 1750 CL BETWEEN SHAFTS: Na MOTOR PULLEY SIZE: Na SIZE: Na <br /> OUTDOOR FAN: NAMEPLATE AMPERAGE: MEASURED AMPS(A,B,C): HP: <br /> COMPRESSOR A: MEASURED VOLTS(A,B,C): NAMEPLATE AMPS: MEASURED AMPS(A,B,C): <br /> LIQ PRESS: <br /> Hot Gas Bypass: SUCT PRESS:CLG: HTG: CLG: HTG: Comp.Disc.Line Temp:C: H: <br /> EVACUATED: SUPh:C: H: SUBc:C: H: RAT:C: H: SAT:C: H: AT:C: H: <br /> ENTHALPY <br /> AIR/WATER INLET TEMP:C: H: AIRMATER OUTLET TEMP:C: H: OUTDOOR TEMP: SETTING: <br /> COMPRESSOR B: MEASURED VOLTS(A,B,C): NAMEPLATE AMPS: MEASURED AMPS(A,B,C): <br /> LIQ PRESS: <br /> Hot Gas Bypass: SUCT PRESS:CLG: HTG: CLG: HTG: Comp.Disc.Line Temp:C: H: <br /> EVACUATED: SUPh:C: H: SUBc:C: H: RAT:C: H: SAT:C: H: AT:C: H: <br /> GAS HEAT: NAMEPLATE MANIFOLD PRESSURE: 3.5' MANIFOLD PRESSURE AT FIRE: BOILER(yes or no): <br /> INDUCER MOTOR RATED AMPS: 1.3/.35A INDUCER MOTOR MEASURED AMPS: 1.3/.3A RETURN TEMP: OAT=50F SUPPLY TEMP: 110 AT: 60 <br /> IGH LIMIT SETTING: TEST HIGH LIMIT?: FLAME ROLL OUT?: PRESSURE SWITCHES?: <br /> NAMEPLATE <br /> ELECTRIC HEAT: MFG: Model-#: SERIAL#: KW: :\T: <br /> MEASURED VOLTS A,B,C: NAMEPLATE AMPS: MEASURED AMPS(A,B,C): TEST HIGH LIMIT? <br /> REMARKS: <br /> Safeties tested opening circuits.Outlet gas pressure regulators set to 9"wc.Manifold pressures between 3.5-5"we per nameplate.Isolation damper at unit inlet verified.Yaskawa vfd for supply fan factory set.Sequence of <br /> operation-BAS to control fan based on building pressure Setpoint and possibly determined by TAB.Supply air temp to be set at unit controller. <br /> 6/16/23 rev <br /> 1 <br />