Laserfiche WebLink
MICROINVERTERS SPECIFICATION PV MODULE RATING A STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8, Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 0 <br /> MICROINVERTER MODEL NO. DS3-L 310.16, Chapter 9 Table 4, 5, &9. Locations specific BUS BAR RATING X 120%) - MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p infinity <br /> solar <br /> AC OUTPUT 768 W temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA 98661 <br /> PHONE:1-800-818-0598 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP 5°CINFINITY SOLAR.COM <br /> AMBIENT TEMP HIGH TEMP 2°/ ° THIS PANEL IS FED BY MULTIPLE SOURCES <br /> MODULE: (06) ZNSHINESOLAR ZXM7-SH108-410M NOM.MAX.POWER AT STC(PMAX) 410 WATT ( �) 26 C UTILITY AND SOLAR)) REVISIONS <br /> INVERTER: (03)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V CONDUIT HEIGHT 7/8" Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C AC OUTPUT CURRENT 10A Initial Design 4/9/24 00 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT CONDUCTOR TEMPERATURE RATE 901C NOMINAL AC VOLTAGE 240V <br /> WITHIN 10' OF UTILITY METER NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED <br /> NOTE : WITHIN 3FT OF AC DISCONNECT. POINT OF INTERCONNECT, LOAD SIDE Signature with Seal <br /> S <br /> ATTIC RUN -YEEXISTING 240V/200A BUS BAR RATING, <br /> SHUTDOWN - ES MAIN SERVICE PANEL,SINGLE PHASE, <br /> WITH A 200A MAIN BREAKER <br /> UTILITY COMPANY-SNOHOMISH <br /> COUNTY PUD <br /> UTILITY METER#911536 <br /> EXISTING <br /> BI-DIRECTIONAL Project Name& <br /> (N) 125A COMBINER PANEL, (N)BLADE TYPE M UTILITY METER, Address <br /> 240V,3W,1-PHASE NON-FUSIBLE AC DISCONNECT 1-PHASE,3W, <br /> NEMA 3R 30A-2P 120/240VAC 120V/240V <br /> (VISIBLE, LOCKABLE, LABELED) U <br /> 200A E--{ o LU <br /> (E)jO\S w Q < Q Q <br /> � z Z <br /> r1 <br /> (06)ZNSHINESOLAR ZXM7-SH108-410M (N)PV BREAKER U z a <br /> (03)AP SYSTEMS DS3-L INVERTERS (N)JUNCTION BOX 20A 2P z Lo 5; LU <br /> LU Oz w <br /> 600 V, NEMA 4 L1 a- <br /> BRANCH 1 -06 MODULES WITH 03 MICRO INVERTERS UL LISTED 15A N w <br /> L2 r� <br /> a <br /> Y <br /> L1 L1 G <br /> L2 L2 <br /> ---------- ----- ----- <br /> -- ----- ----- - <br /> G G <br /> -- — �— -- ---- — $ J <br /> _J L J L J L Sheet Name <br /> -- 3-LINE <br /> __________ _--------_ _______J EXISTING GROUNDING DIAGRAM <br /> 1 2 3 3 ELECTRODE SYSTEM <br /> Sheet Size <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPE\AMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. GND LENGTH VOLTAGE 11" X 17„ <br /> TAG# DEVICES RATING MULT CURR X125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT FT. MAX DROP(/o) <br /> Sheet Number <br /> 03 x 3.20 x N/A = 9.60A 12.00A #10\THWN \40A @90°C 15A 2 TRUIN AIR NK BLE 1.00 x 1.00 x 40A 40.00A <br /> 9.60A #6 AWG 20 0.28 E 1 .1 <br /> O 03 x 3.20 x N/A = 9.60A 12.00A #10\THWN \40A @90°C 15A 2 3/4" EMT 1.00 x 1.00 x 40A 40.00A 9.60A #8 AWG 35 0.48 0.93< <br /> 2 <br /> O03 x 3.20 x N/A = 9.60A 12.00A #10\THWN \ 35A @75°C 20A 2 3/4" EMT 1.00 x 1.00 x 35A 35.00A 9.60A #8 AWG 10 0.17 <br />