Laserfiche WebLink
IN140®41 <br /> \ WSU Cougar Pride Sculpture Date: 2/5/2024 <br /> A� r`'ss'e it <br /> By: Brett Danielson <br /> ` lose. 915 North Broadway Avenue <br /> Tapio Office Center,Green Flag Building Page: 10 of 11 <br /> 104 South Freya Street,Suite 110-F,Spokane,WA 99202 Foundation Design <br /> (509)532-1532 Voice and Cell,(509)534-0664 Fax Project No.: 2020077.1 9 <br /> Perimeter Footing Loads: <br /> Roof Span = 5 feet Overhangs = 0 feet <br /> Level Pressures (psf) Tributary Wall Load (lbs.per ft.) <br /> (1DEAD LOAD gLIVE LOAD portion, b (ft)I(J)DEAD LOAD I ())LIVE LOAD (J)TOTAL LOAD <br /> Roof Loads: 101 20 2.50 252.50 50.00 302.50 <br /> Walls: 89 0 9.00 801.00 0.00 801.00 <br /> Wall Loads At Top Of Foundation, (OWOOD =17053.50 50.00 1103.50 <br /> Top of Foundation Geometry: <br /> Width = 5 feet Thickness, tsLAB = 4 inches Toe Depth, hTOE = 0.333 feet <br /> Side of Foundation Geometry: Key Depth, dKEY = 0 inches <br /> Wall Thickness, twALL= 6 inches Wall Height, hwALL= 42 inches <br /> Footing Width, wnG = 24 inches / Footing Height, hFTG = 6 inches <br /> Wall Loads, gWALLCONC = YCONC[(tWALL)(hWALL)+(tFTO)(hFTO))/12 <br /> 155 x ( 6 x 42 + 24 x 6 ) / 144 = 426.3 lbs. per foot <br /> Wall Loads At Base Of Footing, wFro = 1479.75 50 1 1529.75 <br /> Retained Height, hRETTAINED = -3 feet Allowable Toe Pressure = 5000 psf <br /> Heel Width, WHEEL= 9 inches Toe Width, wTOE = 9 inches <br /> Required Width, bFTG = o)FrG/QALLOWABLE = 1530 / 5000 = 0.306 feet O.K. <br /> Soil Height, hsOIL= -2.17 feet Span = 3.333 feet <br /> MU = 1.7 x 0 = 0 ft-lbs. per foot of width <br /> Side of Foundation Reinforcing: <br /> Use: 6 inch thick wall with inner reinforcing at 2.5 inch cover <br /> Factored Axial Load, PU =YDEAD((ODEAD LOAD) + YLIVE((OLIVE LOAD) (Section 1909.2.1, Equation 9-1) <br /> 1.4 x 1480 + 1.7 x 50 = 2156.65 plf Pu_MIN = 1332 plf <br /> Po = 0.10(fc)AG = 0.1 x 2500 x 6 x 12 = 18000 lbs. per foot of width <br /> Strength-reduction factor, 0 = 0.9 - 0.2 (PU)/Po (Section 1909.3.2) <br /> 0.9 - 0.2 x 2156.65 / 18000 = 0.876 <br /> Use: # 4 reinforcing ABAR = 0.2 sq, in. = 0.133 sq. in./ft. dBAR = 0.5 in. <br /> d = 6 - 2.5 - 0.5 / 2 = 3.25 in., Bar spacing, b = 1S in. <br /> a = (PU_MIN+ABAR/FTfY)/10.2fc - (1 Curtains) <br /> _ ( 1332 + 0.133 x 36000 ) /( 10:2 x 2500 ) = 0.24 in. <br /> Factored Nominal Moment Capacity, WN = VPU_MIN+(ABAR)fy(12)/b)[d - a/21 <br /> 0.876 x ( 1332 + 0.133 x 36000) x ( 3.25 - 0.24 / 2 ) <br /> 16812.07 inch-lbs. = 1401.005 ft.lbs. per foot of width O.K. <br />