My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-54 2024-10-24
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-54
>
3003 W CASINO RD BLDG 40-54 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 11:30:27 AM
Creation date
7/24/2024 10:15:59 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-54
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I �I <br /> I <br /> N W N W cV W <br /> 6 <br /> l — <br /> x x x X <br /> XC[ <br /> 2 <br /> R2"x16 0 <br /> 5-12 5-12 5-112 5-12 -102 <br /> e o 5 Q o DN. 2"x12-6 <br /> HYDRAULIC CALCULATIONS <br /> 4"x2"J Q <br /> VMT REMOTE AREA: OUTDOOR (DOUBLE ROW) <br /> _ <br /> w FILE No.: OUTDOOR RACK.SDF <br /> TOR DENSITY: 30 GPM/HD. <br /> I 7a BOR HOSE DEMAND: 500 GPM <br /> P5-651 REVER5I131-E CHNL.BRKT. I EX. DRY RISER MAX SO FT PER HEAD: EVERY TRANSVERSE FLUE <br /> ATTACH TO 22 GA.5HT.MTL (SV-54-14) TOTAL HEADS FLOWING: ENTIRE RACK (5 HDS) <br /> K-FACTOR: 11.2 <br /> (4)315"x 11/4"HEX BOLT w w w END HEAD PRESSURE: 30 GPM <br /> W/3/5"FLAT W5HR. PRESSURE AT B.O.R.: 33.9 PSI <br /> HANGER#2 1 _ <br /> E.5 FLOW AT BASE OF RISER: 156.0 GPM <br /> C SAFETY FACTOR: 38.5 PSI <br /> SHEET METAL CANOPY(22 GA.) SCOPE OF WORK: <br /> ATT(6r OMETATop <br /> coSTTRUT SUPPORT <br /> R INSTALL SPRINKLERS IN NEWLY RELOCATED DOUBLE-ROW RACKS. <br /> (TOPSTBOEING PIPESrRUc RT) _ CONNECT TO THE EXISTING DRY SYSTEM,RISER SV-54-14. <br /> -DRY-PEND. - DESIGN: <br /> DESIGN PER BOEING 909 SUBMITTAL DRAWING M514,DATED 10.19.2023,CONSTRUCTION NOTES. <br /> — NOTE 14,GENERAL PALLET RACK SPRINKLER REQUIREMENTS: <br /> SPRINKLERS SHALL BE ARRANGED IN FLUE SPACES PER FM GLOBAL DATA SHEET 8-9, <br /> FIGURE 9,"PLAN VIEW OF IRAS(EO) IN-RACK SPRINKLERS». DEFLECTORS SHALL BE LOCATED <br /> 36" MINIMUM FROM TOP OF STORAGE COMMODITY. <br /> _ NOTE 16, HYDRAULIC DESIGN: <br /> MINIMUM 30 GPM/HEAD, (8)SPRINKLERS,500 GPM HOSE,DO NOT BALANCE RACK DEMAND <br /> WITH CEILING DEMAND, DO NOT EXCEED 20 FT/SECOND VELOCITY,FM GLOBAL APPROVED <br /> /. /. DRY PENDENT SPRPINKLER,K11.2 OR LARGER,285F TEMPERATURE RATING. <br /> FITTER NOTES: <br /> UNI.Smut EXTENSIONS TO ENSURE / / — — — E"6 1)ALL NEW PIPING SHALL BE SCH.40,BLACK. <br /> MIN aB'CLEARANCE BETWEEN TOP / 2)ALL FITTINGS FOR 12' &SMALLER PIPE SHALL BE THR'D MALLEABLE IRON, BLACK. <br /> OF TALLEST COMMODITY TO <br /> SPRINKLER DEFLECTOR / FITTINGS FOR 22'AND LARGER SHALL BE VICTAULIC GROOVED,ORANGE FINISH. <br /> FITTINGS FOR 7' PIPE MAY BE EITHER M.I. BLACK,OR VICTAULIC GROOVED. <br /> sa s) 3)ALL GROOVED COUPLINGS SHALL BE VICTAULIC STYLE 07"ZERO-FLEX". <br /> / 4)ALL NEW HANGERS SHALL BE PER DETAILS,SPACED PER NFPA-13. <br /> 5)HYDRSTATIC TEST:225 PSI FOR 2 HOURS. <br /> RACK SUPPORT RACK SUPPORT ,2 o� o4x2 VMT �,-- <br /> POC DN. 2"x12-6 <br /> - O2" O �„ 3 2„ O 2'1 5 2" <br /> � <br /> - - - 3-1021 RN. 2"x16-0 <br /> 1A 2A 3I4 4A 5P <br /> DV2 � <br /> j w w w O 1 3 5 7 <br /> / EX.6"RELIABLE A <br /> RACK UPRIGHTS DRY VALVE <br /> so 1 Dv, _ ii ® © T <br /> / I IT ST-41 ME] <br /> ® o I� <br /> I I E <br /> AFF BOR EI-=E=,E OEE]: <br /> FP1 oft <br /> 2, 1, FR D_D. <br /> O <br /> north FIRE PROTECTION PLAN EXISTING DRY RISER SV-54-14) north <br /> DOUBLE—ROW RACK CROSS SECTION 1 KEY PLAN <br /> 1/T-1'-0' 3/1G'=1'-0' (OUTDOOR DOUBLE-ROW RACK) 1/2'=1'-0' (LOOKING SOUTH) SCALL:NONE <br /> ABBREVIATIONS SPRINKLER LEGEND WATER SUPPLY INFORMATION REVISIONS STAMP PROJECT <br /> W AFF-CENTERLINEABOVEFINISH FLOOR SYMBOL MAKE MODEL SME S.I.N. TEMP. N.P.T. K-FCTR. CANOPY FINISH TOTAL STATIC: NO. DATE BY DESCRIPTION ��� Boeing 40-54 Building <br /> BFC-CENTERLINE BELOW FINISH CEILING qp� onoN�� <br /> BOB-CENTERLINEBELOWBOTTOM IF3EAM VIKING ESFR PENDENT VK510 155° 1" 25.2 N/A BRNZ. 0 RESIDUAL: Ql 3003 W.Casino Rd. <br /> BOC-CENTERLINE BELOW BOTTOM OF CHANNEL BIN BFIRE PROTECTION <br /> BOD CENTERLINE BELOW BOTTOM OF DECK ® VIKING ELO DRY PEND. VK547 286° I" 11.2 N/A BRNZ. 10 FLOWING: 0 201L—W3 Everett,WA.98204 <br /> BOJ-CENTERLINE BELOW BOTTOM OF JOIST W"/A1110-6. TC_V_y <br /> BOP-CENTERLINE BELOW B070M OF PURLIN DATE: 0 VROK&S373NT VIKING AUTOMATIC SPRINKLER COMPANY <br /> N BTJ-CENTERLINE BELOW TOP OF JOIST 3434 FIRST AVENUE SOUTH <br /> S LOCATION: 0 53&ktf 12/4/23 ..u.,, <br /> coJ-curoNJoe ,.,, PORTLAND SEATTLE,WA.98134 LONGVIEW <br /> DOEGROOVEONE END PROVIDED BY: Q --- SETTLE PHONE:206 622-4656 FAX:206 622-9319 MERIDEAN In-Rack Protection <br /> TOE-THREAD ONE ENO ...-.-r..----..--------- ( ) ( ) <br /> SEATTLE POCATELLO <br /> G-G-Gfl00VEx GROOVE FIRE PUMP INFORMATION Q CCBO p:VIKINAS373NT <br /> T-G-THREADx GROOVE <br /> T-T-THREAD xTHREAD PUMP TYPE: 0 N: SHEET <br /> DRAvmev: GC SHEET NUMBER <br /> N.I.C.-NOT IN CONTRACT THIS DRAWING IS THE PROPERTY OF VIKING AUTOMATIC SPRINKLER COMPANY. <br /> POC-POINT OF CONNECTION TOTAL SPRINKLER THIS SHEET: 10 RATED PRESSURE: APPROVING AUTHORITIES IT IS SUBMITTED IN CONFIDENCE AND IS NOT TO BE DISCLOSED ORUTILIZED FP2of2 <br /> E 0O.L.:GROOVEOUET(GROOVED WELDED OUTLET) WITHOUT THE WRITTEN PERMISSION OF VIKING AUTOMATIC SPRINKLER BCPLE: PRaECTNUMBER: <br /> P.O.L.PIPED-LETQHREADEDWELDED <br /> WELDED <br /> TOTAL SPRINKLERS THIS PROJECT: 64 RATED Boein Fire&The Cit of Everett Noted WO-10535 <br />
The URL can be used to link to this page
Your browser does not support the video tag.