My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-54 2024-10-24
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-54
>
3003 W CASINO RD BLDG 40-54 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 11:30:27 AM
Creation date
7/24/2024 10:15:59 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-54
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sprinkler 124d January 17, 2014 <br /> C <br /> ESFR PENDENT <br /> SPRINKLER VK510 (K25.2) <br /> -NIKJNG4 <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> DESIGN CRITERIA- UL <br /> (also aaalies for the ESFR Cold Storage System) <br /> (Also refer to Approval Chart 1 on page 124c.) <br /> cULus Listing Requirements: <br /> ESFR Pendent Sprinkler VK510 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest appropriate NFPA stan- <br /> dards(including NFPA 13)for ESFR Pendent K25.2(363)Sprinklers,for: <br /> • Protecting rack storage of certain specified materials up to 40 ft(12.2 m)high in buildings with 45 ft(13.7 m)high ceilings with NO in-rack sprinklers. <br /> • Exception to NFPA 13 sprinkler installation rules for ESFR Pendent K25.2 Sprinklers: <br /> cULus Listing Requirement for Buildings up to 40 ft.(12.2 m)High:Locate the deflector between 6"and 18"(152 and 457 mm)below the ceiling. <br /> cULus Listing Requirement for Buildings Between 40 ft.(12.2 m)and 45 ft. (13.7 m) High: Locate the deflector between 6"and 14"(152 <br /> and 356 mm)below the ceiling. <br /> • The minimum area of coverage allowed per sprinkler is 64 ft'(5.8 m2)per NFPA 13. <br /> Maximum Roof or Ceiling Slope: 2 in 12(167 mm/m or 9.5 degrees). <br /> Sprinkler Position:Approved for use only in the pendent position.Align the deflector parallel with the ceiling or roof. <br /> System Type:Wet systems only. <br /> Deflector Distance from Walls:At least 4"(102 mm)from walls,and no more than one-half the allowable distance permitted between sprinklers. <br /> Clearance from Deflector to Top of Storage:At least 36"(914 mm). <br /> Maximum Distance Between Sprinklers:The maximum area of coverage allowed per sprinkler is 100 ft'(9.3 <br /> • For buildings over 30 ft(9.1 m)high,spacing between sprinklers and/or branch lines must be from 8 to 10 ft(2.4 to 3.1 m)**. <br /> • For building heights up to 30 ft(9.1 m), the spacing allowed between sprinklers and/or branch lines is 8 to 12 ft(2.4 to 3.7 m), provided the <br /> area covered per sprinkler does not exceed the maximum 100 ft2(9.3 m2)allowed**. <br /> **Refer to the Installation Standards for permissible deviations from the maximum sprinkler spacing rules above,to eliminate obstructions created <br /> by trusses and bar joists when using ESFR sprinklers. <br /> Note: If the ceiling is beam and girder or panel construction, locate sprinklers in the bays rather than under the beams. <br /> ESFR Cold Storage System <br /> Viking ESFR Sprinkler VK510 is also cULus Listed for use with a maximum 50%by volume factory premix propylene glycol and water antifreeze solu- <br /> tion.This Listing is based on full-scale fire testing at Underwriter's Laboratories.The following limitations of system design and application shall apply: <br /> Storage Arrangements: Solid-piled,or open rack(single, double, multiple, or portable), palletized storage(pallets limited to wood),with no open-top <br /> containers or solid shelves. <br /> Commodity Classification: Limited to Class II or less. <br /> Maximum Storage/Ceiling Heights and minimum pressure requirements: <br /> • Storage height up to 35 ft. (10.7 m) with ceiling height up to 40 ft. (12.2 m) with a minimum system design pressure of 40 PSI (2.76 Bar). <br /> OR: <br /> • Storage height up to 40 ft.(12.2 m)with ceiling height up to 45 ft-3 in.(13.8 m)with a minimum system design pressure of 60 PSI (4.14 Bar). <br /> Maximum System Volume of the Antifreeze Water Solution: Limited to 1,100 gallons(4 163 liters). <br /> Minimum Temperature: -21 OF(-29.4°C). <br /> Maximum Percentage by Volume of Propylene Glycol: 50% mixed with water for antifreeze solution. <br /> • Where the minimum temperature in the area being protected is 8 OF (-13.3 °C) or above, 35% percent by volume of propylene glycol factory <br /> premixed with water must be used.Viking requires Firefighter Eliminator C premix 35%propylene glycol/water mixture with a freeze temperature <br /> rating(freeze point)of 2.4 OF(-16.4°C). <br /> OR: <br /> • Where the minimum temperature in the area being protected is between 8 OF (-13.3 °C) and -21 OF (-29.4 °C), the percentage by volume of <br /> propylene glycol must be 50%, factory premixed with water for antifreeze solution. Viking requires Firefighter Eliminator F type 50% propylene <br /> glycol/water mixture,with a freeze temperature rating(freeze point)of-26 OF(-32.2°C). <br /> Refer to data page 45a-j"Viking ESFR Cold Storage System"in the Freezer Storage section of the Viking data book. <br /> IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Viking ESFR Pendent <br /> Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest standards <br /> of NFPA, VdS, LPCB, and any other Authorities Having Jurisdiction, and also with provisions of governmental <br /> codes, ordinances, and standards whenever applicable. <br />
The URL can be used to link to this page
Your browser does not support the video tag.