My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-54 2024-10-24
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-54
>
3003 W CASINO RD BLDG 40-54 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 11:30:27 AM
Creation date
7/24/2024 10:15:59 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-54
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 of 4 <br /> SPRINKLER GENERAL CARE, <br /> N I KJ:N:G* INSTALLATION, AND <br /> MAINTENANCE GUIDE <br /> The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com <br /> Visit the Viking website for the latest edition of this technical data page. <br /> B. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. <br /> C. Install the dry sprinkler on the piping using the special dry sprinkler wrench only, while taking care not to damage the sprinkler. <br /> NOTE: Thread the sprinkler into the fitting hand tight, plus 1/2 turn with the dry sprinkler wrench. <br /> D. For adjustable standard and adjustable recessed dry pendent and sidewall sprinklers: Escutcheons can be installed after the <br /> sprinklers have been installed onto the piping. Refer to the appropriate sprinkler technical data page for escutcheon installation <br /> instructions and illustrations. <br /> D. Installation Instructions-Testing <br /> 4.After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation stand- <br /> ards.Viking high pressure sprinklers may be hydrostatically tested at a maximum of 300 psi(20.7 bar)for limited periods of time <br /> (two hours), for the purpose of acceptance by the Authority Having Jurisdiction. <br /> a. Make sure the sprinkler is properly tightened. If a thread leak occurs, normally the sprinkler must be removed, new pipe-joint <br /> compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing <br /> compound or tape is washed out of the joint.Air testing [do not exceed 40 psi (2.76 bar)]the sprinkler piping prior to testing <br /> with water may be considered in areas where leakage during testing must be prevented. Refer to the Installation Standards <br /> and the Authority Having Jurisdiction. <br /> b. Remove plastic protective sprinkler caps or bulb shields AFTER the wall or ceiling finish work is completed where <br /> the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating ele- <br /> ments. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove <br /> caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. SPRINKLER CAPS OR BULB <br /> SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Retain a protective <br /> cap or shield in the spare sprinkler cabinet. <br /> 5. For flush style sprinklers: the ceiling ring can now be installed onto the sprinkler body. Align the ceiling ring with the sprinkler <br /> body and thread or push it on (depends on sprinkler model) until the outer flange touches the surface of the ceiling. Note the <br /> maximum adjustment is 1/4" (6.35 mm). DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple as required. <br /> 6. For concealed sprinklers: the cover assembly can now be attached. <br /> a. Remove the cover from the protective box, taking care not to damage the cover plate assembly. <br /> b. Gently place the base of the cover plate assembly over the sprinkler protruding through the opening in the ceiling. <br /> c. Push the cover plate assembly onto the sprinkler until the unfinished brass flange of the cover plate base (or the cover <br /> adapter, if used)touches the surface of the ceiling. <br /> d. Refer to the applicable technical data sheet to determin the maximum adjustment available for concealed sprinklers. DO NOT <br /> MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple. <br /> NOTE: If it is necessary to remove the entire sprinkler unit,the system must be taken out of service.See section 6. INSPECTIONS, <br /> TESTS AND MAINTENANCE and follow all warnings and instructions. <br /> 5. OPERATION <br /> Refer to the appropriate sprinkler technical data page(s). During fire conditions,the operating element fuses or shatters(depending <br /> on the type of sprinkler), releasing the pip cap and sealing assembly.Water flowing through the sprinkler orifice strikes the sprinkler <br /> deflector, forming a uniform spray pattern to extinguish or control the fire. <br /> IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Viking <br /> sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appro- <br /> priate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with <br /> the provisions of governmental codes, ordinances, and standards, whenever applicable. The sprinkler <br /> technical data page may contain installation requirements specific for the sprinkler model selected. <br /> The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having <br /> Jurisdiction prior to installation. <br /> Form No. F_080614 18.10.11 Rev 16.1.P65 <br />
The URL can be used to link to this page
Your browser does not support the video tag.