My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-54 2024-10-24
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-54
>
3003 W CASINO RD BLDG 40-54 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 11:30:27 AM
Creation date
7/24/2024 10:15:59 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-54
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OTTO ROSENAU & ASSOCIATES, INC. <br /> Geotechnical Engineering,Construction Inspection&Materials Testing <br /> PROPRIETARY ANCHOR MECHANICAL INSPECTION FIELD REPORT <br /> Job Number: 24-0253 Report Number: 463933 Permit Number: B2311-072 <br /> Project: Boeing Bldg 40-54 Rack Relocation Client: The Boeing Company <br /> Address: Bldg 40-54 Address: <br /> Inspector: M. Gray Date: Thursday,April 25, 2024 <br /> Description/Location: Anchors for rack supports, main floor, approx. grids E.3—F/6.3-7 for the interior and south of door S1 for <br /> exterior per layout on sheet 1521 & 1S22 of IFC drawings, dated 11/08/2023; details per 1/S700 <br /> Intended Use: Connection of base plates to structural slab Building Code&Year: IBC 2021 <br /> Anchor Type: ® Expansion ❑ Screw ❑ Sleeve ❑ Drop In Anchor Size&Quantity: (216)'/2" <br /> ESR Number: 4266 Anchor Manufacturer: HILTI KB-TZ2 <br /> Hole Diameter: '/2" Hole Depth: 2'/2" Required Embedment: 2'/2" <br /> Anchor Length: 4'/2" Concrete Thickness: NA Concrete Strength: NA <br /> Base Material: ® Normal Weight Concrete ❑ Light Weight Concrete ❑ CMU ❑ Brick ❑ Composite Deck <br /> Hole Cleaning: ❑ Compressed Air ❑ Hand Pump ❑ Other: NA <br /> Drill Bit(ANSI B212.15): ® Yes ❑ No ORA Torque Wrench ID: 6080 Torque: 50 ft-lbs <br /> Weather: Overcast Ambient Temperature: 52°F <br /> Comments <br /> All information verified except hole cleaning method/procedure. <br /> Reference Standard(s)Used: Conforms X Does Not Conform <br /> Start Time: Is this a re-inspection? ❑ Yes M No <br /> Finish Time: Original Inspection Date: <br /> Inspected by: �1 Reviewed by: <br /> This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau&Associates, Inc. Reproduction of this report, <br /> except in full,without written permission from our firm is strictly prohibited. <br /> Page of <br /> 6747 M.L.King Way S.,Seattle,Washington 98118-Phone(206)725-4600 or 1-888-OTTO-4-US-Fax(206)723-2221 <br /> Form No.:INSP-87-01 LT(Rev 7/09) <br />
The URL can be used to link to this page
Your browser does not support the video tag.