My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4717 BELVEDERE AVE 2025-03-25
>
Address Records
>
BELVEDERE AVE
>
4717
>
4717 BELVEDERE AVE 2025-03-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 10:38:10 AM
Creation date
7/24/2024 10:20:27 AM
Metadata
Fields
Template:
Address Document
Street Name
BELVEDERE AVE
Street Number
4717
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />No 11 ' SM SOLAR CODE COMPLIANCE NOTES C <br />NN MOUNT INSTALLATION GUIDI PA G E <br />SYSTEM LEVEL FIRE CLASSIFICATION <br />The system fire class rating requires installation in the manner specified in the SOLARMOUNT Installation Guide. SOLARMOUNT has been classified to the system <br />level fire portion of UL2703. SOLARMOUNT has achieved system level performance for steep sloped roofs. The fire classification rating is only valid on roof pitches <br />greater than 2:12 (slopes i 2 inches per foot, or 9.5 degrees). The system is to be mounted over fire resistant roof covering rated for the application. There is no <br />required minimum or maximum height limitation above the roof deck to maintain the system fire rating for SOLARMOUNT. Module Types, System Level Fire Ratings, <br />and Mitigation Requirements are listed below: <br />Rail Type <br />Standard & HD Rails <br />Module Fire Types <br />1, 2, 3 with Metal Frame, 10 with Metal <br />Frame,19, 22, 25, 29, & 30 <br />System Level Fire Rating I Rail Direction I Module <br />Orientation <br />Class A, Class B & Class C I East-West <br />North -South <br />Landscape OR Portrait <br />Landscape OR Portrait <br />Mitigation <br />Required <br />None Required <br />None Required <br />Light Rail <br />1 & 2 <br />Class A, Class B & Class C <br />East-West <br />Landscape OR Portrait <br />None Required <br />North -South <br />Landscape OR Portrait <br />None Required <br />Standard, Light, & <br />HD Rails <br />4 & 5 <br />Class A, Class B & Class C <br />East-West <br />Landscape OR Portrait <br />Trim installation per Solar <br />Mount Installation Guide <br />North -South <br />Landscape OR Portrait <br />This racking system may be used to ground and/or mount a PV module complying with UL1703 or UL61730 only when the specific module has been evaluated for <br />grounding and/or mounting in compliance with the included instructions. <br />UL2703 CERTIFICATION MARKING LABEL UNIRAC <br />Unirac SOLARMOUNT is listed to UL 2703. Certification marking is embossed on all mid clamps as shown. Labels with <br />additional information will be provided .After the racking system is fully assembled, a single label should be applied to the <br />SOLARMOUNT rail at the edge of the array. Before applying the label, the corners of the label that do not pertain to the col <br />system being installed must be removed so that only the installed system type is showing. C US <br />Note: The sticker label should be placed such that it is visible, but not outward facing. 266909 <br />SM STANDARD RAIL <br />NIRAC �> <br />�itlw,�[.Gpt/h►Ip1f ��•Ict�fTrrT <br />slw. n. t>.r. �. W �y� h.w..•u..r ti <br />TM�M /i� 11���4�M..Mr H MWq I�.rly/ M tYw �Mly M <br />Y.�r W/ dry M Y�IW�• lwwf� <br />Oar 1.•dl WNW AfpO► 11•Ynd••rJ� <br />� w.w.wwrw.ra <br />SM LIGHT RAIL <br />t�iwyr /r�•�.��•�.�wM 7• ht+.. yrAW n. [w� �Wq r� <br />Owl Iwo �•� W bM�r� IwY�1wr <br />aT \••� 4•a W1 •r Lp•�r Ild•►r 0•�.. <br />BLUE RAVEN <br />]u <br />1403 N.Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W.BLUERAVENS OLAR.COM <br />CONFIDENTIAL, THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NABCEP <br />CERTIFIED <br />P V INS TALLATION <br />PROFESSIONAL <br />Scott Gurney <br />#P V-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OP S <br />385-498-6700 <br />DRAWING BY: <br />PLOT DATE: <br />PROJECT NUMBER: <br />SHEET NAME: <br />SPEC SHEET <br />REVISION: PAGE NUMBER: <br />- - I SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.