Laserfiche WebLink
Edition 1 <br />Edition 19 <br />Edition 20 <br />PRODUCTS <br />S� CSA <br />GROUP' <br />September 20, 2017; Project 70131735 - Irvine <br />Prepared By: Michael Hoffnagle <br />Authorized By: Michael Hoffnagle <br />July 29, 2022; Project 80129816 - Irvine <br />Prepared By: Michael Hoffnagle <br />Authorized By: Michael Hoffnagle <br />August 12, 2022; Project 80136577 - Irvine <br />Prepared By: Michael Hoffnagle <br />Authorized By: Michael Hoffnagle <br />Report pages reissued <br />Descriptive Report MASTER CONTRACT: 266909 <br />p p REPORT: 70131735 <br />and Test Results PROJECT: 80136577 <br />MASTER CONTRACT: 266909 <br />REPORT: 70131735 <br />PROJECT: 80136577 <br />Contents: Certificate of Compliance - Pages 1 to 6 <br />Supplement to Certificate of Compliance - Pages 1 to 3 <br />Description and Tests - Pages 1 to 27 <br />Attl Installation Manual SM— Pages 1 to 38 <br />Att2 Schematics SM/ULA— Pages 1 to 72 <br />Att3 Installation Manual ULA— Pages 1 to 22 <br />Att4 RM5_Installation Guide - 1 to 19 <br />Att5 RMDT Installation Guide - 1 to 20 <br />Att6 RM series schematics — 1 to 32 <br />Att7 Installation Manual, GFT Shared Rail — Pages 1 to 41 <br />Att8 Installation Manual, GFT 4-Rail — Pages 1 to 40 <br />Att9 GFT Schematics — Pages 1 to 45 <br />Att10 NXT Horizon Installation Manual — Pages 1 to 23 <br />Att 11 Schematics NXT Horizon — Pages 1 to 27 <br />CLASS - C531302 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems <br />CLASS - C531382 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems - <br />Certified to US Standards <br />The reader is responsible for any liability arising from actions taken in interpreting or applying the results presented in this report. This report shall not be <br />reproduced except in full, without written approval from CSA Group Testing & Certification Inc. The results of this report only relate to those items tested. <br />34 Bunsen, hvine, C�, U S.A 92618 <br />Telephone: 949.733.43001.800.463.6727 Fax 949.733.4320 www.csagroup.org <br />DQD 507.10 Rev 2022-08-05 <br />© 2022 CSA Group. All rights reserved. <br />Page No: 2 <br />Date Issued: August 12, 2022 <br />Models: <br />SM <br />- <br />SOLARMOUNT Flush -to -Roof is an extruded aluminum rail PV <br />racking system that is installed parallel to the roof in landscape or <br />portrait orientations. <br />ULA <br />- <br />Unirac Large Array is a ground mount system using the SolarMount <br />(SM) platform for the bonding and grounding of PV modules. <br />Solarmount <br />The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. <br />The system is secured to the roof with the L-Foot components through the roofing material to building structure. <br />Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end <br />clamps. The modules are bonded to the racking system with the stainless -steel bonding mid clamps with piercing <br />points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A <br />with Type 1, 2, 3 (with metallic frame), 4 (with trim), 5 (with trim), 10(with metallic frame), 19, 22, 25, 29, or 30 for <br />steep slope. Tested at 5" interstitial gap which allows installation at any stand-off height. <br />The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to <br />include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All <br />groundingibonding connections are to be torqued in accordance with the Installation Manual and the settings used <br />during the certification testing for the current edition of the project report. <br />The system may employ optimizers/micro-inverters and used for grounding when installed per installation <br />instructions. <br />UL 2703 Mechanical Load ratings: <br />Test Loads: <br />DQD 507.10 Rev 2022-08-05 <br />Module Area up to 22.2 sq ft <br />Downward Design Load (lb/ft2) <br />113.5 <br />Upward Design Load (lb/ftZ) <br />50.7 <br />Down -Slope Load (lb/ft2) <br />16.13 <br />Module Area up to 27.12 sq ft <br />Downward Design Load (lb/ft2) <br />33.9 <br />Upward Design Load (lb/ft2) <br />33.9 <br />Down -Slope Load (lb/ft2) <br />16.5 <br />Module Area up to 22.2 sq ft <br />Downward Load (lb/ft2) <br />170.20 <br />Upward Load (lb/ft2) <br />76.07 <br />Down -Slope Load (lb/ftZ) <br />24.2 <br />Module Area up to 27.12 sq ft <br />Downward Design Load (lb/ftZ) <br />50.85 <br />Upward Design Load (lb/ftZ) <br />50.85 <br />Down -Slope Load (lb/ftZ) <br />24.75 <br />© 2022 CSA Group. All rights reserved. <br />BLUE RAVEN <br />]u <br />1403 N. Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W.BLUERAVENS OLAR.COM <br />CONFIDENTIAL, THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NA CEP <br />CERTIFIED <br />PV INS TALLATION <br />PROFESSIONAL <br />Scott Gurney <br />#P V-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OP S <br />385-498-6700 <br />DRAWING BY: <br />PLOT DATE: <br />PROJECT NUMBER: <br />SHEET NAME: <br />SPEC SHEET <br />REVISION: PAGE NUMBER: <br />- - I SS <br />