4717 BELVEDERE AVE 2025-03-25
>
Address Records
>
BELVEDERE AVE
>
4717
>
4717 BELVEDERE AVE 2025-03-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 10:38:10 AM
Creation date
7/24/2024 10:20:27 AM
Metadata
Fields
Template:
Address Document
Street Name
BELVEDERE AVE
Street Number
4717
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RESIDENTIAL PHOTOVOLTAIC PERMIT APPLICATION (Page 1 of 2) <br />CITY OF EVERETT PERMIT SERVICES <br />EVERETT SUBMITTAL INSTRUCTIONS: Email application to PermitServices@everettwa.gov or drop off at 3200 Cedar Street 2nd Floor Drop Box <br />CONTACT INFORMATION: (P) 425-257-8810 1 (E) PermitServices@everettwa.gov I (W) everettwa.gov/permits <br />WASHINGTON <br />PROJECT SITE INFORMATION <br />PROJECT ADDRESS: 4717 Belvedere Ave, Everett, Washington, 98203 PARCEL #: 00417100003500 <br />BUILDING TYPE: ❑ SFR-DETACHED ❑ SFR-ATTACHED / TOWNHOUSE ❑ DUPLEX <br />CONTACT INFORMATION <br />OWNER NAME: Moses Sinclaire <br />CONTRACTOR NAME: BRS Field Ops, LLC <br />CONTRACTOR LIC. #(REQUIRED): BRSFIF0820N3 <br />CITY OF EVERETT BUSINESS LIC. #(REQUIRED): 60040 <br />PRIMARY CONTACT: ❑ OWNER ®CONTRACTOR El OTHER (Please Specify) <br />CONTACT NAME: <br />Lacy Holliday <br />CONTACT PHONE: 385-482-0045 <br />CONTACT EMAIL: permitting.department@blueravensolar.com <br />SOLAR PANEL APPLICATION INFORMATION <br />PV SYSTEM DESCRIPTION (include manufacturer and model, # of PV modules and inverters): <br />DC SYSTEM SIZE: 10.5 kW DC <br />MODULE TYPE: (25) REC Solar REC420AA PURE-R <br />INVERTER TYPE: Enphase IQ7X-96-2-US <br />BUILDING PERMIT CHECKLIST <br />DETERMINE IF YOUR PROJECT QUALIFIES FOR AN OVER-THE-COUNTER BUILDING PERMIT: <br />If you answer yes to all of the below questions, the project qualifies for an over-the-counter building permit. <br />YES <br />NO <br />1. PV system is designed and proposed for a detached one- or two-family dwelling or townhouse not more than three <br />stories above grade or detached accessory structure that is code compliant to setbacks and height, or code allows <br />expansion of nonconformity for solar modules. [IRC 101.2] <br />❑ <br />2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by the local jurisdition. <br />Q <br />❑ <br />3. Rooftop is made from lightweight material such as a single layer of composition shingles, metal roofing, lightweight <br />masonry, or cedar shingles. <br />❑ <br />❑ <br />4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2] <br />0 <br />❑ <br />5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all required electrical permit(s) must <br />be obtained from the Authority having Jurisdiction to administer the electrical code. [IRC M2302.2] <br />D <br />❑ <br />6. The installation shall meet the requiremetns of the International Fire Code as amended by WA State. [IRC M2302.2] <br />D <br />❑ <br />7. The PV system is designed for the wind speed of the local area, and will be installed per the manufacturer's <br />specifications. [IRC M2302.2.1(1)] <br />0 <br />❑ <br />8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(1)] <br />ID <br />❑ <br />9. The total dead load of modules, supports, mountings, raceways, and all other appurtenances weigh no more than four <br />per square foot. [IRC M2302.2.1(3)]. Enter total dead load of system (lbs/sq.ft.): <br />El <br />10. To address uplift, modules are mounted no higher than 18" above the surface of the roofing to which they are affixed. <br />[IRC M2302.2.1(4)] <br />D <br />❑ <br />11. Supports for solar modules are installed to spread the dead load across as many roof -framing members as needed to <br />ensure that no point load exceeds fifty (50) pounds. [IRC M2302.2.1(5)] <br />❑ <br />❑ <br />12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire -retardant <br />treated wood equivalent to that required for the roof construction. [IRC M2302.2.1] <br />❑ <br />13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, rodents, and insects. [IRC M2302.2.2] <br />❑�/ <br />❑ <br />14. PV modules are listed and laveled with a fire classification in accordance with UL 1703. [IRC M2302.2.3] <br />El <br />❑ <br />Comments: <br />PLEASE FILL OUT A CITY OF EVERETT BUILDING PERMIT APPLICATION IF YOU QUALIFY FOR AN OTC BUILDING PERMIT. <br />Continue on to Page 2 of Application <br />City of Everett Official Use Only <br />ASSOCIATED BUILDING PERMIT # <br />B <br />(Revised 412112022) <br />