Laserfiche WebLink
STRUCTURAL INFORMATION: <br />STRUCTURAL NOTES: <br />UNIRAC UNIVERSAL <br />AF END CLAMP A <br />UNIRAC UNIVERSAL PV MODULE <br />AF MID CLAMP ;11" <br />ROOF TYPE (1): <br />ROOF TYPE: Concrete W-Tile1 <br />rL <br />SHEATHING TYPE: OSB <br />BLUE R AV E IV <br />FRAMING TYPE: Manufactured Truss <br />None <br />FRAMING SIZE: 2x4 @ 24" OC <br />CEILING JOIST SIZE: 2x4 @ 24" OC <br />/ <br />1403 N. Research Way <br />16" MAX. �48" MAX. — <br />LANDSCAPE <br />Orem, UT 84097 <br />ATTACHMENT: SOLARHOOK UNIVERSAL <br />800.377.4480 <br />RACKING: Unirac Solarmount LT <br />WWW.BLUERAVENSOLAR.COM <br />CONFIDENTIAL -THE INFORMATION <br />@ 24" OC Portrait / 48" OC Landscape <br />UNIRAC UNIVERSAL UNIRAC UNIVERSAL PV MODULE <br />NUMBER OF ATTACHMENTS: 100 <br />AF END CLAMP AF MID CLAMP <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />PV MODULE COUNT: 25 Modules <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />TOTAL ARRAY AREA: 510.0 ft2 (20.4ft2/panel) <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />TOTAL ROOF AREA: 2282 ft2 <br />0 0 <br />0 <br />0 o <br />IN CONNECTION WITH THE SALE AND <br />ARRAY/ROOF AREA: 22.3% <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />ARRAY WEIGHT: 1,250 Ibs (50 Ibs/panel) <br />OF BLUE RAVEN SOLAR LLC. <br />DISTRIBUTED LOAD: 2.45 Ibs/ft2 <br />8" MAX. 24" MAX. <br />PORTRAIT <br />POINT LOAD: 12.5 lbs/attachment <br />`NOTE: LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY <br />ATTACHMENT SPACING -FRONT VIEW _RACKING ATTACHMENTS TO BE STAGGERED <br />C <br />NABCEP <br />BASED ON FIELD CONDITIONS. MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER <br />ENGINEER OF RECORD SPECIFICATIONS. <br />SCALE: 3/4" = 1'-0" <br />"CONCRETE TILES NOT SHOWN FOR CLARITY <br />CERTIFIED <br />UNIRAC SOLARHOOK UNIVERSAL <br />PV INSTALLATION <br />PV MODULE <br />PROFESSIONAL <br />Scott Gurney <br />#PV-011719-015866 <br />PORTRAIT <br />CONTRACTOR: <br />BRS FIELD OPS <br />10" MIN. <br />ROOF STRUCTURE <br />800-377-4480 <br />REC SOLAR REC420AA PURE-R <br />16" MAX. <br />UNIRAC UNIVERSAL AF MID/END CLAMP <br />PV MODULE <br />2'-10" MIN. <br />10" MIN. 3'-10" MAX. <br />U <br />16" MAX. <br />, , Q U <br />LANDSCAPE <br />z � <br />UNIRAC SM RAIL LT <br />O Y <br />23' <br />M <br />Q N I <br />(E) CONCRETE <br />1'-8" MIN. <br />00 o <br />UNIRAC SOLARHOOK <br />W-TILE ROOF <br />N ~ <br />O <br />UNIVERSAL <br />Q O � N N <br />ATTACHMENT SPACING- SIDE VIEW <br />z a> a) � y N <br />v <br />SCALE: 1/2" = 1'-0" <br />) <br />-- ____ <br />Cn <br />W > >� H H <br />(n > <br />--- __- <br />N co N <br />m >. <br />°' <br />"'I <br />A C,g 1 <br />L6` <br />vOi a co in <br />m <br />i <br />Sealed For <br />Existing Roof & <br />O �,oF w'��riy <br />~ �' ��A <br />v 2 w Q <br />DRAWING BY: <br />2Y2' MIN. EMBED <br />Attachment Only <br />(E) ROOF SHEATHING <br />Brendan Fillmore <br />(2) 5/6'x3-1/2" STAINLESS STEEL <br />PLOT DATE: <br />LAG BOLTS W/ EPDM <br />46056 <br />BONDED WASHER <br />C.so���4 <br />November 3, 2023 <br />PROJECT NUMBER: <br />(E) BUILDING STRUCTURE <br />11/3/23 <br />870808 <br />SHEET NAME: <br />STRUCTURAL <br />-LAG BOLTS MUST BE LOCATED IN THE MIDDLE <br />TYP. ATTACHMENT DETAIL <br />THIRD OF THE STRUCTURAL MEMBER <br />REVISION: <br />PAGE NUMBER: <br />SCALE: 3" = V-0" <br />-INSTALL AND TOURQUE TO MANUFACTURER <br />0 <br />PV4 <br />SPECIFICATIONS <br />