STANDARD LABELS ADDITIONAL LABELS <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> WARNINGFOR PV SYSTEM DISCONNECTING MEANS WHERE THE WARN I N G PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. MAIN DISTRIBUTION UTILITY DISCONNECT(S) DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> 12017 NEC 690.13(8)] POWER TO THIS BUILDING IS ALSO SUPPLIED SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 <br /> TERMINALS ON THE LINE AND 12020 NEC 690.13(8)] FROM A ROOF MOUNTED SOLAR ARRAY WITH LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> LOAD SIDES MAY BE ENERGIZED A RAPID SHUTDOWN DISCONNECTING MEANS DISCONNECT(S)FOR ALL ELECTRIC POWER 800.377.4480 <br /> IN THE OPEN POSITION GROUPED AND LABELED WITHIN LINE OF SITE PRODUCTION SOURCES CAPABLE OF BEING WWW.BLUERAVENSOLAR.COM <br /> AND 10 FT OF THIS LOCATION INTERCONNECTED. <br /> CONFIDENTIAL-THE INFORMATION <br /> (2017 NEC 705.10] HEREIN CONTAINED SHALL NOT BE <br /> (2020 NEC 705.10] USED FOR THE BENEFIT OF ANYONE <br /> LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> I AC DISCONNECT I AND WITH THE RATED AC OUTPUT CURRENT AND THE I WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> RATED AC OUTPUT CURRENT 24.89 A 12017 NEC 690.541 POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES USE OF THE RESPECTIVE EQUIPMENT, <br /> 12020 NEC 690.541 WITHOUT THE WRITTEN PERMISSION <br /> SUPPLIED FROM MAIN DISTRIBUTION SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> NOMINAL OPERATING AC VOLTAGE 240 V LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> PRODUCTION SOURCES CAPABLE OF BEING <br /> INTERCONNECTED. NABC E P <br /> LABEL 3 [2017 NEC 705.10] <br /> IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL [2020 NEC 705.10] CERTIFIED] <br /> ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br /> DUAL PMUTILITYGRIDAN7D <br /> AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL <br /> AND SUBPANELS. LABEL 10 PV INSTALLATION <br /> 12017 NEC 705.12(8)(3)] I WARN I N G PERMANENT PLAQUE OR DIRECTORY TO BE PROFESSIONAL <br /> SOURCES: (2020 NEC 705.12(8)(3)) LOCATED AT MAIN SERVICE EQUIPMENT DENOTING Scott Gumey <br /> PV SOLAR ELECTRIC SYSTEM <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: <br /> ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN <br /> OWARI LABEL4 BRS FIELD OPS <br /> I APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METER. SERVICE DISCONNECTING MEANS. <br /> TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] 800-377-4480 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. (202oNEC 705.10AND 690.56(C)] <br /> (2017 NEC 705.12(B)(2)(3)(b)] <br /> DO NOT RELOCATE (2020 NEC 705.12(8)(3)(2)] <br /> THIS OVERCURRENT LABEL 11 0 <br /> DEVICE ! WARN I N PERMANENT PLAQUE OR DIRECTORY TO BE Q V <br /> IL LOCATED AT AC COMBINER PANEL. <br /> P [2017 NEC 110.21(8)] <br /> PHOTOVOLTAIC SYSTEM Z <br /> WA N G LABEL 5 [2020 NEC 110.21(8)] Q <br /> APPLY TO THE PV COMBINER BOX COMBINER PANEL C) 00 00 <br /> Q CV 00 °p <br /> (2017 NEC 705.12()(2)(3)(c)J C <br /> 12020 NEC 705.12(8B)(3)(3)] DO NOT ADD LOADS 00c <br /> THIS EQUIPMENT FED BY MULTIPLE a/ . ~ <br /> SOURCES.TOTAL RATING OF ALL 0 W W <br /> OVERCURRENT DEVICES,EXCLUDING PV 0 N N <br /> MAIN SUPPLY OVERCURRENT SUBPANEL Z > N CO <br /> DEVICE,SHALL NOT EXCEED UTILITY MAIN (IF INTERCONNECTION AC METER PV COMBINER <br /> AMPACITY OF BUSBAR. METER SERVICE PANEL IS MADE HERE) DISCONNECT (IF APPLICABLE) BOX W O U) W W <br /> � � x � <br /> LABEL 6 0 0 0 0 0 0 0 0 0 Z 0 >->. <br /> SOLAR PV SYSTEM EQUIPPED BUILDINGS WITH PV SYSTEMS SHALL HAVE A I.— 01) L y y <br /> Cq <br /> WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE O O O O O O O CU C) > V (� <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS 0 J (D Lij Q Q <br /> TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY <br /> SWITCH TO THE VISIBLE LOCATION AND SHALL INDICATE THE LOCATION IF BREAKER <br /> "OFF"POSITION TO sop a salt 4 IS USED 4 9 9 OR PLACARD 11 DRAWING BY: <br /> SHUT DOWN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. <br /> AND REDUCE (2017 NEC 690.56(C)(1)(a)] <br /> SHOCK HAZARD <br /> IN THE ARRAY 12020 NEC 690.56(C)] O$ OR 10 Emily North <br /> OR PLACARD PLOT DATE: <br /> LABEL 7 <br /> RAPID SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT August 2, 2023 <br /> 111116 SWITCH FOR SWITCH <br /> wr 12017 NEC 690.56(C)(3)] PROJECT NUMBER: <br /> SOLAR PV SYSTEM (2020 NEC 690.56(C)(2)] <br /> 820030 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE A PV7 <br /> HANDWRITTEN[NEC 110.211 DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />