SCOPE OF WORK GOVERNING CODES SYSTEM RATING PHOTOVOLTAIC SYSTEM FIRE <br /> TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE CLASSIFICATION LISTING IN 400 kWDC 4. <br /> io7 <br /> . <br /> LOCATED AT 10121 25TH AVE SE, EVERETT, WA 98208, USA. 2018 INTERNATIONAL FIRE CODE ACCORDANCE WITH UL 1703 <br /> THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY 2018 INTERNATIONAL BUILDING CODE 3.300 kWAC STANDARD <br /> Lum — <br /> GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 2018 INTERNATIONAL RESIDENTIAL CODE LUMIO <br /> 2020 NATIONAL ELECTRICAL CODE SHEET INDEX 1550 DIGITAL DR,LEHI,UT <br /> THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. WASHINGTON ADMINISTRATIVE CODE (WAC) 84043,USA <br /> PV1 COVER PAGE <br /> EQUIPMENT SUMMARY I AHJ NAME : CITY OF EVERETT PV2 SITE PLAN <br /> 11 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES WIRING AND CONDUIT NOTES PV3 ROOF PLAN <br /> 11 ENPHASE IQ8PLUS-72-2-US (240V) MICROINVERTERS • ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND PV4 STRING LAYOUT&BOM <br /> APPROVAL FOR THE SITE APPLICATIONS <br /> GENERAL NOTES - ALL <br /> ATTACHMENT DETAILS <br /> CABLING <br /> • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND ALL PV CABLES AND WIRES BE#1 ,USE 2, PV WIRE, OR PV7 ELECTRICAL LINE&CALCS. <br /> OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE PROPRIETARY SOLAR CABLING SPECIFIED BYYAWG MFR, OR EQUIVALENT; ROUTED TO SYSTEM INFO <br /> MODIFICATIONS IN CONSTRUCTION DETAILS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED PV8 SPECIFICATIONS&NOTES <br /> (11)Q CELLS <br /> ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE PV9-PV10 SIGNAGE Q.PEAK DUO BILK ML-G10+ <br /> • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL DERATED ACCORDING TO AS PER LATEST NEC CODE. (40OW) <br /> PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. PV11 JOB SAFETY PLAN <br /> EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90'C RATED, WET AND UV (11)ENPHASE <br /> • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS PV12-PV19 EQUIPMENT SPECIFICATIONS Q8STE -SIZE: S(0 kW <br /> AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE DC SYSTEM SIZE:4.400 kW <br /> USED TO PROTECT WIRE FROM SHARP EDGES <br /> BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND PROJECT SITE AC SYSTEM SIZE:3.300 kWAC <br /> ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 <br /> CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL INSULATED, 90'C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER <br /> COMPENSATION. APPLICABLE NEC <br /> • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER <br /> ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE REVISIONS <br /> CONTRACTOR AT NO ADDITIONAL COST. MEANS DESCRIPTION DATE REV <br /> • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION ', -I►` R <br /> COMPLETION OF THE WORK WITH APPROVED MATERIALS. - VOLTAGE DROP LIMITED TO 2% 17 <br /> '. <br /> • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING . AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, <br /> PERMIT IS PROPERLY DISPLAYED. PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL-WHITE/GRAY <br /> • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE _ PROJECT NAME&ADDRESS <br /> WITH THE REQUIREMENTS OF THE NATIONAL BUILDING CODE, THE DEPARTMENT OF <br /> ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. Q <br /> • IT 1 S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL �� U) <br /> PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. D <br /> THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. : -- C <br /> • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE 'p N <br /> LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. 00 <br /> m <br /> • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, t Q CD <br /> ETC.AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. Z N � <br /> • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. 0 o <br /> Y W C) ~ o <br /> HOUSE PHOTO SCALE:NTS (� U CD W O <br /> ELECTRICAL NOTES Z o <br /> • ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. PROJECT SITE Q > CN <br /> • ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET Fobe J c00 <br /> 00 <br /> ENVIRONMENT. WW U uj <br /> 1, LLI N <br /> • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY U) O Lu <br /> it <br /> TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. Z <br /> • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALLD_ Q d <br /> COMPLY WITH NEC 110.26. 526 - = Q <br /> • WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CASCADE VI Lo <br /> CONTRACTOR SHALL SIZE THEM ACCORDINGLY. N <br /> • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. N <br /> • MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE o <br /> SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. Paine EaStmont <br /> • MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE Field-Lake © o„ DATE:7/1/2023 <br /> Stickney 96 — <br /> SHEET NAME <br /> rth SILVER FIRS COVER PAGE <br /> rt Mill Creek <br /> Go"1g1e ake SHEET SIZE <br /> LfEE <br /> ANSI B <br /> VICINITY MAP SCALE:NTS 11" X 17" <br /> SHEET NUMBER <br /> PV-1 <br />