1 5 • <br /> DISCONNECTTILITY LUM10 <br /> LUMIO <br /> ELECTRIC SHOCK HAZARD LABEL LOCATION: 1550 DIGITAL DR,LEHI,UT <br /> AC DISCONNECT 84043,USA <br /> TERMINALS ON BOTH LINE AND LOAD SIDES MAY PER CODE: NEC 690.56(C)(2) <br /> BE ENERGIZED IN THE OPEN POSITION <br /> LABEL LOCATION: <br /> POINT OF INTERCONNECTION,MAIN SERVICE 6PHOTOVOLTAIC AC DISCONNECT <br /> DISCONNECT,AC DISCONNECT,AC COMBINER, <br /> INVERTER RATED AC OUTPUT CURRENT 13.31 AMPS <br /> PER CODE:NEC 690.13(B) NOMINAL OPERATING , VOLTS <br /> SYSTEM INFO <br /> LABEL LOCATION: (11)Q CELLS <br /> ACAUTION INTERACTIVE SYSTEM POINT OF INTERCONNECTION Q PEAK DUO BILK ML-G10+ <br /> (400W) <br /> PER CODE:NFPA 70,NEC 690.54 <br /> (11)ENPHASE <br /> IQ8PLUS-72-2-US(240V) <br /> DUAL • - • DC SYSTEM SIZE:4.400 kWDC <br /> SECOND SOURCE 7 WARNING AC SYSTEM SIZE:3.300 kWAC <br /> PHOTOVOLTAIC INVERTER OUTPUT CONNECTION <br /> DO NOT RELOCATE THIS <br /> OVERCURRENT DEVICE <br /> REVISIONS <br /> LABEL LOCATION: LABEL LOCATION: DESCRIPTION DATE REV <br /> MAIN SERVICE DISCONNECT/AC DISCONNECT/ PLACE THIS LABEL AT P.O.C.TO SERVICE <br /> MAIN SERV CE PANEL/ REVENUE METER/AC DISTRIBUTION EQUIPMENT(I.E.MAIN PANEL <br /> COMBINER (AND SUBPANEL IF APPLICABLE)) <br /> PER CODE:NEC 705.12(C) PER CODE:NEC 705.12(B)(3)(2) <br /> 3 <br /> CAUTION : SOLAR ELECTRIC Q WARNING: PROJECT NAME&ADDRESS <br /> SYSTEM CONNECTED v <br /> PHOTOVOLTAIC POWER SOURCE < <br /> LABEL LOCATION: U) <br /> POINT OF INTERCONNECTION&INVERTER LABEL LOCATION: Z) <br /> PER CODE:NEC 690.15&690.13(B) CONDUIT <br /> OCT <br /> PER CODE:NEC 690.31(D)(2) N <br /> W <br /> m <br /> 4 SOLAR PV SYSTEM EQUIPPED Q g <br /> WITH RAPID SHUTDOWN 9 CAUTION : SOLAR CIRCUIT Q 00 co <br /> Z N `0 <br /> 00 o <br /> Y w N <br /> TURN RAPID LABEL LOCATION: U U O w O <br /> SHUTDOWN SWITCHMARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT,RACEWAYS, } Z W O <br /> TO THE OFF' ENCLOSURES,AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND w <br /> POSITION TO SHUT <br /> DOWN PV SYSTEM SOPAPANELS iC ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES J w � <br /> AND REDUCE PER CODE:IFC 606.11.1.4 w w U LLI N <br /> SHOCK HAZARD IN u) w L <br /> THE ARRAY U) O w <br /> 10WARNING - Electric Shock Hazard <br /> IL <br /> LABEL LOCATION: ' user serviceable parts = Q <br /> MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE • • • provider ' ~ <br /> Ln <br /> PLACE IT THERE/IF MSD IS INSIDE PLACE ON THE N <br /> AC DISCONNECT LABEL LOCATION: <br /> PER CODE:2020 NEC 690.56(C) INVERTER&JUNCTION BOXES(ROOF) <br /> N <br /> PER CODE:NEC 690.13(G)(3)&690.13(G)(4) O <br /> r <br /> DATE:7/1/2023 <br /> SHEET NAME <br /> SIGNAGE <br /> ADHESIVE FASTENED SIGNS SHEET SIZE <br /> • THE LABEL SHALL BE SUITABLE FOR THE <br /> ENVIRONMENT WHERE IT IS INSTALLED. ANSI B <br /> • WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL 11" X 17" <br /> FIELD APPLIED LABELS,WARNING AND MARKINGS <br /> SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) <br /> NOT ALL LABELS SHOWN ARE REQUIRED. FINAL FIELD MARKING]. SHEET NUMBER <br /> LABELLING TO BE DETERMINED BY THE SCOPE OF • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PV-9 <br /> WORK PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER <br /> RESISTANT[IFC 605.11.1.31 <br />