My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1049 CROWN DR 2023 Plans 2024-07-30
>
Address Records
>
CROWN DR
>
1049
>
Plans
>
1049 CROWN DR 2023 Plans 2024-07-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2024 2:07:19 PM
Creation date
7/30/2024 2:07:10 PM
Metadata
Fields
Template:
Address Document
Street Name
CROWN DR
Street Number
1049
Permit
B2309-063
Year
2023
Notes
INSTALLATION OF 12 PILES TO STABILIZE HOME
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> • <br /> PILE SPACING&LOAD REQUIREMENTS TABLE <br /> SITE PLAN LEGEND <br /> MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips <br /> PILE q PILE TYPE 200%MIN VERTICAL CAPACITY LOCATION e <br /> BTWN PILES END OFFSET ALLOWABLE LOADING MIN ULTIMATE CAPACITY • - 4 <br /> ri <br /> EXISTING RESIDENCE STRUCTURE ' ( ) • <br /> 1-2,8-10 HELICAL 11.0k/PILE 22.0 k/PILE EXTERIOR •-;•D.w. <br /> EXISTING ADJACENT STRUCTURE 7-D <br /> __ ;\� 3-7 HELICAL PER PLAN 7.0 k/PILE 14.0 k/PILE EXTERIOR <br /> AREA OF PROPOSED WORK / •• 2-8 CONCENTRIC PER PLAN 18.0 k/PILE 36.0 k/PILE CHIMNEY <br /> ___, �� NOTES: <br /> * PROPERTY LINE / \ 4APS — a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE <br /> MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> �� I CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> APPROXIMATE DIMENSION '�• EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM <br /> / ` INSTALLATION TORQUE RATING OF 8,300FT'LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL <br /> HELICAL PILE / THICKNESS PER ESR-3750. <br /> �\ b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" <br /> �\ TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. <br /> + CONCENTRIC PILE / •\ c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. <br /> d. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART <br /> �\ OF THE ASSEMBLY. Q , 6 <br /> / �• • e. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. _ <br /> // '•'� FOUNDATION NOTES F- W ;` <br /> '\ 01. VERIFY ALL DIMENSIONS ON SITE. <br /> / •• <br /> • 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. W1. <br /> / \ 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: Z z <br /> / '\` HELICAL PILE_._.....1/SD-1.1 0 Q <br /> / N. DRIVEN PILE............2/SD-1.1 —I4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED SEPTEMBER 17TH,2023,FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND <br /> '\ REQUIREMENTS. <br /> ' 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED JULY 17TH,2023.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND <br /> \\111, <br /> 7- ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. <br /> / \'dF 6. MINIMUM PILE DIAMETER SHALL BE 2-7I8'.`�• 7,�qxI-1i7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH t 0'8'TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED )1s <br /> - �c DURINGPILE INSTALLATION PROVIDEDTHATNOTWO ADJACENT SPANSEXCEEDTHESPACING LIMITATION ASINDICATEDONLEVEL SURVEY.' z �-2-Q 6 '� 8. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8'THICK MINIMUM WITH 2'4i'HEIGHT(MEASURED FROM <br /> m . '\ B/PTG TO TICONC)MINIMUM. <br /> •\ 9. PARCEL AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,')APPROXIMATED PER SNOHIMISH COUNTY iMAP.NOT TO BE USED FOR LEGAL <br /> 2� • <br /> �O 8 N PURPOSES. <br /> ��• ^ �� 10.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. <br /> Q,Q.5> 1 �� Ti.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"(UNO PER GEOTECHNICAL REPORT). <br /> Ir. <br /> ¢� \ HELICAL PILE REFUSAL CRITERIA: <br /> 9 TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH <br /> rie----6,..6„ J `�� A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. <br /> / '� <br /> / �NN DRIVEN PILE REFUSAL CRITERIA. <br /> i .` ADVANCEMENT OF THE PILE SHALL CONTINUE BEYOND THE MINIMUM EMBEDMENT DEPTH AND UNTIL A WORKING PRESSURE IS ACHIEVED TO PROVIDE <br /> o 10 '\ THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE <br /> h - �\ STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. <br /> '� <br /> % '\ 1049 CROWN DR <br /> / •• EVERETT <br /> o .` ti <br /> WA 98203 <br /> / W '` LOCATE PILE , Access <br /> 'RESIDENCE 17 '� WITHIN 3'-0` �'t.�,) �6^I • <br /> LOCATE PILE <br /> 1049 CROWN DR � N S•IT <br /> N FROM CORNER �"- • ppDpM COflNER <br /> EVERETT,WA 98203 �' �•' -., - - = S230726-1XR <br /> \` (5)PILES @ T-0'OC MAX <br /> 1- - JT <br /> i .`'l r-0'oc <br /> MAX <br /> — — 4. {3)PILES a <br /> ?'"- <br /> • T-0'OC MAX M RT <br /> - I `— _ .-. .. ® =ExistingPost <br /> / -6 2'LOCATE PILE UNDER <br /> 6.5' CHIMNEY FIG AT <br /> 09/17/2023 <br /> PARCEL NO. a-?+� CHIMNEYSTRIP PIG <br /> CORNER < =3"Helical Pile <br /> 00464700002500 I ' "' s e —v Im <br /> -FI- "1 =Concentric Pier <br /> / LEGAL DESCRIPTION 6.5 -4 1/2 - ffi=4x4 Postwith�dj. <br /> I HARBOR VIEW ADD TO EVERETT I ) -- - $ compos a pa <br /> BLK 000 D-00-LOT 25 _ <br /> I OWNER NAME&ADDRESS 38'6„ <br /> L <br /> 8I DESMARAIS JANEAN/CLEVER BRAD !1049 CROWN DR <br /> EVERETT,WA 98203 IZa �-' °� -3 5/8 -1 1- GasN <br /> a e vIw I•aI <br /> �•- - 10 <br /> U I . -2 5/8 00 <br /> �•�•_-_- - C I 38.5' <br /> Sao_-o• I R&R LEVEL SURVEY <br /> PROPERTY LINE — I See Structural Calculation Package for Additional Requirements <br /> -- _ I z <br /> _ ........................ <br /> _ _ _ N <br /> CL LA <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN ~ <br /> u) <br />
The URL can be used to link to this page
Your browser does not support the video tag.