Laserfiche WebLink
Information for system operator/owner <br /> Contact your system manufacturer/distributor to ensure factory trained and <br /> certified personnel perform repairs,maintenance,or servicing of the suppression <br /> LA TORTUGA INSTALLED BY system.Failure to do so may compromise the UL listing of the hood suppression <br /> 9601 EVERGREEN WAY ALL—AMERICAN FIRE PROTECTION INC. system,void the warranty and jeopardize insurance claims resulting from a fire. <br /> EVERETT, WA 98204 P.O. BOX 393 EVERETT,WA 98206 <br /> PHONE: 360—474-9773 FAX: 360—631 -5146 RANGE GUARD 6 AUTOMATICL <br /> GALLON FIRE GAS SHUTOFF <br /> ICC CERT#9917130 SYSTEM <br /> Link temperatures test will to be performed at time of trip test. <br /> (2)X ADP DUCT (2)X ADP <br /> NOZZLES „ r NOZZLES DU� <br /> 8 FT 6 IN HOOD 12 X 24' 12"X 24" <br /> 8 FT 6 IN HOOD <br /> ADP ADP <br /> NOZZLE NOZZLE <br /> FIRE SYSTEM TIED <br /> ���� INTON MAIN <br /> 4-10. ADP A pace BUILDING ALARM <br /> Appliance NOZZLE ADPF 6'inside SYSTEM <br /> 6"inside 13"-48" NOZZLE ADP NOZZLE h od <br /> hood 13"-48" NOZZLE 27"-45" <br /> 13"-48" <br /> p. Connection <br /> O <br /> ER UPR to electrical <br /> NOZZLE NOZZLE shutdown <br /> 16"-17" 16"-17" upon <br /> REMOTE PULL STATION <br /> � 1activation <br /> N 1 J fl�•1 I l l <br /> SHALL BE INSTALLED 42"-48"AVOVE THE •t •� -� 1� e <br /> FLOOR AT A DISTANCE>10 FT FROM THE D /� V <br /> 42 —48HAZARD BUT NOT MORE THAN 20 FT.IT Y C <br /> fell SHALL BE INSTALLED IN THE PATH OF <br /> EGRESS AND REQUIRE A MAXIMUM <br /> FORCE OF 40 LBS.AND A MAXIMUM <br /> MOVEMENT OF 14"FOR ACTUATION <br /> IF U <br /> 1 1 1 1 <br /> 00111ETQBxi1lBIM GAS GRIDDLE GAS GRIDDLE GAS 6-BURNER GAS RANGE <br /> swaBExS740C-+rMM 60"X 24" 36"X 24" FRYER 36"X 24" <br /> N FII FLOOR <br /> 15"X 23" Permit#: K2403-002 <br /> Site Address: 9601 Evergreen Way <br /> Applicant: All American Fire <br /> Application Date: 03/11/2024 <br /> Description: Kitchen Hood and Duck <br /> PIPING SIZE UL 300 COMPLIANT SYSTEM Wet Chemical System <br /> Review Date: 03/11/2024 <br /> BADGER <br /> 3/8" PIPING 19MSYSTEM MFG: BADGER FIRE PROTECTION UCH CONTROL HEAD ` <br /> EVo <br /> EREEVERETT <br /> 1/2" PIPING RANGE GUARD-6 GALLON TANK EIRE.TT. v <br /> Badger Everett Fire Dept.Permit Review <br /> CAPABLE FLOW POINTS: 18 ACTUAL FLOW POINTS USED: 13 Status:Approved <br /> 3/4" PIPING Fire Protection "SYSTEM HAS BEEN INSTALLED AND SHALL BE SERVICED AND Reviewed By:KBrown <br /> 03/11/2024 1:06:11 <br /> MAINTAINED TO UL300, NFPAI7A, NFPA96 STANDARDS AND PM <br /> MANUFACTURERS INSTRUCTIONS. <br />