Laserfiche WebLink
SOLAR PV SYSTEM DETAILS MODULE DATA BUSBAR CALCULATIONS FEEDER SCHEDULE <br /> TOTAL MODULE(S) 25 MODULE MODEL HANWHA Q.PEAK DUO MAIN PV BUSBAR LOADS TOTAL% O ENPHASE Q CABLES+#6 BARE EGC IN OPEN AIR <br /> BLK-M1--G10+405 200 40A 200 200 120%5100% (4)#12 THWN-2+(1)#10 GND IN 3/4"EMT <br /> TOTAL DC POWER 10.13kW vmpp 37.39V ® NOT USED <br /> OPERATING VOLTAGE 240V impp 10.32A CONDUIT CURRENT CALCULATIONS (2)#8 THWN-2+(1)#8 THWN-2 NEUT+(1)#10 GND IN 1"EMT <br /> voc 45.34V <br /> 11.17A #12 THWN-2 ALLOWABLE CURRENT 30A ® NOT USED <br /> MAX AC POWER OUT 7.25kVA ® NOT USED <br /> Voc TEMP COEFF -0.27%/"C CURRENT CARRYING CONDUCTORS 4 0 0 <br /> NOUSED <br /> MIN DESIGN TEMP -40°C ADJUSTMENT FACTOR 80% O T <br /> PV STRING SIZING DETAILS ADJUSTED ALLOWED CURRENT 24A ® NOT USED PUGET SOUND SOLAR <br /> STRING MAX MICROS 13 INVERTER DATA STRING MAX AC OUTPUT CURRENT 15.7A FLAG NOTES: 805 Rainier Ave S <br /> STRING MAX AC INVERTER MODEL ENPHASE IQ8PLUS-72-2-US �BACKFEEDING INTO MAIN PANEL IN COMPLIANCE WITH NEC <br /> CONTINUOUS OUTPUT 15.73A OVERCURRENT PROTECTION 2020 705.12(B)(3)(3)-SUM OF OCPD TO NOT EXCEED BUSBAR Seattle, WA 98144 <br /> SYSTEM MAX DC IN 60V 2 OMNI CABLE FOR MONITORING DEVICE,IN FEEDER PIPE#3 Tel: 206-706-1931 <br /> MICROINVERTER TOTAL 25 MAX CURRENT IN 15A MAX AC OUTPUT 125%SAFETY OCPD SIZE 3 NOT USED <br /> SYSTEM MAX AC MAX AC OUT 290VA "PV STRING MAX 19.7A 20A <br /> CONTINUOUS OUTPUT 30.25A MAX CURRENT OUT 1.21A "PV TOTAL 37.8A 40A NOT USED <br /> x <br /> NOT USED �o <br /> ioa <br /> ©NOT USED 3 y a <br /> o'k <br /> �o <br /> 1 DAYS <br /> O o00 <br /> z <br /> LEGEND <br /> GROUNDING QcM U o <br /> N O doh <br /> BREAKERV -p C _w <br /> i2 <br /> SOLAR MODULE 3 ... '.10 <br /> Z 0,a <br /> ❑J JUNCTION BOX > (D z w <br /> O PRODUCTION = W z'o i <br /> METER (,� u g <br /> OM NET METER <br /> FUSED AC 81w <br /> �- U) 81 <br /> o c <br /> DISCONNECT - <br /> UNFUSED AC o a <br /> 400A DISCONNECT o <br /> MI <br /> UTILITY MICROINVERTER zo R <br /> SERVICE r1 DC OPTIMIZER .g <br /> 3u15 <br /> v � <br /> F1U <br /> IQ COMBINER SPLIT BUS <br /> 'M� PANEL 2 <br /> O 200A MAIN <br /> 200A BUS <br /> SPLIT BUS 0 PRELIMINARY DESIGN 62623 <br /> 200A PANEL 1 REV DESCRIPTION DATE <br /> 20A <br /> 200A MAIN DRAWN BY NN <br /> 20A o 200A BUS CHECKED BY DR <br /> 15A o PROJECT#:20329 <br /> O SALES:JASON ASKEW <br /> Mi Mi STRING OF m m O o PM: DAN RODGERS <br /> 12 MODULES <br /> a PM CELL:(206)852-2832 <br /> 0 <br /> IQ 40A ELECTRICAL ONE LINE <br />€ M M M M O GATEWAY DIAGRAM <br /> STRING OF j <br /> 13 MODULES <br /> ROOF EXTERIOR EXISTING PV-102 <br />