• J <br /> Electricalwire Gas Supply Requirements <br /> ©WARNING AWARNING <br /> 1 <br /> Electrical Shock Hazard Explosion Hazard <br /> Plug into a grounded 3 prong outlet. Use a new CSA International approved gas supply line. <br /> Do not remove ground prong. Install a shut-off valve. <br /> Do not use an adapter. Securely tighten all gas connections. <br /> Do not use an extension cord. If connected to LP,have a qualified person make sure <br /> gas pressure does not exceed 14"(36 cm)water <br /> Failure to follow these instructions can result in death, column. <br /> fire,or electrical shock. <br /> Examples of a qualified person include: <br /> IMPORTANT.The range must be electrically grounded in licensed heating personnel, <br /> accordance with local codes and ordinances,or in the absence authorized gas company personnel,and <br /> of local codes,with the National Electrical Code,ANSI/NFPA 70 authorized service personnel. <br /> or Canadian Electrical Code,CSA C22.1. Failure to do so can result in death,explosion,or fire. <br /> This range is equipped with an electronic ignition system that will <br /> not operate if plugged into an outlet that is not properly polarized. Observe all governing codes and ordinances. <br /> If codes permit and a separate ground wire is used,it is IMPORTANT:This installation must conform with all local codes <br /> recommended that a qualified electrical installer determine that and ordinances.In the absence of local codes,installation must <br /> the ground path is adequate. conform with American National Standard,National Fuel Gas <br /> A copy of the above code standards can be obtained from: Code ANSI Z223.1 -latest edition or CAN/CGA B149-latest <br /> National Fire Protection Association edition. <br /> 1 Batterymarch Park IMPORTANT:Leak testing of the range must be conducted <br /> Quincy,MA 02169-7471 according to the manufacturer's instructions. <br /> CSA International <br /> 8501 East Pleasant Valley Road Hype of Gas <br /> Cleveland,OH 44131-5575 <br /> • A 120 volt,60 Hz.,AC only,15-amp fused,electrical circuit is Natural gas: <br /> required.A time-delay fuse or circuit breaker is also ■ This range is factory set for use with Natural gas.See"Gas <br /> recommended.It is recommended that a separate circuit Conversions"section.The modeVserial rating plate located <br /> serving only this range be provided. on the oven frame behind the top left side of the oven door <br /> • Electronic ignition systems operate within wide voltage limits, has information on the types of gas that can be used.If the <br /> but proper grounding and polarity are necessary.Check that types of gas listed do not include the type of gas available, <br /> the outlet provides 120-volt power and is correctly grounded. check with the local gas supplier. <br /> • This gas range is not required to be plugged into a GFCI LP gas conversion: <br /> (Ground-Fault Circuit Interrupter)outlet.It is recommended Conversion must be done by a qualified service technician. <br /> that you not plug an electric spark ignition gas range or any No attempt shall be made to convert the appliance from the gas <br /> other major appliance into a GFCI wall outlet as it may cause specified on the modeVserial rating plate for use with a different <br /> the GFCI to trip during normal cycling. gas without consulting the serving gas supplier.See"Gas <br /> • Performance of this range will not be affected if operated on a Conversions"section. <br /> GFCI-protected circuit.However,occasional nuisance <br /> tripping of the GFCI breaker is possible due to the normal <br /> operating nature of electronic gas ranges. <br /> • The wiring diagram is located on the back of the range in a <br /> clear plastic bag. <br /> NOTE:The metal chassis of the range must be grounded in <br /> order for the control panel to work.If the metal chassis of the <br /> range is not grounded,no keypads will operate.Check with a <br /> qualified electrician if you are in doubt as to whether the <br /> metal chassis of the range is grounded. <br /> 5 <br />