My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1602 HEWITT AVE VERIZON WIRELESS ANTENNAS 2024-10-24
>
Address Records
>
HEWITT AVE
>
1602
>
VERIZON WIRELESS ANTENNAS
>
1602 HEWITT AVE VERIZON WIRELESS ANTENNAS 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 2:52:04 PM
Creation date
7/31/2024 10:22:10 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1602
Tenant Name
VERIZON WIRELESS ANTENNAS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\VECTDR <br /> a EL) <br /> E n e l n E E R S Rs <br /> Project Number:U2350-944-231 NOV 3 0 2023 <br /> April 28,2023 CITY U EVERETT <br /> ACOM Consulting,Ina Permit Services <br /> 5200 SW Meadows Road,Suite 150 <br /> Lake Oswego,OR 97035 <br /> ATTENTION: Rick Matteson <br /> REFERENCE: SEA Deadwater Slough <br /> 1602 Hewitt Ave.,Everett,WA 98201 <br /> Antenna Mount Design <br /> Dear Rick, <br /> Per your request,we have reviewed the construction drawings prepared by your office for the proposed antenna and <br /> auxiliary equipment modifications,which include the addition of(2)microwave antennas and(1)ODU unit on(2)new <br /> antenna ballasted sled mounts on the concrete roof of the existing equipment shelter at the site listed above. In addition, <br /> we have reviewed the as-built drawings for the equipment shelter prepared by Fibrebond(Drawing No.:D-9700, <br /> Dated:February 26,2014). Please be advised as follows: <br /> Based upon our calculations and review of the documents noted above,we conclude that the antenna sled mount <br /> assemblies,as shown in the construction drawings,are adequate to support the loads associated with the proposed <br /> antennas and auxiliary equipment. Supporting calculations for the gravity and lateral loading on the proposed <br /> antennas,and an analysis of the capacity of the mounts are attached. <br /> The recommendations above are provided based upon calculations prepared by our office and information the client <br /> provided.A representative from Vector has not visited the site.The analysis and conclusions described above are limited <br /> to the members included in this report only and are based on the assumption that the supporting structure was properly <br /> designed and constructed,and has been properly maintained. Analysis of the existing equipment shelter is not part of the <br /> scope of this project.Vector Structural Engineering makes no claim as to the correctness of the original design or the <br /> current condition of the structure,which is assumed to be in good condition,free of damage or deterioration. The <br /> contractor shall verify the condition of the existing structure and shall notify Vector immediately should any damage, <br /> deterioration or discrepancies between the as-built condition of the existing structure and the assumed condition described <br /> in this report and on the construction drawings be found. <br /> We hope this meets your needs. If you have any further questions regarding this matter,please call this office at your <br /> convenience. <br /> Very truly yours, <br /> VECTOR STRUCTURAL ENGINEERING,LLC <br /> s LIND 40 <br /> �' C <br /> J �1k' p WA,4�f 4 <br /> Wells L.Holmes,S.E. A t� � . <br /> Project Engineer N,71 it <br /> ., <br /> WLH/chk f 0� <br /> 4:1k, IYAL�NCs` <br /> Enclosures <br /> 04/28/2023 <br /> 651 W Galena Park Blvd,Suite 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.