ELECTRICAL SYMBOL LIST
<br />SYMBOL:
<br />TAG:
<br />DESCRIPTION:
<br />GB
<br />GB
<br />GROUNDBUS
<br />ail
<br />IBT
<br />INTERSYSTEM BONDING TERMINATION
<br />O
<br />❑E
<br />ECONN
<br />ELECTRICAL CONNECTION
<br />SJB
<br />J
<br />JUNCTION BOX
<br />FB-#
<br />FLOOR BOX- DUPLEX RECEPTACLE
<br />FB-#
<br />FLOOR BOX- DUAL COMPARTMENT
<br />®
<br />FB-#
<br />FLOOR BOX - MULTISERVICE
<br />iY
<br />FB-#
<br />FLOOR - SERVICE FITTING
<br />RI
<br />RI -TECH
<br />TECHNOLOGY OUTLET ROUGH -IN
<br />®RI
<br />RI-TECH-C.
<br />TECHNOLOGY ROUGH -IN, CEILING
<br />W/RI
<br />RI-TECH-W
<br />TECHNOLOGY ROUGH -IN, WALL PHONE
<br />ON
<br />RI -TV
<br />TV ANTENNA OUTLET ROUGH -IN
<br />11=31373
<br />WM-#
<br />MULTI OUTLET SYSTEM
<br />WW-#
<br />ELECTRICAL WIREWAY W DEVICES SHOWN
<br />DEM
<br />DEM
<br />ENERGY METER
<br />DPM
<br />DPM
<br />DIGITAL POWER METER
<br />FIT—D—Ml
<br />ITDM
<br />IMPULSE -TOTALIZING DEMAND
<br />EEM
<br />EEM
<br />EXTERNAL ENERGY METER
<br />PQ
<br />PQM
<br />POWER QUALITY METER
<br />CPC
<br />CPC
<br />CONTROL POWER CABINET
<br />ES
<br />ES
<br />EMERGENCY STOP, N.C. CONTACT
<br />EPO
<br />EPO
<br />EMERGENCY STOP, N.O. CONTACT
<br />®
<br />FA -LA
<br />LAMPANNUNCIATOR
<br />PB
<br />PB
<br />MOMENTARY PUSHBUTTON OPERATOR
<br />a
<br />PANEL'###'
<br />PANELBOARD- RECESS MOUNT
<br />O
<br />PANEL'###'
<br />PANELBOARD- SURFACE MOUNT
<br />O m
<br />MX-#/MS-#
<br />MANUAL SWITCH/STARTER/COMBINATION
<br />/CB -#/CS-#
<br />STARTER/ CIRCUIT BREAKER. REFER TO
<br />DISC/STA SCHEDULE
<br />II
<br />IPP_f
<br />ISOLATED POWER PANEL
<br />MG
<br />MG
<br />MASTER GROUND STATION MODULE
<br />PM
<br />PM
<br />OPERATING ROOM POWER MODULE
<br />rRIM1
<br />RIM
<br />REMOTE LINE ISOLATION MONITOR
<br />RAS
<br />RAS
<br />REMOTE ANNUNCIATOR STATION
<br />InIPC-#
<br />INTEGRATED POWER CENTER
<br />®
<br />TR-WDTR-#
<br />TRANSFORMER. REFER TO
<br />TRANSFORMER SCHEDULE
<br />®
<br />MPC-#
<br />PACKAGED POWER CENTER
<br />C3
<br />CB-#
<br />CIRCUIT BREAKER- SURFACE MOUNTED.
<br />REFER TO DISC/STA SCHEDULE
<br />II
<br />CB-#
<br />CIRCUIT BREAKER - FLUSH MOUNTED.
<br />REFER TO DISC/STA SCHEDULE
<br />pl
<br />DS-#/FDS-NDSS-#
<br />DISCONNECT. REFER TO DISC/STA SCHEDULE
<br />MD -SD-#
<br />OI
<br />MOBILE DIAGNOSTICS SERVICE DISCONNECT.
<br />REFER TO DISC/STA SCHEDULE
<br />®
<br />BD-4
<br />BUSWAY
<br />ial
<br />BCS-#
<br />BUSS PLUG - COMBINATION STARTER.
<br />REFER TO DISC/STA SCHEDULE
<br />0
<br />BP-#
<br />BUSS PLUG- CIRCUIT BREAKER.
<br />REFER TO DISC/STA SCHEDULE
<br />i�
<br />BFP-#
<br />BUSS PLUG - FUSIBLE DISCONNECT.
<br />REFER TO DISC/STA SCHEDULE
<br />i1311#
<br />BD-REC-#
<br />BUSSWAY RECEPTACLE UNIT.
<br />REFER TO DISC/STA SCHEDULE
<br />ELECTRICAL
<br />SYMBOL LIST
<br />SYMBOL:
<br />TAG:
<br />DESCRIPTION:
<br />0=0
<br />REC-DUP-O
<br />DUPLEX RECEPTACLE CONTROLLED BY
<br />OCCUPANCY
<br />0=0
<br />REC-QUAD-O
<br />QUAD RECEPTACLE CONTROLLED BY
<br />OCCUPANCY
<br />=0
<br />REC-DUP
<br />DUPLEX RECEPTACLE, 125V
<br />REC-DUP-GFI
<br />DUPLEX GFI RECEPTACLE, 125V
<br />REC-DUP-GFI-R
<br />©
<br />GROUND FAULT DEVICE
<br />REC-DUP-WP
<br />W%@
<br />DUPLEX GFI WEATHERPROOF RECEPTACLE 125V
<br />REC-TAMP-QUAD
<br />4>
<br />QUAD RECEPTACLE, TAMPERPROOF, 125V
<br />REC-QUAD
<br />=N
<br />QUAD RECEPTACLE, 125V
<br />4
<br />REC-QUAD-GFI
<br />QUAD GFI RECEPTACLE, 125V
<br />REC-QUAD-USB
<br />U=0
<br />QUAD RECEPTACLE, USB 125V
<br />REC-QUAD-WP
<br />W�
<br />QUAD GFI WEATHERPROOF RECEPTACLE, 125V
<br />REC-DUP-PED
<br />RECEPTACLE -PEDESTAL STYLE
<br />REC-PED-QUAD
<br />RECEPTACLE -PEDESTAL STYLE
<br />REC-FB-#
<br />FLOOR BOX - POKE THRU, 125V
<br />#®
<br />REC-Z#
<br />IEC PIN AND SLEEVE RECEPTACLE, 600V
<br />PP#
<br />POWER POLE
<br />ELECTRICAL SYMBOL LIST
<br />SYMBOL:
<br />TAG:
<br />DESCRIPTION:
<br />S
<br />SW-1P
<br />SWITCH -SINGLE POLE
<br />S60
<br />SW-iP-060
<br />SWITCH - LOCAL TIMER -SPRING WOUND
<br />ST
<br />SW-IP-ADJ
<br />SWITCH - LOCAL TIMER - USER ADJUSTABLE
<br />S6
<br />SW-3W
<br />SWITCH - THREE WAY
<br />S4
<br />SW4W
<br />SWITCH - FOUR WAY
<br />DF
<br />SW-D-FL
<br />DIMMER- FLUORESCENT BALLAST
<br />D
<br />SW-D-LED
<br />DIMMER -LED
<br />DO
<br />SW -OD
<br />DIMMER- WALL DIMMER
<br />OCCUPANCYSENSOR
<br />LS
<br />SW-LS
<br />DAYLIGHT LEVEL SENSOR
<br />LS
<br />SW-LS-3Z
<br />DAYLIGHT LEVEL SENSOR -3ZONE
<br />3
<br />LSD
<br />SW-LS-D
<br />DAYLIGHT LEVEL SENSOR- 1 ZONE DIMMING
<br />LS 3D
<br />SW-LS-D-3Z
<br />DAYLIGHT LEVEL SENSOR-3 ZONE DIMMING
<br />SW-LS-PC
<br />PC
<br />PHOTOCELL
<br />OC
<br />SW-OC-D
<br />OCCUPANCY SENSOR - DUAL TECHNOLOGY
<br />D
<br />OC
<br />SW-OC-D-W
<br />OCCUPANCY SENSOR - DUAL
<br />D
<br />TECHNOLOGY -WALL MOUNTED
<br />Sp
<br />SW-OC-P-O
<br />SWITCH- OCCUPANCY SENSOR
<br />WALL SWITCH
<br />SO2
<br />SW-OC-P-02
<br />SWITCH- OCCUPANCY SENSOR AND
<br />DUAL SWITCH
<br />TC
<br />TC-#
<br />TIME SWITCH
<br />ELECTRICAL SYMBOL LIST
<br />SYMBOL: TAG: DESCRIPTION:
<br />O
<br />LINEAR LUMINAIRES
<br />TROFFER
<br />WALL SCONCE LUMINAIRE
<br />O
<br />DOWNLIGHT LUMINAIRE
<br /><O
<br />AIMABLE OR WALL WASH LUMINAIRE
<br />REFER TO
<br />LUMINAIRE
<br />INDUSTRIAL LUMINAIRE
<br />I 9
<br />2 _y
<br />SCHEDULE
<br />WALL BRACKET LUMINAIRE
<br />D 0
<br />POLE MOUNTED LUMINAIRE
<br />®
<br />SINGLE FACE EXIT SIGN
<br />®
<br />DOUBLE FACE EXIT SIGN
<br />T&
<br />WALL/CEILING EMERGENCY EXIT SIGN
<br />4C:P
<br />EMERGENCY UNIT
<br />ELECTRICAL ABBREVIATION KEY
<br />ABBR:
<br />DESCRIPTION:
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />C
<br />CONDUIT
<br />GFI
<br />GROUND FAULT INTERRUPTER
<br />N.C.
<br />NORMALLYCLOSED
<br />NIC
<br />NOT IN CONTRACT
<br />N.O.
<br />NORMALLYOPEN
<br />SV
<br />SOLENOID VALVE
<br />TYP
<br />TYPICAL
<br />UNO
<br />UNLESS NOTED OTHERWISE
<br />VIEW KEY
<br />NAME —LEVEL NAME
<br />INDICATES NOTE USED TO DESCRIBE
<br />—HEIGHT ABOVE
<br />ADDITIONAL INFORMATION ABOUT
<br />PROJECT 0'- 0"
<br />WORK REQUIRED, SPECIFIC TO THE
<br />SHEET AND/OR DETAIL
<br />INDICATES DIRECTION OF TRUE NORTH
<br />PLAN OR DETAIL NUMBER
<br />PLAN OR DETAIL NAME
<br />VIEW NAME
<br />PLAN OR DETAIL SCALE
<br />tip Rt�
<br />INDICATES SIMILAR DETAIL
<br />Sim REFERENCED IN MULTIPLE LOCATIONS
<br />DETAIL REFERRED TO BY SECTION CUT
<br />M101 SHEET DETAIL IS LOCATED ON
<br />INDICATES SIMILAR DETAIL
<br />REFERENCED IN MULTIPLE LOCATIONS
<br />SI
<br />DETAIL REFERRED TO BY ELEVATION
<br />4
<br />3 T101_ SHEET DETAIL IS LOCATED ON
<br />LINE TYPE KEY:
<br />NEW WORK BY THIS CONTRACTOR
<br />(DARK SOLID LINE)
<br />— — — —NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
<br />(DARK LONG DASHED LINE)
<br />NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN
<br />(LIGHT SOLID LINE)
<br />— — — — — — — EXISTING TO BE REMOVED BY THIS CONTRACTOR
<br />(DARK SHORT DASHED LINE)
<br />ELECTRICAL GENERAL NOTES:
<br />1. ##-### INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES OR
<br />SPECIFICATION. REFER TO DRAWINGS CONTAINING ELECTRICAL SCHEDULES. PERMANENT
<br />NAMEPLATE SHALL MATCH FINAL EQUIPMENT NOMENCLATURE, NOT ELECTRICAL
<br />EQUIPMENT TAG NAME, REFER TO SPECIFICATIONS.
<br />2. "NL" INDICATES LUMINAIRE IS UNSWITCHED FOR NIGHT LIGHT.
<br />3. SHADED LUMINAIRE OR DEVICE INDICATES LUMINAIRE OR DEVICE IS CONNECTED TO AN
<br />EMERGENCY CIRCUIT.
<br />LUMINAIRE KEY:
<br />F1=FIXTURE TAG
<br />1 = CIRCUIT NUMBER
<br />LUMINAIRE a= SWITCH DESIGNATION
<br />NIL = SUBSCRIPT (IF APPLICABLE)
<br />DEVICE KEY: *IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS
<br />INFORMATION. EX: F1 11 / a / NIL
<br />DEVICEII A- MOUNTING (IF APPLICABLE)
<br />1 = CIRCUIT NUMBER
<br />*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS
<br />INFORMATION. EX: A 11
<br />ELECTRICAL MOUNTING SUBSCRIPT KEY:
<br />A MOUNT AT 6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH
<br />C MOUNTATCEILING
<br />H MOUNT ORIENTED HORIZONTALLY
<br />L MOUNT IN CASEWORK
<br />M MOUNT IN MODULAR FURNITURE
<br />R MOUNT IN SURFACE RACEWAY
<br />EWC ELECTRIC WATER COOLER
<br />LUMINAIRE SYMBOL KEY
<br />SYMBOL:
<br />DESCRIPTION:
<br />O
<br />NORMAL BRANCH LUMINAIRE
<br />® ®
<br />EMERGENCY BRANCH LUMINAIRE
<br />UNSWITCHED FOR NIGHT LIGHT, UNLESS NOTED 'SE'
<br />CONTRACTOR ABBREVIATION KEY
<br />ABBR:
<br />DESCRIPTION:
<br />A.C.
<br />ASBESTOS ABATEMENT CONTRACTOR
<br />A.T.C.
<br />AUTOMATIC TEMPERATURE CONTROL CONTRACTOR
<br />A.V.C.
<br />AUDIONISUAL CONTRACTOR
<br />C.C.
<br />CIVIL CONTRACTOR
<br />C.M.
<br />CONSTRUCTION MANAGER
<br />E.C.
<br />ELECTRICAL CONTRACTOR
<br />F.P.C.
<br />FIRE PROTECTION CONTRACTOR
<br />F.S.C.
<br />FOOD SERVICE CONTRACTOR
<br />G.C.
<br />GENERAL CONTRACTOR
<br />H.C.
<br />HEATING CONTRACTOR
<br />M.C.
<br />MECHANICAL CONTRACTOR
<br />N.C.C.
<br />NURSE CALL CONTRACTOR
<br />P.C.
<br />PLUMBING CONTRACTOR
<br />S.C.
<br />SECURITY CONTRACTOR
<br />T.C.
<br />TECHNOLOGY CONTRACTOR
<br />T.C.C.
<br />TEMPERATURE CONTROLS CONTRACTOR
<br />V.C.
<br />VENTILATION CONTRACTOR
<br />ELECTRICAL INSTALLATION NOTES:
<br />1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR
<br />ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS
<br />ON THIS PAGE FOR ADDITIONAL INFORMATION.
<br />2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE
<br />WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR
<br />BRANCH CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN
<br />EACH PHASE.
<br />3. FLUSH MOUNT ALL LIGHTING CONTROL DEVICES AT -42" FROM FLOOR (CENTERLINE
<br />DIMENSION), EXCEPT WHERE OTHERWISE NOTED. DEVICES MAY BE SURFACE MOUNTED
<br />WHEN CONDUIT IS SPECIFIED EXPOSED.
<br />4. FLUSH MOUNT ALL DUPLEX RECEPTACLES AND TECHNOLOGY OUTLETS AT +18" FROM
<br />FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. RECEPTACLES AND
<br />OUTLETS MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED.
<br />5. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL
<br />BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF
<br />THROUGH -PENETRATION FIRESTOPS.
<br />6. CONNECTION FOR ELECTRIC WATER COOLERS (EWC) SHALL BE A JUNCTION BOX
<br />CONCEALED BEHIND WATER COOLER ACCESS PLATE OR BE A GFI RECEPTACLE LOCATED
<br />DIRECTLY BELOW AND CENTERED ON EWC. CONTRACTOR SHALL VERIFY TYPE OF EWC TO
<br />BE INSTALLED.
<br />7. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND
<br />EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES
<br />IN CEILING TILE PATTERN. SMOKE DETECTORS AND OCCUPANCYNACANCY SENSORS
<br />SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN
<br />GRILLE.
<br />B. CONTRACTOR SHALL VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT
<br />LOCATIONS WITH ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS.
<br />PRIOR TO MAKING THE ACTUAL ELECTRICAL INSTALLATION, THIS CONTRACTOR SHALL
<br />ADJUST RECEPTACLES, OUTLETS, OR CONNECTION LOCATIONS TO ACCOMMODATE
<br />FURNITURE AND/OR EQUIPMENT.
<br />9. ELECTRICAL AND TECHNOLOGY EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF,
<br />OPERATION OF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL
<br />MOUNTING OF ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT, ON EQUIPMENT
<br />SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE OTHER
<br />CONTRACTOR.
<br />10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL
<br />OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE
<br />EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR
<br />SEALED INTO OPENINGS.
<br />11. ALL WELDING SHALL BE ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS.
<br />CONTRACTOR SHALL FURNISH TO THE ARCHITECT/ENGINEER CERTIFICATES QUALIFYING
<br />EACH WELDER, PRIOR TO START OF WORK. THE ARCHITECT/ENGINEER RESERVES THE
<br />RIGHT TO REQUIRE QUALIFYING DEMONSTRATION, AT THE CONTRACTOR'S EXPENSE, OF
<br />ANY WELDERS ASSIGNED TO THE JOB.
<br />12. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY
<br />AUDIONISUAL, AND OTHER ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
<br />MOUNTED DEVICES, OTHER THAN SPRINKLERS.
<br />13. ELECTRICAL IDENTIFICATION. REFER TO SPECIFICATION SECTION FOR COLOR/LABEL
<br />REQUIREMENTS FOR CONDUIT, BOX, CABLEN/1RE, AND EQUIPMENT.
<br />ELECTRICAL RENOVATION NOTES:
<br />THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
<br />TO, LIGHTING, POWER, AND SYSTEMS.
<br />1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD
<br />SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND
<br />REPORT ANY CONFLICTS BEFORE PROCEEDING.
<br />2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. VERIFY EXISTING
<br />CONDITIONS AND REPORT ANY CONFLICTS WITH NEW WORK BEFORE STARTING WORK.
<br />3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR CABLE TRAY, BUSWAY AND CONDUITS
<br />BEFORE FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING
<br />FIELD CONDITIONS.
<br />4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS/HER WORK
<br />AND SHALL NOTIFY THE GENERAL CONTRACTOR PRIOR TO BIDDING IF OTHER UTILITIES ARE
<br />REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF
<br />WORK.
<br />5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF
<br />ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS.
<br />CONTRACTORS SHALL NOTIFY THE GC OF AFFECTED AREAS PRIOR TO BIDDING.
<br />6. GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS,
<br />CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL
<br />CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO
<br />BIDDING.
<br />7. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW
<br />EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER
<br />ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES
<br />NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO
<br />ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.
<br />�I,blc LAWRENCE
<br />GROUP
<br />St' Louis
<br />319 North 4th Street
<br />Suite 1000
<br />St. Louis, Missouri 63102
<br />(314)231-5700
<br />PROJECTTEAM:
<br />GENERAL CONTRACTOR:
<br />TBD
<br />PROFESSIONAL ENGINEER:
<br />NMEG
<br />IMEG
<br />7600 E Orchard Road, Suite 250-S
<br />Greenwood Village, CO 80111
<br />Phone: 303.796.6000
<br />MEG Project No.: 23000048.10
<br />PROFESSIONAL SEAL:
<br />It. Do
<br />opa
<br />o�
<br />'4 51988
<br />�sS�UNAL>�
<br />05/24/2023
<br />PROJECTTITLE:
<br />U
<br />�
<br />O
<br />L.L
<br />H
<br />Z 0
<br />W ■
<br />� J
<br />O _A
<br />Of
<br />d
<br />(1W'
<br />H
<br />Z
<br />Q
<br />Z
<br />W
<br />H
<br />J 06 U
<br />L!
<br />W
<br />0
<br />O
<br />U
<br />L0
<br />M-
<br />W
<br />CO
<br />J
<br />0
<br />M
<br />N
<br />06
<br />W
<br />N
<br />TM1e Professional Architect's seal affixetl to this sheet
<br />applies only to the materiel end Items shown on this
<br />—1, All drawings i 11- b Ms or id prepared
<br />y
<br />exsibrl,g,,t, seal hM1ell not be rxsn newlytl prepared by
<br />this architect, and Ihla architect expressly discbims any
<br />and all responsibility for shM1 ns, platlrawirgs or
<br />tlocumenis not exhibiting this
<br />this seal.
<br />This tl,M W end details on it are the We property of die
<br />—hi." and may be need for this spectlic project only.
<br />It shall not be band, copied or repmtluced, in whole or
<br />pad, or for any other purpose or project wilhout the
<br />written consent of the ..hit-.
<br />No Description Date
<br />SHEET TITLE'.
<br />ELECTRICAL COVER
<br />SHEET
<br />PROJECT NUMBER:
<br />SHEET NUMBER:
<br />2021932.001
<br />omwn Rr
<br />ARD
<br />Issue Dale:
<br />O
<br />May 23, 2023
<br />
|