Laserfiche WebLink
ELECTRICAL SYMBOL LIST <br />SYMBOL: <br />TAG: <br />DESCRIPTION: <br />GB <br />GB <br />GROUNDBUS <br />ail <br />IBT <br />INTERSYSTEM BONDING TERMINATION <br />O <br />❑E <br />ECONN <br />ELECTRICAL CONNECTION <br />SJB <br />J <br />JUNCTION BOX <br />FB-# <br />FLOOR BOX- DUPLEX RECEPTACLE <br />FB-# <br />FLOOR BOX- DUAL COMPARTMENT <br />® <br />FB-# <br />FLOOR BOX - MULTISERVICE <br />iY <br />FB-# <br />FLOOR - SERVICE FITTING <br />RI <br />RI -TECH <br />TECHNOLOGY OUTLET ROUGH -IN <br />®RI <br />RI-TECH-C. <br />TECHNOLOGY ROUGH -IN, CEILING <br />W/RI <br />RI-TECH-W <br />TECHNOLOGY ROUGH -IN, WALL PHONE <br />ON <br />RI -TV <br />TV ANTENNA OUTLET ROUGH -IN <br />11=31373 <br />WM-# <br />MULTI OUTLET SYSTEM <br />WW-# <br />ELECTRICAL WIREWAY W DEVICES SHOWN <br />DEM <br />DEM <br />ENERGY METER <br />DPM <br />DPM <br />DIGITAL POWER METER <br />FIT—D—Ml <br />ITDM <br />IMPULSE -TOTALIZING DEMAND <br />EEM <br />EEM <br />EXTERNAL ENERGY METER <br />PQ <br />PQM <br />POWER QUALITY METER <br />CPC <br />CPC <br />CONTROL POWER CABINET <br />ES <br />ES <br />EMERGENCY STOP, N.C. CONTACT <br />EPO <br />EPO <br />EMERGENCY STOP, N.O. CONTACT <br />® <br />FA -LA <br />LAMPANNUNCIATOR <br />PB <br />PB <br />MOMENTARY PUSHBUTTON OPERATOR <br />a <br />PANEL'###' <br />PANELBOARD- RECESS MOUNT <br />O <br />PANEL'###' <br />PANELBOARD- SURFACE MOUNT <br />O m <br />MX-#/MS-# <br />MANUAL SWITCH/STARTER/COMBINATION <br />/CB -#/CS-# <br />STARTER/ CIRCUIT BREAKER. REFER TO <br />DISC/STA SCHEDULE <br />II <br />IPP_f <br />ISOLATED POWER PANEL <br />MG <br />MG <br />MASTER GROUND STATION MODULE <br />PM <br />PM <br />OPERATING ROOM POWER MODULE <br />rRIM1 <br />RIM <br />REMOTE LINE ISOLATION MONITOR <br />RAS <br />RAS <br />REMOTE ANNUNCIATOR STATION <br />InIPC-# <br />INTEGRATED POWER CENTER <br />® <br />TR-WDTR-# <br />TRANSFORMER. REFER TO <br />TRANSFORMER SCHEDULE <br />® <br />MPC-# <br />PACKAGED POWER CENTER <br />C3 <br />CB-# <br />CIRCUIT BREAKER- SURFACE MOUNTED. <br />REFER TO DISC/STA SCHEDULE <br />II <br />CB-# <br />CIRCUIT BREAKER - FLUSH MOUNTED. <br />REFER TO DISC/STA SCHEDULE <br />pl <br />DS-#/FDS-NDSS-# <br />DISCONNECT. REFER TO DISC/STA SCHEDULE <br />MD -SD-# <br />OI <br />MOBILE DIAGNOSTICS SERVICE DISCONNECT. <br />REFER TO DISC/STA SCHEDULE <br />® <br />BD-4 <br />BUSWAY <br />ial <br />BCS-# <br />BUSS PLUG - COMBINATION STARTER. <br />REFER TO DISC/STA SCHEDULE <br />0 <br />BP-# <br />BUSS PLUG- CIRCUIT BREAKER. <br />REFER TO DISC/STA SCHEDULE <br />i� <br />BFP-# <br />BUSS PLUG - FUSIBLE DISCONNECT. <br />REFER TO DISC/STA SCHEDULE <br />i1311# <br />BD-REC-# <br />BUSSWAY RECEPTACLE UNIT. <br />REFER TO DISC/STA SCHEDULE <br />ELECTRICAL <br />SYMBOL LIST <br />SYMBOL: <br />TAG: <br />DESCRIPTION: <br />0=0 <br />REC-DUP-O <br />DUPLEX RECEPTACLE CONTROLLED BY <br />OCCUPANCY <br />0=0 <br />REC-QUAD-O <br />QUAD RECEPTACLE CONTROLLED BY <br />OCCUPANCY <br />=0 <br />REC-DUP <br />DUPLEX RECEPTACLE, 125V <br />REC-DUP-GFI <br />DUPLEX GFI RECEPTACLE, 125V <br />REC-DUP-GFI-R <br />© <br />GROUND FAULT DEVICE <br />REC-DUP-WP <br />W%@ <br />DUPLEX GFI WEATHERPROOF RECEPTACLE 125V <br />REC-TAMP-QUAD <br />4> <br />QUAD RECEPTACLE, TAMPERPROOF, 125V <br />REC-QUAD <br />=N <br />QUAD RECEPTACLE, 125V <br />4 <br />REC-QUAD-GFI <br />QUAD GFI RECEPTACLE, 125V <br />REC-QUAD-USB <br />U=0 <br />QUAD RECEPTACLE, USB 125V <br />REC-QUAD-WP <br />W� <br />QUAD GFI WEATHERPROOF RECEPTACLE, 125V <br />REC-DUP-PED <br />RECEPTACLE -PEDESTAL STYLE <br />REC-PED-QUAD <br />RECEPTACLE -PEDESTAL STYLE <br />REC-FB-# <br />FLOOR BOX - POKE THRU, 125V <br />#® <br />REC-Z# <br />IEC PIN AND SLEEVE RECEPTACLE, 600V <br />PP# <br />POWER POLE <br />ELECTRICAL SYMBOL LIST <br />SYMBOL: <br />TAG: <br />DESCRIPTION: <br />S <br />SW-1P <br />SWITCH -SINGLE POLE <br />S60 <br />SW-iP-060 <br />SWITCH - LOCAL TIMER -SPRING WOUND <br />ST <br />SW-IP-ADJ <br />SWITCH - LOCAL TIMER - USER ADJUSTABLE <br />S6 <br />SW-3W <br />SWITCH - THREE WAY <br />S4 <br />SW4W <br />SWITCH - FOUR WAY <br />DF <br />SW-D-FL <br />DIMMER- FLUORESCENT BALLAST <br />D <br />SW-D-LED <br />DIMMER -LED <br />DO <br />SW -OD <br />DIMMER- WALL DIMMER <br />OCCUPANCYSENSOR <br />LS <br />SW-LS <br />DAYLIGHT LEVEL SENSOR <br />LS <br />SW-LS-3Z <br />DAYLIGHT LEVEL SENSOR -3ZONE <br />3 <br />LSD <br />SW-LS-D <br />DAYLIGHT LEVEL SENSOR- 1 ZONE DIMMING <br />LS 3D <br />SW-LS-D-3Z <br />DAYLIGHT LEVEL SENSOR-3 ZONE DIMMING <br />SW-LS-PC <br />PC <br />PHOTOCELL <br />OC <br />SW-OC-D <br />OCCUPANCY SENSOR - DUAL TECHNOLOGY <br />D <br />OC <br />SW-OC-D-W <br />OCCUPANCY SENSOR - DUAL <br />D <br />TECHNOLOGY -WALL MOUNTED <br />Sp <br />SW-OC-P-O <br />SWITCH- OCCUPANCY SENSOR <br />WALL SWITCH <br />SO2 <br />SW-OC-P-02 <br />SWITCH- OCCUPANCY SENSOR AND <br />DUAL SWITCH <br />TC <br />TC-# <br />TIME SWITCH <br />ELECTRICAL SYMBOL LIST <br />SYMBOL: TAG: DESCRIPTION: <br />O <br />LINEAR LUMINAIRES <br />TROFFER <br />WALL SCONCE LUMINAIRE <br />O <br />DOWNLIGHT LUMINAIRE <br /><O <br />AIMABLE OR WALL WASH LUMINAIRE <br />REFER TO <br />LUMINAIRE <br />INDUSTRIAL LUMINAIRE <br />I 9 <br />2 _y <br />SCHEDULE <br />WALL BRACKET LUMINAIRE <br />D 0 <br />POLE MOUNTED LUMINAIRE <br />® <br />SINGLE FACE EXIT SIGN <br />® <br />DOUBLE FACE EXIT SIGN <br />T& <br />WALL/CEILING EMERGENCY EXIT SIGN <br />4C:P <br />EMERGENCY UNIT <br />ELECTRICAL ABBREVIATION KEY <br />ABBR: <br />DESCRIPTION: <br />AFF <br />ABOVE FINISHED FLOOR <br />C <br />CONDUIT <br />GFI <br />GROUND FAULT INTERRUPTER <br />N.C. <br />NORMALLYCLOSED <br />NIC <br />NOT IN CONTRACT <br />N.O. <br />NORMALLYOPEN <br />SV <br />SOLENOID VALVE <br />TYP <br />TYPICAL <br />UNO <br />UNLESS NOTED OTHERWISE <br />VIEW KEY <br />NAME —LEVEL NAME <br />INDICATES NOTE USED TO DESCRIBE <br />—HEIGHT ABOVE <br />ADDITIONAL INFORMATION ABOUT <br />PROJECT 0'- 0" <br />WORK REQUIRED, SPECIFIC TO THE <br />SHEET AND/OR DETAIL <br />INDICATES DIRECTION OF TRUE NORTH <br />PLAN OR DETAIL NUMBER <br />PLAN OR DETAIL NAME <br />VIEW NAME <br />PLAN OR DETAIL SCALE <br />tip Rt� <br />INDICATES SIMILAR DETAIL <br />Sim REFERENCED IN MULTIPLE LOCATIONS <br />DETAIL REFERRED TO BY SECTION CUT <br />M101 SHEET DETAIL IS LOCATED ON <br />INDICATES SIMILAR DETAIL <br />REFERENCED IN MULTIPLE LOCATIONS <br />SI <br />DETAIL REFERRED TO BY ELEVATION <br />4 <br />3 T101_ SHEET DETAIL IS LOCATED ON <br />LINE TYPE KEY: <br />NEW WORK BY THIS CONTRACTOR <br />(DARK SOLID LINE) <br />— — — —NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR <br />(DARK LONG DASHED LINE) <br />NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN <br />(LIGHT SOLID LINE) <br />— — — — — — — EXISTING TO BE REMOVED BY THIS CONTRACTOR <br />(DARK SHORT DASHED LINE) <br />ELECTRICAL GENERAL NOTES: <br />1. ##-### INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES OR <br />SPECIFICATION. REFER TO DRAWINGS CONTAINING ELECTRICAL SCHEDULES. PERMANENT <br />NAMEPLATE SHALL MATCH FINAL EQUIPMENT NOMENCLATURE, NOT ELECTRICAL <br />EQUIPMENT TAG NAME, REFER TO SPECIFICATIONS. <br />2. "NL" INDICATES LUMINAIRE IS UNSWITCHED FOR NIGHT LIGHT. <br />3. SHADED LUMINAIRE OR DEVICE INDICATES LUMINAIRE OR DEVICE IS CONNECTED TO AN <br />EMERGENCY CIRCUIT. <br />LUMINAIRE KEY: <br />F1=FIXTURE TAG <br />1 = CIRCUIT NUMBER <br />LUMINAIRE a= SWITCH DESIGNATION <br />NIL = SUBSCRIPT (IF APPLICABLE) <br />DEVICE KEY: *IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS <br />INFORMATION. EX: F1 11 / a / NIL <br />DEVICEII A- MOUNTING (IF APPLICABLE) <br />1 = CIRCUIT NUMBER <br />*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS <br />INFORMATION. EX: A 11 <br />ELECTRICAL MOUNTING SUBSCRIPT KEY: <br />A MOUNT AT 6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH <br />C MOUNTATCEILING <br />H MOUNT ORIENTED HORIZONTALLY <br />L MOUNT IN CASEWORK <br />M MOUNT IN MODULAR FURNITURE <br />R MOUNT IN SURFACE RACEWAY <br />EWC ELECTRIC WATER COOLER <br />LUMINAIRE SYMBOL KEY <br />SYMBOL: <br />DESCRIPTION: <br />O <br />NORMAL BRANCH LUMINAIRE <br />® ® <br />EMERGENCY BRANCH LUMINAIRE <br />UNSWITCHED FOR NIGHT LIGHT, UNLESS NOTED 'SE' <br />CONTRACTOR ABBREVIATION KEY <br />ABBR: <br />DESCRIPTION: <br />A.C. <br />ASBESTOS ABATEMENT CONTRACTOR <br />A.T.C. <br />AUTOMATIC TEMPERATURE CONTROL CONTRACTOR <br />A.V.C. <br />AUDIONISUAL CONTRACTOR <br />C.C. <br />CIVIL CONTRACTOR <br />C.M. <br />CONSTRUCTION MANAGER <br />E.C. <br />ELECTRICAL CONTRACTOR <br />F.P.C. <br />FIRE PROTECTION CONTRACTOR <br />F.S.C. <br />FOOD SERVICE CONTRACTOR <br />G.C. <br />GENERAL CONTRACTOR <br />H.C. <br />HEATING CONTRACTOR <br />M.C. <br />MECHANICAL CONTRACTOR <br />N.C.C. <br />NURSE CALL CONTRACTOR <br />P.C. <br />PLUMBING CONTRACTOR <br />S.C. <br />SECURITY CONTRACTOR <br />T.C. <br />TECHNOLOGY CONTRACTOR <br />T.C.C. <br />TEMPERATURE CONTROLS CONTRACTOR <br />V.C. <br />VENTILATION CONTRACTOR <br />ELECTRICAL INSTALLATION NOTES: <br />1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR <br />ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS <br />ON THIS PAGE FOR ADDITIONAL INFORMATION. <br />2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE <br />WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR <br />BRANCH CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN <br />EACH PHASE. <br />3. FLUSH MOUNT ALL LIGHTING CONTROL DEVICES AT -42" FROM FLOOR (CENTERLINE <br />DIMENSION), EXCEPT WHERE OTHERWISE NOTED. DEVICES MAY BE SURFACE MOUNTED <br />WHEN CONDUIT IS SPECIFIED EXPOSED. <br />4. FLUSH MOUNT ALL DUPLEX RECEPTACLES AND TECHNOLOGY OUTLETS AT +18" FROM <br />FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. RECEPTACLES AND <br />OUTLETS MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED. <br />5. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL <br />BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF <br />THROUGH -PENETRATION FIRESTOPS. <br />6. CONNECTION FOR ELECTRIC WATER COOLERS (EWC) SHALL BE A JUNCTION BOX <br />CONCEALED BEHIND WATER COOLER ACCESS PLATE OR BE A GFI RECEPTACLE LOCATED <br />DIRECTLY BELOW AND CENTERED ON EWC. CONTRACTOR SHALL VERIFY TYPE OF EWC TO <br />BE INSTALLED. <br />7. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND <br />EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES <br />IN CEILING TILE PATTERN. SMOKE DETECTORS AND OCCUPANCYNACANCY SENSORS <br />SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN <br />GRILLE. <br />B. CONTRACTOR SHALL VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT <br />LOCATIONS WITH ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. <br />PRIOR TO MAKING THE ACTUAL ELECTRICAL INSTALLATION, THIS CONTRACTOR SHALL <br />ADJUST RECEPTACLES, OUTLETS, OR CONNECTION LOCATIONS TO ACCOMMODATE <br />FURNITURE AND/OR EQUIPMENT. <br />9. ELECTRICAL AND TECHNOLOGY EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, <br />OPERATION OF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL <br />MOUNTING OF ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT, ON EQUIPMENT <br />SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE OTHER <br />CONTRACTOR. <br />10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL <br />OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE <br />EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR <br />SEALED INTO OPENINGS. <br />11. ALL WELDING SHALL BE ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS. <br />CONTRACTOR SHALL FURNISH TO THE ARCHITECT/ENGINEER CERTIFICATES QUALIFYING <br />EACH WELDER, PRIOR TO START OF WORK. THE ARCHITECT/ENGINEER RESERVES THE <br />RIGHT TO REQUIRE QUALIFYING DEMONSTRATION, AT THE CONTRACTOR'S EXPENSE, OF <br />ANY WELDERS ASSIGNED TO THE JOB. <br />12. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY <br />AUDIONISUAL, AND OTHER ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING <br />MOUNTED DEVICES, OTHER THAN SPRINKLERS. <br />13. ELECTRICAL IDENTIFICATION. REFER TO SPECIFICATION SECTION FOR COLOR/LABEL <br />REQUIREMENTS FOR CONDUIT, BOX, CABLEN/1RE, AND EQUIPMENT. <br />ELECTRICAL RENOVATION NOTES: <br />THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED <br />TO, LIGHTING, POWER, AND SYSTEMS. <br />1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD <br />SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND <br />REPORT ANY CONFLICTS BEFORE PROCEEDING. <br />2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. VERIFY EXISTING <br />CONDITIONS AND REPORT ANY CONFLICTS WITH NEW WORK BEFORE STARTING WORK. <br />3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR CABLE TRAY, BUSWAY AND CONDUITS <br />BEFORE FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING <br />FIELD CONDITIONS. <br />4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS/HER WORK <br />AND SHALL NOTIFY THE GENERAL CONTRACTOR PRIOR TO BIDDING IF OTHER UTILITIES ARE <br />REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF <br />WORK. <br />5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF <br />ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS. <br />CONTRACTORS SHALL NOTIFY THE GC OF AFFECTED AREAS PRIOR TO BIDDING. <br />6. GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS, <br />CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL <br />CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO <br />BIDDING. <br />7. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW <br />EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER <br />ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES <br />NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO <br />ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK. <br />�I,blc LAWRENCE <br />GROUP <br />St' Louis <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />(314)231-5700 <br />PROJECTTEAM: <br />GENERAL CONTRACTOR: <br />TBD <br />PROFESSIONAL ENGINEER: <br />NMEG <br />IMEG <br />7600 E Orchard Road, Suite 250-S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />MEG Project No.: 23000048.10 <br />PROFESSIONAL SEAL: <br />It. Do <br />opa <br />o� <br />'4 51988 <br />�sS�UNAL>� <br />05/24/2023 <br />PROJECTTITLE: <br />U <br />� <br />O <br />L.L <br />H <br />Z 0 <br />W ■ <br />� J <br />O _A <br />Of <br />d <br />(1W' <br />H <br />Z <br />Q <br />Z <br />W <br />H <br />J 06 U <br />L! <br />W <br />0 <br />O <br />U <br />L0 <br />M- <br />W <br />CO <br />J <br />0 <br />M <br />N <br />06 <br />W <br />N <br />TM1e Professional Architect's seal affixetl to this sheet <br />applies only to the materiel end Items shown on this <br />—1, All drawings i 11- b Ms or id prepared <br />y <br />exsibrl,g,,t, seal hM1ell not be rxsn newlytl prepared by <br />this architect, and Ihla architect expressly discbims any <br />and all responsibility for shM1 ns, platlrawirgs or <br />tlocumenis not exhibiting this <br />this seal. <br />This tl,M W end details on it are the We property of die <br />—hi." and may be need for this spectlic project only. <br />It shall not be band, copied or repmtluced, in whole or <br />pad, or for any other purpose or project wilhout the <br />written consent of the ..hit-. <br />No Description Date <br />SHEET TITLE'. <br />ELECTRICAL COVER <br />SHEET <br />PROJECT NUMBER: <br />SHEET NUMBER: <br />2021932.001 <br />omwn Rr <br />ARD <br />Issue Dale: <br />O <br />May 23, 2023 <br />