GENERAL NOTES (POWER): <br />A. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION INCLUDING SPECIFIC <br />LOCATIONS AND REQUIREMENTS FOR DEVICES. <br />B. DEVICES SHOWN IN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN. DEVICES SHOWN IN <br />HEAVY LINE WEIGHT ARE NEW. <br />STAIRCASE <br />C. REVIEW ENGINEERING DOCUMENTS IN CONJUNCTION WITH ARCHITECTURAL PLANS AND <br />COORDINATE WORK TO INCLUDE REQUIREMENTS OF BOTH DISCIPLINES. <br />D. THE INFORMATION ON THESE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING <br />PANEL PP1 TOILET <br />DRAWINGS AND FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS <br />104 <br />CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE <br />0 <br />PP1-22 24 <br />SITE, PRIOR TO BID, AND BECOME FAMILIAR WITH THE EXTENT OF THE WORK REQUIRED. <br />NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE THAT ARE <br />® EWH-1 <br />REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS. <br />PP1-1 <br />E. RECIRCUIT ALL EXISTING DEVICES, NOTED WITH A CIRCUIT DESIGNATION, TO NEW CIRCUIT <br />� <br />AS INDICATED. <br />PP1d <br />� <br />PP1-1 <br />EF-1O <br />KEYNOTES <br />1 PROVIDE CONNECTION TH MODULAR PARTITIONS. THE BRANCH CIRCUITS <br />OPEN <br />BE SIMULTANEOUSLY <br />SUPPLYING POWER TO THE PORTABLE PARTITIONS SHALL BE SIMULTANEOUSLY <br />SHALL <br />103 <br />DISCONNECTED AT THE ELECTRICAL PANELBOARD WHERE THE BRANCH CIRCUITS <br />1 PP1-3 <br />ORIGINATE PER N.E.C., ARTICLE 605 REQUIREMENTS. THE CIRCUITS SHALL BE DISCONNECT <br />BY BREAKER HANDLE TIES OR AS DIRECTED BY LOCAL JURISDICTION. VERIFY AND ENSURE <br />EXACT METHOD OF SIMULTANEOUSLY DISCONNECTING WITH LOCAL JURISDICTION FIELD <br />INSPECTOR PRIOR TO CONNECTION OF PORTABLE PARTITIONS. COORDINATE EXACT <br />qPPPi-12 <br />LOCATION OF SERVICE AND CONNECTIONS TO FURNITURE PANEL WITH PARTITION <br />INSTALLER AS REQUIRED. FINAL CONNECTION TO PARTITIONS SHALL BE BY THE <br />ELECTRICAL CONTRACTOR. ALL WIRING FROM ELECTRICAL PANEL TO POWER WHIP <br />CONNECTION SHALL BE #12 WIRING IN 3/4" CONDUIT. <br />2 MODULAR PARTITIONS TELEPHONE/DATA SERVICE POINTS. ELECTRICAL CONTRACTOR <br />SHALL INSTALL JUNCTION BOX AND CONDUIT WITH PULL WIRE FOR CABLING INSTALLATION. <br />ALL CABLING INSTALLATION AND TERMINATIONS SHALL BE BY TENANT COMMUNICATIONS <br />® <br />CONTRACTOR. REFER TO BUILDING SPECIFICATION NOTES FOR ADDITIONAL INFORMATION. <br />COORDINATE ALL REQUIREMENTS AND SERVICE POINTS WITH COMMUNICATIONS <br />CONTRACTOR PRIOR TO ROUGH -IN. <br />3 EF-#: 16W, 120V, 1 PH. THE FAN IS PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR, <br />WIRED BY ELECTRICAL CONTRACTOR. PROVIDE DISCONNECTING MEANS AS REQUIRED PER <br />N.E.C. EXHAUST FAN SHALL BE CONTROLLED BY LIGHT SWITCH SERVING THIS ROOM. <br />4 EWH-1 : 480OW, 24OV, 1PH. PROVIDE A LOCK OFF TYPE CIRCUIT BREAKER TO THE CIRCUIT <br />SERVING WATER HEATER. CONNECT AS REQUIRED AND COORDINATE EXACT LOCATION <br />AND REQUIREMENTS WITH PLUMBING CONTRACTOR PRIOR TO ROUGH -IN. CONNECT WITH <br />(2#10+410G)1"C. <br />�O <br />M1.J RECEP O <br />100 <br />D <br />WAITING I1 <br />1011 O <br />l <br />(Ar.') POWER AND SYSTEMS PLAN <br />NQ RT t� <br />LAWRENCE <br />GROUP <br />St. Louis <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />(314)231-5700 <br />PROJECTTEAM: <br />GENERAL CONTRACTOR: <br />TBD <br />PROFESSIONAL ENGINEER: <br /><>IMEG <br />IMEG <br />7600 E Orchard Road, Suite 250-S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />MEG Project No.: 23000048.10 <br />PROFESSIONAL SEAL: <br />It. Do <br />opa <br />o� <br />'4 51988 ,�yt <br />O �Vf3fERii� .iv <br />�sS�UNALBN�` <br />05/24/2023 <br />PROJECT TITLE: <br />rn <br />M <br />H <br />LU <br />M <br />w <br />w <br />U� <br />o <br />�O <br />z <br />= <br />w <br />w <br />0 <br />U <br />�m <br />Z <br />Q <br />Z <br />w <br />ZI_ <br />LLI <br />} <br />CO <br />H <br />Q <br />Q <br />U 06 <br />0 <br />w ��// <br />ry <br />M <br />M <br />CV <br />O = <br />N <br />TM1e Professional ArohRecf's seal affixetl fp this sheet <br />applies Dory to the materiel end Items shown on this <br />All drawings, intro <br />sheet. ohor—documents nt <br />e ibhh,, this seal shell not be considered prepared by <br />this architect, and this architect eVressly disclaims any <br />andall seprnsibilily for soph plers, drawirgs or <br />do oro s not exhibiting this seal. <br />This d,MN and details on R are the sole property of die <br />a hRect and may be used for this spectio project only. <br />It shall not be band, copied or reproduced, in whole or <br />pad, or for any ofher purpose or project wthoot the <br />written poneont of the arohnea. <br />No Description <br />Date <br />SHEET TITLE: <br />POWER AND <br />SYSTEMS PLAN <br />PROJECT NUMBER: <br />SHEET NUMBER: <br />2021932.001 <br />omwn"T <br />ARD <br />Issue Dale: <br />May 23, 2023 <br />