My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9808 3RD AVE SE 2024-11-07
>
Address Records
>
3RD AVE SE
>
9808
>
9808 3RD AVE SE 2024-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2024 8:49:40 AM
Creation date
7/31/2024 11:08:07 AM
Metadata
Fields
Template:
Address Document
Street Name
3RD AVE SE
Street Number
9808
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> • • <br /> Yu &TROCHALAKIS, PLLC <br /> Structural Engineers <br /> July 31,2023 <br /> Todd Pullman <br /> Everett Housing Authority <br /> RE: Douglas Grove Apartments <br /> 9803 3rd Avenue SE <br /> Everett,WA <br /> Dear Todd, <br /> Per your request,this letter addressed the reconstruction of one unit within a four-unit building that was <br /> damaged due to fire. The 2018 Washington State Existing Building Code is being used to establish the <br /> requirements for reconstruction. Section 405.2.1 states that repairs less than Substantial Structural Damage <br /> the damaged elements shall be permitted to be restored to their predamaged condition. The relevant section <br /> is included below: <br /> Section 405 Structural <br /> MI 405.1 General <br /> Structural re:eirs shall be in compliance with this section and raic 401 Z. <br /> [BSI 405.2 Repairs to Damaged Buildings <br /> r epa,rs to damaged buildings shalt comply with this section, <br /> [BSI 405.2.1 Repairs for Less Than Substantial Structural Damage <br /> Unless otherwise required by this section,for damage less than subnrantiof s ucturoi <br /> damage,the damaged elements shall be permitted to be restored to their predamage <br /> condition. <br /> [BS)405.2.1.1 Snow Damage <br /> Structural components whose damage was caused by or related to snow load <br /> effects shall be repaired,replaced or altered to satisfy the requirements of <br /> Section 1608 of the tmCrasst anc Bwidin;;Coca <br /> [BS)405.2.2 Disproportionate Earthquake Damage <br /> A building assigned to Seismic Design Category D,E or F that has sustained <br /> drsp�aPar,Cn�te rartirquake.damage shad be subject to the requirements for buildings <br /> with substarVe.`rrucrvr-si dnmsgr to vertical elements of the lateral force-resisting <br /> system. <br /> [BS)405.2.3 Substantial Structural Damage to Vertical Elements of <br /> the Lateral Force-Resisting System <br /> A building that has sustained substcndew sttuctura-da^:uge to the vertical elements of <br /> its lateral force-resisting system shall be evaluated in accordance with Y-.t: <br /> 4352 -'.,and either repaired in accordance with Section-035 2 3.2 or repaired and <br /> retrofitted in accordance with Sect a❑403 2 3.3,depending on the results of the <br /> evaluation. <br /> 13555 SE 36th Street,#310 INNOVATIVE DESIGN Phone 425-451-9049 <br /> Bellevue,WA 98006 Fax 425-451-8532 <br />
The URL can be used to link to this page
Your browser does not support the video tag.