My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2902 RUCKER AVE FAST SIGNS 2024-10-25
>
Address Records
>
RUCKER AVE
>
2902
>
FAST SIGNS
>
2902 RUCKER AVE FAST SIGNS 2024-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2024 11:37:05 AM
Creation date
7/31/2024 11:24:49 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2902
Tenant Name
FAST SIGNS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCRETE COMPRESSIVE STRENGTH TEST REPORT <br /> Report Number: M7231506.0003A a Terracon <br /> Service Date: 07/25/23 20225 Cedar Valley Rd Ste 110 <br /> Report Date: 08/24/23 Revision 1 - 28-day results Lynnwood, WA 98036-6365 <br /> Task: 425-742-9360 <br /> Client Project - M7231506 <br /> MVM CMD LLC 2902 Rucker ADA Ramp <br /> Attn: Michael Morgan 2902 Rucker Ave <br /> 2284 W Commodore Way Ste 220 Everett, WA <br /> Seattle, WA 98199-1468 <br /> Permit No.: B2305-077 <br /> Material Information Sample Information <br /> Specified Strength: 3,000 psi @ 28 days Sample Date: 07/25/23 Sample Time: 1330 <br /> Sampled By: Randal Dohrman <br /> Mix ID: 0160PG50 Weather Conditions: Partly cloudy <br /> Supplier: Smokey Point Concrete Accumulative Yards: 3 Batch Size (cy): 3 <br /> Batch Time: 1230 Plant: 603R Placement Method: Buggy <br /> Truck No.: 9176 Ticket No.: 310193 Water Added Before (gal): 0 <br /> Field Test Data Water Added After(gal): 0 <br /> Sample Location: ADA ramp slab <br /> Test Result Specification Placement Location: ADA ramp slab <br /> Slump (in): 5 Sample Description: 4-inch diameter cylinders <br /> Air Content(%): <br /> Concrete Temp. (F): 72 <br /> Ambient Temp. (F): 71 <br /> Plastic Unit Wt. (pcf): <br /> Yield (Cu.Yds.): <br /> Laboratory Test Data <br /> Age at Max Comp <br /> Set Spec Cyl. Avg Diam. Area Date Date Test Load Strength Frac Tested <br /> No. ID Cond. (in) (sq in) Received Tested (days) (lbs) (psi) Type By <br /> 1 1 Good 3.99 12.5 07/26/23 08/01/23 7 32,770 2,620 2 JBD <br /> 1 2 Good 3.98 12.44 07/26/23 08/22/23 28 61,560 4,950 2 KLR <br /> 1 3 Good 3.98 12.44 07/26/23 08/22/23 28 60,420 4,860 2 KLR <br /> 1 4 Good 4.00 12.57 07/26/23 08/22/23 28 62,660 4,990 5 KLR <br /> Average (28 days) 4,930 <br /> Initial Cure: Inside Final Cure: Moist Room <br /> Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit <br /> weight. <br /> Note: Reported air content does not include Aggregate Correction Factor(ACF). <br /> Samples Made By: Mayes/Terracon <br /> Services: Special Inspections/ Materials Testing <br /> Mayes/Terracon Rep.: Randal Dohrman <br /> Reported To: MVM CMD LLC <br /> Contractor: MVM CMD, LLC <br /> Report Distribution: <br /> (1)MVM CMD LLC,Michael Morgan (1)City of Everett WA,Permit Services Reviewed By: <br /> (1)Mayes Testing Engineers,Inc,Donna (1)Mayes Testing Engineers,Inc,Todd Wirtz Barry Tuttle <br /> Pollard Project Field Manager <br /> Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 <br /> The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be <br /> reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and <br /> are not necessarily indicative of the properties of other apparently similar or identical materials. <br /> CRoo01,3-31-22,Rev.7 Page 1 of 1 <br />