Laserfiche WebLink
L-Series Specifications <br />General <br />L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - <br />gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used <br />for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series <br />products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output <br />and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs <br />shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor <br />L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. <br />Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. <br />Strobe <br />The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe <br />shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible <br />signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and <br />associated lens/reflector system. <br />Horn Strobe Combination <br />The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective <br />service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act <br />requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist <br />of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a <br />temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe <br />models shall operate on a coded or non -coded power supply. <br />Synchronization Module <br />The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module <br />shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns <br />on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also <br />control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more <br />synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. <br />Standard Operating Temperature 32°F to 120°F (0°C to 49°C) <br />Humidity Range 10 to 93% non -condensing <br />Strobe Flash Rate 1 flash per second <br />Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' <br />Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) <br />Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) <br />Input Terminal Wire Gauge 12 to 18 AWG <br />Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) <br />Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) <br />(SBBCRL, SBBCWL) <br />Notes: <br />1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs <br />2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. <br />AVDS86800 <br />