<br />Onsite use and location of the modular building is
<br />the jurisdiction of the local building official. Site,
<br />grade and plot drainage plans are not reviewed by
<br />LNI.
<br />STATE OF WASHINGTON
<br />DEPT. OF LABOR AND INDUSTRIES
<br />SPECIALTY COMPLIANCE SERVICES DIVISION
<br />FACTORY ASSEMBLED STRUCTURES
<br />PLAN APPROVAL #18FBS2300183
<br />SUBJECT TO FIELD INSPECTION.
<br />OVERSIGHTS, OR VIOLATION OF RCW/WAC's
<br />OR WA STATE CODES ARE NOT APPROVED
<br />12/15/2023
<br />Michael Luke DATE:
<br />EXPIRATION DATE: 03/14/2024
<br />2nNP)30 Ne fflansi�n AWQI\n�, EWQ�n�_FRI'�n449 WeA gnL0))201
<br />Code COMPH81mce
<br />Applicable Codes: ..........................
<br />WASHINGTON:
<br />2018 International Building Code with WA Amendments
<br />2018 International Mechanical Code with WA Amendments
<br />2018 Uniform Plumbing Code by IAPMO with WA Amendments
<br />2020 National Electrical Code with WA Amendments
<br />2018 Washington State Energy Code
<br />2009 ICC A117.1 Accessibility Standard
<br />Type of Construction: ......................
<br />VB
<br />Description: ......................................
<br />Park Restroom
<br />Occupancy: ....................................
<br />B
<br />Occupancy Load: ............................
<br />2
<br />Floor Area: ......................................
<br />267 - square feet
<br />Gross Wall Area: ...............................
<br />530 - square feet
<br />Climate Zone: ....................................
<br />4c
<br />PRC Project Number: .....................
<br />11543A
<br />Certified Manufacturer:
<br />BLAZER INDUSTRIES, Inc.
<br />PO Box 489
<br />Aumsville, OR 97325
<br />Contact: Jamie Holmes
<br />Phone: (503) 749-1900
<br />Also see the NLEA (notice to local enforcement agency) form E-mail:Fax(503) blaze 69
<br />in
<br />attached to this plan set. NLEA items may require review, E-m]dmeS@blaZerind.COm
<br />p p p p approval and/or inspection by local authority having
<br />jurisdiction TYPICAL ALL SITE INSTALLED ITEMS
<br />• Foundation plan review and inspection.
<br />• An accessible route shall be provided to the building area as required in IBC section 1104.
<br />PTOPCIR 4mbTuOU'alm
<br />Designer / Dealer:
<br />PUBLIC RESTROOM COMPANY
<br />2587 Business Parkway
<br />Minden, NV 89423
<br />Contact: Chad Kaufman
<br />Phone:(888) 888-2060
<br />Fax: (888) 888-1448
<br />Email: Chad@publicrestroomcompany.com
<br />www.publicrestroomcompany.com
<br />Building Engineer:
<br />Rock Shetler, P.E.
<br />Blazer Industries, Inc.
<br />PO Box 489
<br />Aumsville, OR 97325
<br />Phone: (503) 749-1900
<br />E-mail: rock@blazerind.com
<br />Project Owner:
<br />City of Everett, WA
<br />802 E Mukilteo Blvd.
<br />Contact: Joan Olsen
<br />Phone: (425) 754-0345
<br />Email: jolsen@everettwa.gov
<br />• Electrical connection to service. \
<br />This is anon-heatedI����JJJu
<br />n
<br />I�
<br />n
<br />j�
<br />HoiRes
<br />• On -site electrical service grounding, electrode system and bonding. building. Local
<br />uILLL�JJJ
<br />u
<br />approval of
<br />• Required arc flash labeling per NEC 110.16 weatherization CONTACT THE LOCAL AUTHORITY HAVING JURISDICTION FOR ONSITE PERMITTING AND INSPECTION REQUIREMENTS.
<br />• Available fault current field markings per NEC 110.24. procedures as/if
<br />required.
<br />The structural design details herein are specific to the building size and module configuration shown on the Floor plan of these drawings.
<br />• Plumbing connection to service, and completion of underfloor plumbing.
<br />This building will be sited a minimum of 10 feet from all property lines and 10 feet from any assumed property lines between existing structures on site.
<br />• Installation of heat tape, when required.
<br />•
<br />Thermal envelope requirements not applicable due to the building being unconditioned.
<br />• On -site testing of tempered water delivered to public lavatories. Per UPC 407.3 tempered water shall be a maximum 120°F.
<br />•
<br />ADA Accessibility to this structure shall be in conformance with local code including all pathways, ramps and paths of travel from parking to building
<br />• Water heater pressure relief valve and/or drain pan disposal terminates at building exterior or an approved location.
<br />•
<br />Soil bearing requirement is 1500 psf, subGRADE Compaction at 90%.
<br />• On site Special Inspection - Concrete Construction - Post installed anchors at slab to foundation.
<br />Building plumbing system is based upon full Flow existing water service. Loss of required flow rate of 10 gpm or pressure below 35 psi may necessitate an
<br />• On site door closing speed and opening force adjustments in accordance with ICC A117.1-2009 by others.
<br />intermediate well tank and check valve in line.
<br />• Fire extinguisher(s) installed on site when required.
<br />Project close out documentation including, but not limited to, applicable calculations, energy compliance reports, fenestration NFRC rating certificates and 0
<br />• Site completion or installation of siding, roofing, exterior/interior trim, floor covering and any electrical, plumbing or
<br />& M manuals is required to be delivered to the building owner within 90 days of their receipt of the certificate of occupancy.
<br />mechanical crossover connections as they pertain to mod connections. .
<br />Site installation details are noted on sheets A-4, A-5 and S-1 for structural connections, A-2 for weatherization finish, P-1 for Plumbing connections and E-1
<br />• Site installed gutters & downspouts or roof drains as applicable.
<br />for electrical connections. SITE INSTALLATION PROCEDURE INCLUDES BUT NOT LIMITED TO: Service Hookups (Electrical & Plumbing connections),
<br />Installation of Ridgecap material Installation of Vol trim interior and Exterior, Install backer rod and caulk mod line - walls, Install SL-1 Self -leveling
<br />• Per WAC 296-15OF: The on -site installation of interior equipment and appliances associated with the modular unit shall be
<br />caulk (use on floor joint)Grout Tile at mod line connection, Finish paint modline connection. Installation of Modline & Capbeam Mod connections.
<br />completed under permit and inspection with the local building department.
<br />STATE OF WASHINGTON
<br />DEPT. OF LABOR AND INDUSTRIES
<br />FACTORY ASSEMBLED STRUCTURES
<br />ELECTRICAL PLAN REVIEW
<br />PLAN APPROVAL #18FBS2300183
<br />BY: Jason Summers DATE: 11/2l/2023
<br />EXPIRATION DATE: See main plan exammer stamp
<br />SUBJECT TO CODE AND FIELD INSPECTION
<br />hmdu Ro Wwhmo
<br />T-1 Title Sheet.
<br />AC Accessibility Compliance.
<br />A-1 Floor Plan, Structural Design, Door Schedule.
<br />A-1.1 Sections, Roof Framing Plan.
<br />A-2 Exterior Elevations, Exterior Finish Schedule.
<br />A-3 Interior Elevations, Interior Finish & Accessories Schedules.
<br />A-4 Details, Fastening Schedule.
<br />A-5 Cap Beam Plan & Details.
<br />P-1 Plumbing Plan & Information.
<br />E-1 Electrical Plan & Information.
<br />S-1 Slab Plan & Foundation Plan.
<br />Foundation plans and details are not reviewed by L&I, except for the
<br />reasonability of the design to support the modular building. Approval and
<br />inspection of the foundation system is the jurisdiction of the local building
<br />offi 1. This is typical for all foundation relaletl sheets, details and
<br />engineering contained w 1hid this plan at.
<br />DGo sogi Im L a 85, d s
<br />Roof ............................. 25 psf (Snow)
<br />Wind ............................ 115 mph Exposure "C" (V)
<br />Floor ............................. 50 psf, Slab -On -Grade
<br />Seismic ........................ SITE CLASS D, SDs = 0.996, SD1 = 0.547
<br />Risk Category II
<br />Minimum allowable soil pressure 1,500 psf
<br />11 /07/2023
<br />'_TBlEsweBE
<br />a.o. soxase mazeri�d.com
<br />■■ ens of^ey st. • msv�ue, oB e�a2s-case
<br />COPYRIGHT HIS BLAZER INDUSTRIES, INC. AND PUBLIC RESTROOM
<br />FBLAZER
<br />COMPANY. THIS MATERIAL IS THE EXCLUSIVE PROPERTY BLAZER
<br />AND PUBLIC RESTROOM COMPANY AND SHALL NOT
<br />REPRODUCED, USED, OR DISCLOSED TO OTHERS EXCEPT AS
<br />AUTHORIZED BY THE WRITTEN PERMISSION OF BLAZER INDUSTRIES
<br />OR PUBLIC RESTROOM COMPANY.
<br />I
<br />PUBLICINDUSTRIES,INC.
<br />WMOOM
<br />IkCOMPANY
<br />Building Better Places To Go.
<br />Ph : 888-888-20601 Fax: BBB-888-1448
<br />PROJECT NAME &LOCATION:
<br />EMB
<br />A
<br />Everett, WA
<br />SHEET TITLE:
<br />TITLE SHEET
<br />^ppr°°ed r°r °°^sc
<br />eb Ne
<br />zo38t
<br />File Copy:
<br />T 1
<br />LL�
<br />Drawn B : NJP
<br />y
<br />REVISION
<br />BY
<br />DATE
<br />REV#
<br />REVISION
<br />F3Y
<br />Issue Data 10-18-23
<br />Page 5 of 118 Expires 03/14/2024