R I GTON Abbreviations <br /> AIR QUALITY SERVICES <br /> AC or ACU Air Conditioning Unit EAT Entering Air Temperature AP Pressure Drop. <br /> AHU Air Handling Unit EF Exhaust Fan PH Phase <br /> Ak The area of an opening in sq./ft. EG/ED Exhaust Grille/Diffuser PSI Pounds per Square Inch <br /> ATM Atmosphere EMS Energy Management System RA Return Air <br /> AVG Average ERU Energy Recovery Unit RAT Return Air Temperature <br /> BHP Brake Horsepower FHT Fume Hood Test RF Return Fan <br /> CAV Constant Air Volume FPB Fan Powered Box RH Relative Humidity <br /> CBV Cal. Balance Valve FPM Feet per Minute RHC Reheat Coil <br /> CC Cooling Coil FT Foot, Feet RPM Revolutions per Minute <br /> CD Ceiling Diffuser GPM Gallons per Minute RTU Roof Top Unit <br /> CFM Cubic Feet per Minute HC Heating Coil SA Supply Air <br /> CH Chiller TDH Total Dynamic Head-Pump SAT Supply Air Temperature <br /> CHWS Chilled Water Supply HEPA High Efficiency Particulate Arrentance S.F.Service Factor <br /> CHWR Chilled Water Return HP Horsepower SF Smoke/Fire Damper <br /> CP Circulating Pump HVAC Heating Ventilation and AC SWG Sidewall Grille <br /> CD/CR Ceiling Diffuser/Register HWS Heating Water Supply TAB Test,Adjust&Balance <br /> CRAC Computer Room AC HWR Heating Water Return TEMP Temperature <br /> CRU Computer Room Unit HX Heat Exchanger TON 12,000 BTUH(Cooling <br /> CT Cooling Tower HZ Hertz,cycle/second of current TSTAT Thermostat(T) <br /> CU Condenser Unit in.w.g.inches of water gauge TSP Total Static Pressure <br /> CUH Cabinet Unit Heater K-factor Correction factor to the free area UH Unit Heater <br /> needed to calculate CFM <br /> CWS Condenser Water Supply KW Kilowatts V Volt—Either AC or DC <br /> CWR Condenser Water Return LAT Leaving Air Temperature VAV Variable Air Volume box <br /> D Discharge LWT Leaving Water Temperature VD Volume Damper <br /> DAT Discharge Air Temperature MAU Make-up Air Handling Unit VEL Velocity(usually in FPM) <br /> DB Dry Bulb MBH 1,000 BTUH VFD Variable Frequency Drive <br /> DDC Direct Digital Controls NT Not Tested VVT Variable Volume Terminal <br /> DP Differential Pressure OSA Outside Air W.G.Water Gauge <br /> DNA Data not available or given OBD Opposed Blade Damper WB Wet Bulb <br /> DNV Data Not Visible OD Outside Diameter <br /> 1) TAB—Test the quantitative performance of a system then regulate it to a specific rate and to the proportion the <br /> flow according to the design <br /> 2) Flowhood—Instrument used by a Balancer to capture air and measures and reports in CFM <br /> 3) Total Static Pressure-Difference in pressure from the inlet to the discharge of a fan added together <br /> 4) Economizer—Components and controls that allow an air handler to effectively use outside air instead of <br /> mechanical cooling to save energy and provide building pressurization <br /> 5) Total Dynamic Head-The difference between the pressure of a fluid entering a pump vs exiting added together <br /> 6) Design Tolerance—Specified by the designer or+/-10% <br /> 7) Ratio of Tolerance-Used to verify that terminals and/or the system are within Design Tolerance;Example 90%- <br /> 110%of design if design was 250 then.90/1.10=1.22 and flow between 275CFM-225CFM would be acceptable <br />