Laserfiche WebLink
• 2615 BROADWAY • <br /> EVERETT, WA 98201 <br /> Rainbow Federal, Inc. conducted a site visit where we took measurements of the building, noted wall heights, lineal <br /> feet of curbs, number of penetrations and any irregular conditions. He reported that the structure was sound and <br /> he did not find any areas that were"soft" or that would need to be replaced. <br /> A core cut sample was taken from the roof to determine the existing roof system. There is one (1)existing Built-Up <br /> asphalt roof system,'A" perlite cover board,3"of insulation and a rosin paper separator sheet all over a plywood <br /> roof deck. The entire existing roof system measures 4"thick. <br /> /11 <br /> t � 01 <br /> y'. <br /> 'y <br /> r <br /> He noted any non-typical conditions that would need specific detailing,which are as follows: <br /> • Steel structures that the larger units sit on. Some have less clearance above the existing roof than others. <br /> They all have posts that penetrate the roofing that will need to be roofed in watertight. <br /> • <br /> .` z,•.. - e""-'� -- -_.i _. • <br /> -741 <br /> _ <br /> • A portion of the front wall has asphalt shingles installed. Where the new TPO membrane meets this <br /> condition,it will need to be tied in correctly to make it watertight. <br /> •� fly _ <br /> l I t <br />