My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
216 73RD ST SW 2023 Plans 2024-08-19
>
Address Records
>
73RD ST SW
>
216
>
Plans
>
216 73RD ST SW 2023 Plans 2024-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2024 2:46:37 PM
Creation date
8/19/2024 2:46:32 PM
Metadata
Fields
Template:
Address Document
Street Name
73RD ST SW
Street Number
216
Permit
B2307-045
Year
2023
Notes
INSTALL (7) HELICAL TO STABALIZE EXISTING FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> 73RD ST SW '• <br /> PILE SPACING&LOAD REQUIREMENTS TABLE <br /> MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips <br /> PILE is PILE TYPE PILES END OFFSET ALLOWABLE LOADING BIM PILES MIN VERTICAL CAPACITY LOCATION <br /> (MIN ULTIMATE CAPACITY) <br /> 1,7 7'-0" 11.0 k/PILE 22.0 k/PILE EXTERIOR <br /> 2-5 PER PLAN 16.0 k/PILE 32.0 k/PILE CHIMNEY <br /> HELICAL PER PLAN <br /> PROPERTY LINE 3-4 PER PLAN 18.0 k/PILE 36.0 k/PILE CHIMNEY <br /> -------"---"-"---"-"-"---- ---"-"---"-----------�.-.-.--� 6 <br /> NOTES: <br /> 7'-0" 7.0 k/PILE 14.0 k/PILE INTERIOR <br /> 75'-0"' <br /> 4ANt <br /> a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE <br /> I <br /> MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING W <br /> CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM Q . 6 <br /> INSTALLATION TORQUE RATING OF 8,300FT"LBS FOR A 2-718 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL i..- a <br /> THICKNESS PER ESR-3750. z o <br /> 30' ¢ b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" I- w m <br /> 0I 6 y I TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. z <br /> m I• w , c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. 0 <br /> ti rr c0i I U. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART W <br /> <; O< M I OF THE ASSEMBLY. Z W <br /> z I e. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. O Z z <br /> rn I w <br /> I I J <br /> i I1 I �4' 23'-6" 'I' 1 <br /> t FOUNDATION NOTES ,/�� <br /> 32'-� " 1 1-011 1. VERIFY ALL DIMENSIONS ON SITE. '� <br /> r ` 1 <br /> 2.• <br /> FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. <br /> 2 I 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: 1141111,1 <br /> I 4)-3 <br /> I <br /> HELICAL PILE..........115D-1.1 <br /> .. - I 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED JULY 13TH,2023.FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND REQUIREMENTS. <br /> 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED APRIL 17TH.2023.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND <br /> 04 I ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. <br /> I 6. MINIMUM PILE DIAMETER SHALL BE 2-718'. <br /> uO o 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH±0'-6'TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED <br /> E / �, <br /> N L'RESIDENC5 73RD ST SW (E)CHIMNEY (E)GARAGE I 0&., DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED ON LEVEL SURVEY. <br /> E!ERETT.WA 98203 N I t 3 8. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8"THICK MINIMUM WITH T-8"HEIGHT(MEASURED FROM <br /> 7. ¢k BIFTG TOT/CONC)MINIMUM. <br /> -- I 0.6 I w o Ill <br /> 8. PARCEL AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,')APPROXIMATED PER SNOHOMISH COUNTY NAP.NOT TO BE USED FOR LEGAL <br /> l I ,y Z N j PURPOSES. <br /> v 0 • I> w 10.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. <br /> 5 •0 <br /> I w 11.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5-0"(UNO PER GEOTECHNK;AL REPORT). <br /> O <br /> } L_ I a HELICAL PILE REFUSAL CRITERIA: <br /> 1-5'-0',�' 56'-0" 7� At' I TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH 216 73RD ST SW <br /> I I A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. EVERETT <br /> I I <br /> (E)DECK WA 96203 <br /> I I i_ __..__ '.-- - S230503-1XR <br /> C I I Back JT <br /> ,, <br /> E N I 4 Decking • <br /> 0 I "'t Slab Walkway Slab Walkway <br /> -6 I I } 12' 7 •43' Access MRT <br /> `-y' I I ' 1 4 11,. r r B -I -1,4 07/13/2023 <br /> 0 I I o I <br /> E w O I I N 6C 7-0PAC MAX <br /> 0 co <br /> I b SITE PLAN LEGEND I '_, Garage -2 1`4 1.2 1/4 ,„,.1 <br /> -3/0ro <br /> ' Cr 0.3 i I I I Crac V,4 5 A, LOCATEsPILE UNDER Ij' <br /> EXISTING RESIDENCE STRUCTURE m 4 a 1BCHIMNEY GAT -1/4 - <br /> d I x ° CHIMNEY: TRIP FTG H <br /> n0 W I PARCEL NO. EXISTING ADJACENT STRUCTURE 3 CORNER N <br /> cr .0 J I 00453200001100 I 3 • <br /> �=Existing=3"Helical <br /> Crack In Foundation <br /> CL Q. _� LEGAL DESCRIPTION , AREA OF PROPOSED WORK I -t ti4 2 .1 •4�� -y, <br /> d - V I GARDNER MANOR BLK 000 I 12' •i,1.7 i 00 <br /> Q Z \ I D-DO-LOT 11 * PROPERTY LINE I LOCATE PILES Power 1 Crack 23S <br /> 7 <br /> Z <br /> N I OWNER NAME&ADDRESS WITHIN 2'0"OF LOCATE PILE <br /> y\ JAMES OLIVIA - APPROXIMATE DIMENSION I CHIMNEY SIDES WITHIN 3'-0" <br /> E a I 216 73RD ST SW I <br /> pE 1 I EVERETT.WA 98203 4). HELICAL PILE I FROM CORNER <br /> C� <br /> o \ I I R&R LEVEL SURVEY <br /> 8 LN I I See Structural Calculation Package for Additional Requirements <br /> gI 75,-0"* <br /> z PROPERTY LINE Q N <br /> d cr) <br /> W <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN F= <br /> Cn <br />