2118 JEFFERSON PL 2023 Plans 2024-08-19
>
Address Records
>
JEFFERSON PL
>
2118
>
Plans
>
2118 JEFFERSON PL 2023 Plans 2024-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2024 2:56:13 PM
Creation date
8/19/2024 2:56:08 PM
Metadata
Fields
Template:
Address Document
Street Name
JEFFERSON PL
Street Number
2118
Permit
B2307-071
Year
2023
Notes
INSTALL (9) HELICAL PILES TO STABILIZE EXIST SFR FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> a <br /> PILE SPACING&LOAD REQUIREMENTS TABLE <br /> JEFFERSON PL MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips I PROOF TESTING LOAD,kips <br /> PILE#PILE TYPE 200%MIN VERTICAL CAPACITY LOCATION <br /> r_._._._._' PROPERTYLINE MINN PILES END OFFSET ALLOWABLE LOADING ) !? , <br /> (MIN ULTIMATE CAPACITY <br /> I 82'-0"• �• 1-2,5 8'-0" 5.0 k/PILE 10.0 k/PILE GARAGE• <br /> c• f°; <br /> I •� 3 4 HELICAL 8 0 PER PLAN 7.0 k/PILE 14.0 k/PILE GARAGE roNa- '• <br /> j I 6-7 7'-0" 11.0 k/PILE 22.0 k/PILE EXTERIOR <br /> 8-9 8'-0" 10.0 k/PILE 20.0 k/PILE GARAGE <br /> I j NOTES: <br /> j a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE <br /> v MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> to I EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM <br /> INSTALLATION TORQUE RATING OF 8.300FT'LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL <br /> I <br /> THICKNESS PER ESR-3750. <br /> a a I b. FOR HELICAL PILES.PER IDEAL GROUP DWG NO.:278TFG.THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" <br /> I TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. <br /> C. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING.INC.. IN ACCORDANCE WITH ESR-3750. <br /> --- -16'O" _ I A A. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART Lll <br /> j t-- y I OF THE ASSEMBLY. a <br /> } <br /> 2H O' • `J 3 w I e. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. <br /> 16'0" I a< j -41161t1• FOUNDATION NOTES I- W N ❑Q <br /> j I4) 1. VERIFY ALL DIMENSIONS ON SITE. !SI tt <br /> j2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. �\.7J/ W z <br /> 14.-0"�'r 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: L z Z <br /> I (E)CHIMNEY L_�� i HELICAL PILE.................................1/SD-1.1 O Q <br /> HELICAL PILE W/CHANNEL........_215D-1.1 <br /> I 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED AUGUST 29TH,2023,FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND REQUIREMENTS. <br /> A RESIDENCE I 5, LEVEL SURVEY PER R&R REPAIR PLAN DATED AUGUST 25TH,2023.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND <br /> I 2118 JEFFERSON PL <br /> EVERETT,WA 98203 ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. <br /> i 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8'. '%. <br /> j9 j I 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH t 0'-6"TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED ♦� <br /> Oi I DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED ON LEVEL SURVEY. '�^ <br /> (E)GARAGE j 8. IF REQUIRED,ALL SUPPLEMENTAL CHANNELS TO SPAN FROM PILE TO PILE AND EXTEND MIN 6"PAST SUPPORTING PILE EA END. ` <br /> •8 •1 9. IF REQUIRED,ALL SUPPLEMENTAL CHANNELS TO BE ANCHORED TO THE FOUNDATION WITH 5l8"DIAM,SIMPSON TITEN HD SCREW ANCHORS(OR <br /> �� I APPROVED EQUIVALENT)AT A MAXIMUM SPACING 12"0C WI MIN 4"EMBED.ANCHORS TO BE CENTERED ON OR INSTALLED ABOVE THE CENTER LINE OF �' <br /> I NMI 44'0° •� 6 11 :I: <br /> THE CHANNEL. <br /> 10.FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8'THICK MINIMUM WITH 2'-8"HEIGHT(MEASURED <br /> 11111111 •I 2 I FROMC BL M T/ C) EDB, <br /> 5 7 11.PARCEL DIMENSIONS PROVIDED BY CITY OF SEATTLE.NOT TO SCALE.PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,') <br /> �_ _ 5'-O" APPROXIMATED PER SNOHOMISH COUNTY iMAP AND SEATTLE DEPARTMENT OF CONSTRUCTION AND INSPECTIONS GIS MAPPING TOOLS.NOT TO BE <br /> jI USED FOR LEGAL PURPOSES. <br /> I12.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. <br /> I 13.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"(UNO PER GEOTECHNICAL REPORT). <br /> I IIv <br /> m, I HELICAL PILE REFUSAL CRITERIA: <br /> z I P' - TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH <br /> --1. - '44f I a A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. <br /> MI Ia <br /> I 2118 JEFFERSON PL <br /> I I '.....\............ EVERETT <br /> I WA 98203 <br /> j (E)RETAINING WALL I <br /> I <br /> S230503-2XR <br /> j I t <br /> MAX V <br /> I I LOCATE PILE C6 8.2OCHANNEL LOCATE PILE JT <br /> j WITHIN 3'-0" WITHIN 3.-0" <br /> I FROM CORNERtib. 4 FROM CORNER M RT <br /> cs) <br /> c I SITE PLAN LEGEND I co I <br /> ' 08129/2023 <br /> 8-0"OC MAX W/C6x82 CHANNE s TTo-S Ira <br /> I I 1 EXISTING RESIDENCE STRUCTURE } (, I <br /> I CR T-0"OCM- ,. <br /> I EXISTING ADJACENT STRUCTURE (3)PILES @ 8'-0"• MAX • c a -MOW'W' Basement <br /> " <br /> j ___ W C6x8.2 CHA EL Y Yo <br /> I I <br /> j AREA OF PROPOSED WORK ,,& <br /> PARCEL NO. I PROPERTY LINE - " "'` p <br /> I 00512300000202 <br /> LEGAL DESCRIPTION - APPROXIMATE DIMENSION 6' <br /> j MAYNARDS PLAT BLK 000 D-02-W j <br /> 30FT LOT 2&E SOFT LOT 3 ¢ HELICAL PILE <br /> I <br /> ® '-�°""�'"" <br /> I OWNER NAME&ADDRESS N <br /> REITZ SUSAN&DENNIS I ® C6x8.2 CHANNEL o.3-Helical Pd. <br /> 2118 JEFFERSON PL .Existingc.a. Founneuon <br /> j <br /> t..M Pad <br /> EVERETT.WA 98203 Br.... <br /> SUM I I M <br /> Sm WM 6,7 <br /> Fo" algn Food g 1T <br /> jJOAN spaces a"0.0 <br /> _......_._._._._•_•_•_ _ _ _ _ _ -----...-..-.---.- <br /> PROPERTY B2 8 j R&R LEVEL SURVEY <br /> 1 • LINE '-'-•-•-•_ ._._._,_•_•_� See Structural Calculation Package for Additional Requirements Z <br /> a fV <br /> O_ (n <br /> LLJ <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN I-- <br />