PLUMBING FIXTURE AND DRAIN ROUGH-IN SCHEDULE APPROVED PIPE MATERIALS FOR DRAIN,WASTE,VENT PIPE AND FITTINGS Z
<br /> MARK FIXTURE TYPE WASTE(IN) VENT(IN) CW(IN) NW(IN) NOTES UNDERGROUND DRAIN, ABOVEGROUND DRAIN, BUILDING SEWER PIPE AND
<br /> WC-A WATER CLOSET-ADA"EXISTING TO REMAIN" 4" 2" 1/2" - - MATERIAL WASTE,VENT PIPE AND WASTE,VENT PIPE AND FITTINGS REFERENCED STANDARD(S)PIPE REFERENCED STANDARD(S)FITTINGS 1111,
<br /> FITTINGS FITTINGS
<br /> LV-A LAVATORY-ADA"EXISTING TO REMAIN 1-1/2" 1-1/2" 1/2" 1/2" - ABS(Schedule 40) X X X ASTM D2661,ASTM D2680 ASTM D2661,ASTM D2680 �mom
<br /> KS KITCHEN SINK"EXISTING TO REMAIN" 2° 2" 1/2" 1/2" Copper and Copper Alloys(Type ASTM B43,ASTM B75,ASTM B251,ASTM
<br /> DF DRINKING FOUNTAIN"EXISTING TO REMAIN" 1-1/4" 1-1/4" 1/2" - - DWV) W
<br /> B302,ASTM B306
<br /> HS HAND SINK 1-112" 1-1/2" 1/2" 1/2" - Galvanized Malleable Iron - X - - ASME B16.3 �
<br /> LS LAB SINK 1-112" 1-1/2" 1/2" 1/2" PVC(Schedule 40) X X X ASTM D1785,ASTM D2665,ASTM F794 ASTM D2665,ASTM F794,ASTM F1866
<br /> E-1 OWNER FURNISHED-MODEL TRIMMER 1-1/2" 1-1/2" 1/4" - NOTE:
<br /> SOLVENT CEMENT JOINTS TO BE IN ACCORDANCE WITH SECTION 705.5.2 OF THE SEATTLE PLUMBING CODE(SPC)AND ASTM F656 FOR PRIMER AND ASTM D2564 FOR SOLVENT CEMENTS.TYPICAL
<br /> E-2 OWNER FURNISHED-AUTOCLAVE 1-1/2" 1-1/2" 1/4"
<br /> E-3 OWNER FURNISHED-ULTRASONIC CLEANER 1-1/2" 1-1/2" 1/4" O
<br /> FD FLOOR DRAIN 2" 2^ - - - PIPE MATERIALS FOR BUILDING SUPPLY AND WATER DISTRIBUTION PIPING AND FITTINGS
<br /> FCO FLOOR CLEANOUT NOTE 4 - - - - MATERIAL BUILDING DISTRIBUTION PIPE WATER DISTRIBUTION PIPE REFERENCED STANDARD(S) REFERENCED STANDARD(S)FITTINGS
<br /> AND FITTINGS AND FITTINGS PIPE
<br /> VTR VENT THRU ROOF - - - - 5 ASTM B42,ASTM B43,ASTM
<br /> GENERAL NOTES Copper and Copper Alloys X X B75,ASTM B86,ASTM B135, ASME B16.15,ASME B16.18,ASME B16.22,
<br /> PIPE SIZES LISTED MAY BE DIFFERENT THAN THE ACTUAL FIXTURE CONNECTION.PROVIDE BRANCH PIPE OF LISTED SIZE AND PIPE FITTINGS AND ASTM 8251,ASTM B302,ASTM ASME B16.26,ASME B16.51
<br /> A OFFSETS AS REQUIRED FOR COMPLETE INSTALLATION B447
<br /> B PROVIDE FINAL CONNECTIONS TO ALL FIXTURES ASTM F876,ASTM F877,CSA ASSE 1061,ASTM F877,ASTM F1807,
<br /> PEX X X B137.5,AWWA C904 ASTM F1960,ASTM F1961,ASTM F2080,
<br /> C PROVIDE WALL CLEANOUTS FOR ALL SINKS AND WATER CLOSETS ASTM F2159,ASTM F2735,CSA B137.5
<br /> NOTES PVC X - ASTM D1765,ASTM D2241, ASTM D2464,ASTM D2466,ASTM D2467,
<br /> 1
<br /> ADA COMPLIANT WHERE INDICATED ON THE ARCHITECTURAL DRAWINGS.MOUNTING HEIGHT AS INDICATED ON ARCHITECTURAL DRAWINGS. AWWA C900 ASTM F1970
<br /> 2 PROVIDE TRAP PRIMER ASSEMBLY WITH NUMBER OF PORTS REQUIRED TO SERVE ADJACENT DRAINS.PROVIDE WITH SHUTOFF VALVE. WATER HEATER SCHEDULE
<br /> MANUFACTURER/ GALLONS RECOVERY WATER DIMENSION DxH OPERATING
<br /> 3 CW CONNECTION VIA TRAP PRIMER. MARK AREA SERVED MODEL NO. (GAL) BTUH V/PH. (GAL) RUNOUT(IN) (INxIN) WEIGHT(LBS) NOTES
<br /> 4 CLEANOUTS ARE TO BE INSTALLED EVERY 100 FEET. 27-3/4"x 55-1/2"x
<br /> 5 SIZE AS NOTED ON DRAWINGS.WHERE APPLICABLE,VENT SIZE SHALL BE AS NOTED ON THE DRAWING,1-1/2°,HALF SIZE OF WASTE OR WHICHEVER WH-1 HS&LS AO SMITH 60 6,000 WATTS 208/3 154 DIA 960 SET AT 140 DEG F CD V\
<br /> IS LARGER. NOTES: HEATER ELEMENTS ARE SIMULTANEOUS 31620 23rd Ave S
<br /> WATER AND WASTE SYSTEMS LOAD CALCULATIONS CIRCULATION PUMP SCHEDULE Federal Way,WA 98003
<br /> Linda@Burman.Design
<br /> WATER SOURCE TOTAL WASTE DRAINGE UNITS -
<br /> 253.508.2658
<br /> KIND OF FIXTURE NUMBER OF FIXTURES HWFUS TOTAL DRAINAGE UNITS DFUS MANUFACTURE PUMP MOTOR
<br /> FIXTURE UNITS WFUS PER FIXTURE MARK LOCATION SYSTEM SERVED R/MODEL NO. NOTES
<br /> HS 5 2 10 7.5 2 10 --- - TYPE FLOW(GPM) HEAD(FT) HP/W V/PH
<br /> LS 3 2 6 4.5 2 6 WATER BELL& DOMESTIC CONTROL PUMP W/
<br /> CP HEATER WH-1 GOSSETT CIRCULATOR 5 15 116 115/1 AQUASTATSET FOR 125
<br /> E-1 1 1 1 - 2 2 (ADJUSTABLE)
<br /> E-2 1 1 1 - 2 2 NOTES: CO
<br /> E-3 1 1 1 - 2 2 1-PROVIDE WITH BRONZE BODY CONSTRUCTION
<br /> N
<br /> c0
<br /> CD
<br /> TOTAL 19 12 22 DOMESTIC WATER EXPANSION TANK SCHEDULE Q
<br /> WATER PIPE SIZE(IN) 1" PRESSURE AVAILABLE MINIMUM ALLOWABLE MAXIMUM HEIGHT PHYSICAL
<br /> • SYSTEM MANUFACTURER/ TANK VOLUME ACCEPTANCE SYSTEM CONN. __ISUPPLY LINE WATER PIPE LENGTH MARK LOCATION SIZE(DIAxL) WEIGHT(LBS) NOTES
<br /> SIZING (FT) 100' 65 25 15 SERVED MODEL NO. (GAL) FACTOR (IN) (INxIN) WHEN FULL < u
<br /> TOTAL WSFU 31 FRICTION LOSS PER FOOT 33.55 PSI ET JANITOR-119 WH-1 AMTROLST-12C 6.4 0.5 3/4" 12"DIA x 18 81.3 1 Z CC
<br /> Lu
<br /> MAXIMUM LOADING OF WATER PIPE BASED ON 33.55 PSI DROP OVER 100 FEET AND MAX 8 FPS NOTE:EXPANSION TANK SHALL BE DELIVERED TO THE SITE PRE-CHARGED TO OPERATING PRESSURE.CONTRACTOR SHALL COORDINATE PRIOR TO ORDERING.PROVIDE LLI
<br /> SEISMIC BRACING AND ASME RATINGS. CI W
<br /> SIZE OF PIPE 1/2" 3/4" 1° 1-1/4" 1-1/2" LI
<br /> WATER LINE MAXIMUM GPM 5 12 20 30 40 al co
<br /> SIZING PIPING SYSTEMS INSULATION SCHEDULE = Li]MAXIMUM WFU 5 15 30 55 85 Z
<br /> INSULATION
<br /> PIPING IS BASED ON THIS STATED PRESSURE AND DISTANCE,PLUMBUING CONTRACTOR SHALL FIELD VERIFY EXISTING SPACE CONDITIONS TYPE OF PIPE INSTALLATION LOCATION INSULATION TYPE PIPE SIZE(INCH) THICKNESS(INCH) NOTES LLI <
<br /> AND REPORT ANY DISCREPANCIES TO THHE BUILDING OWNER.COPPER TUBING TYPE M,L,K. ---- - - - -- - -- - -- - > i
<br /> INSIDE BUILDING ENVELOPE FIBERGLASS ALL SIZES 1"THICK 1 Q (-
<br /> MAXIMUM LOADING OF DRAINAGE&VENT PIPE - - 01
<br /> OUTSIDE BUILDING MULTIPLE LAYERS FOR
<br /> SIZE OF PIPE I 1-1/2" I 2" I 3" I 4" 5 COLD PLUMBING PIPING ENVELOPE AND BURIED ELASTOMERIC ALL SIZES 1-1/2"TOTAL 1,3 h
<br /> MAXIMUM UNITS DRAINAGE PIPE THICKNESS N
<br /> WASTE LINE IN TRENCHES AND 0
<br /> SIZING
<br /> VERTICAL 2 16 48 256 600
<br /> UTILIDORS CELLULAR GLASS ALL SIZES 1"THICK 2
<br /> '-
<br /> HORIZONTAL 1 8 35 216 428 - 1-1/4 INCH AND
<br /> VENT PIPING 8 24 84 256 600 SMALLER 1"THICK
<br /> INSIDE BUILDING ENVELOPE FIBERGLASS -
<br /> 1-1/2 INCH AND
<br /> BASED ON 1/4"PER FOOT SLOPE,MULTIPLY BY 0.8 FOR 1/8"SLOPE 1-1/2"THICK 1
<br /> HOT PLUMBING PIPING LARGER OUTSIDE BUILDING ELASTOMERIC ALL SIZES 1-1/2"THICK 1
<br /> WATER HEATER SIZING CALCULATION ENVELOPE AND BURIED
<br /> FIXTURE HW FLOW RATE(GPH) QUANTITY TOTAL FLOW RATE(GPH) IN TRENCHES AND CELLULAR GLASS ALL SIZES 1-1/2"THICK 1,3
<br /> UTILIDORS
<br /> HAND SINK 5 5 25 NOTES: JOB NO:----
<br /> LAB SINK 5 3 15 ISSUE DATE
<br /> - 1-INCLUDE POLYETHYLENE TUBING.
<br /> TOTAL HW FLOW RATE(GPH) 40 2-INCLUDE MULTI-PLY LAMINATE JACKET.
<br /> DEMAND FACTOR 0.50 3-INCLUDE FACTORY APPLIED WEATHER PROOF JACKET OR MANUFACTURER RECOMMENDED COATING.
<br /> STORAGE FACTOR 1.00 -- - - -
<br /> PROBABLE DEMAND 20.00
<br /> REQUIRED STORAGE(GAL) 40.00
<br /> HOT WATER REQUIRED(GAL) 60.00
<br /> PS BURM
<br /> vre
<br /> ivitfr)
<br /> ilip,„ ,,1/4.. .,
<br /> 1 .„,w,..:00
<br /> No.,,-.
<br /> SCHEDULES
<br /> _ P0.3