Laserfiche WebLink
N <br />DEMO FLOOR PLAN <br />1 1/4' • T-0' <br />N <br />FLOOR PLAN <br />2 1/4' 1'-0' <br />STRUCTURAL NOTES: <br />SEE DCI STRUCTURAL ENGINEER MEMO FOR BELOW FLOOR UNISTRUT BRACING <br />REQUIRED AT THE SIEMENS TABLE BASE PLATE AND WALL STAND. <br />ROOM FINISH SCHEDULE <br />ROOM NO. <br />ROOM NAME <br />WALLS <br />CEILING <br />REMARKS <br />FLOOR <br />BASE <br />NORTH <br />SOUTH <br />EAST <br />WEST <br />WAINSCOT <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />HEIGHT <br />101 <br />FLUORO ROOM 7 <br />S.VINYL <br />SV-1 <br />EXIST. <br />- <br />EXIST. <br />P-1 <br />EXIST. <br />P-1 <br />EXIST. <br />P-I <br />EXIST. <br />P-I <br />EXIST. <br />ACT <br />sl - <br />102 <br />CONTROL ROOM <br />S.VINYL <br />SV-1 <br />EXIST. <br />- <br />EXIST. <br />P-1 <br />EXIST. <br />P-1 <br />EXIST. <br />P-I <br />EXIST. <br />P-1 <br />EXIST, <br />EXIST. <br />ACT <br />9'-6" <br />INTERIOR FINISH SPECIFICATIONS <br />SYMBOL <br />ITEM <br />MANUFACTURER <br />NOTES <br />P-I <br />PAINT <br />MFG: BENJAMIN MOORE <br />COLOR: OC-18 DOVE WING <br />FINISH: REGAL SELECT INTERIOR EGGSHELL <br />SV-1 <br />SEAMLESS <br />SHEET <br />VINYL <br />MFG: TOLI <br />COLOR: MATURE WOODS <br />772 CLASSIC VERMONT MAPLE <br />DEMOLITION <br />KEYNOTES <br />F. KEYNOTE <br />LO EXISTING TABLE BASE PLATE <br />LI EXISTING SYSTEM GENERATOR <br />CABINET TO BE REMOVED <br />L2 EXISTING WALL STAND MOUNTING <br />PLATE TO BE REMOVED <br />13 REMOVE EXISTING S. VINYL <br />FLOORING UP TO INTEGRAL COVE <br />BASE AND AREAS IDENTIFIED <br />L4 EXISTING SINK AND CASEWORK UNIT <br />IS EXISTING EPO BUTTON <br />L6 EXISTING COMBINATION CODE/STAFF <br />ASSIST DEVICE <br />1.7 EXISTING MED GAS (1)0, (I)MV <br />Le, EXISTING CONTROL COUNTERTOP <br />1.9 EXISTING WALL MOUNTED GRID <br />HOLDER TO BE REMOVED <br />FLOOR PLAN <br />KEYNOTES <br />O# KEYNOTE <br />LO SEE SIEMENS DRAWINGS FOR <br />CONTROL ROOM EQUIPMENT <br />LI EXISTING EPO BUTTON <br />1.2 EXISTING COMBINATION CODE/STAFF <br />ASSIST DEVICE <br />L5 NEW HEAT WELDED S. VINYL <br />FLOORING INTEGRATED INTO THE <br />REMAINING EXISTING COVE BASE <br />(SEE DEMO PLAN WHERE THE COVE <br />BASE REMAINS) <br />1.4 EXISTING SINK AND CASEWORK UNIT <br />IS EXISTING MED GAS (1)0, (I)MV <br />L6 LUMINOS AGILE MAX TABLE (SEE <br />SIEMENS DRAWINGS) <br />1.7 POLYPOROS GENERATOR <br />CABINET(SEE SIEMENS DRAWINGS) <br />G.C. TO INSTALL WALL BACKING B <br />FASTEN CABINET TO WALL <br />IB YSIO MAX WALL STAND (SEE <br />SIEMENS DRAWINGS) <br />1.9 WALL MOUNTED GRID HOLDER (SEE <br />SIEMENS DRAWINGS) G.C. TO <br />MOUNT TO EXISTING WALL BACKING <br />LIO MOBILE DETECTOR HOLDER ON <br />WHEELS (SEE SIEMENS DRAWINGS) <br />1.11 NEW SURFACE MOUNTED RACEWAY <br />(SEE ELECTRICAL) <br />L12 NEW SURFACE MOUNTED WIREMOLD <br />(SEE ELECTRICAL) <br />2727 Oakes Ave. <br />Suite 100 <br />Everett, WA 98201 <br />REVISIONS <br />37 <br />7 <br />REGISTERED <br />ARCHITECT <br />NDREW H LL <br />STATE OF WASHINGTO <br />is <br />Oe �. 28-1021 <br />ow,wri ev i lZ <br />CH —Ea ar' IDS <br />DOM SUBMITTAL <br />j-26-2024 <br />DEMO & FLOOR <br />PLAN <br />