SPECIFICATIONS: <br />1. THE GENERAL, SUPPLEMENTARY AND OTHER CONDITIONS OF THE CONTRACT, <br />21. DEFINITIONS <br />27. WIRING <br />MODIFICATIONS TO THE GENERAL CONDITIONS, THE DRAWINGS, AND THE APPLICABLE <br />PROVISIONS OF THE OTHER DIVISIONS AR HEREBY MADE APART OF THIS DIVISION AND <br />A. <br />THE TERM "CONTRACTOR" USED THROUGHOUT THESE SPECIFICATIONS AND ON <br />A. <br />ALL WIRING SHALL BE ENCLOSED WITHIN THE RACEWAY SYSTEM. <br />ALL ITS SECTIONS. <br />THE ELECTRICAL DRAWINGS SHALL BE UNDERSTOOD TO MEAN THE ELECTRICAL <br />CONTRACTOR. ALL OTHER WORK SHALL BE CALLED OUT BY NAME. <br />B. <br />PROTECT"OPEN" CABLE WIRING FROM ROUGH AND/OR SHARP EDGES ON <br />2. THE REQUIREMENTS OF THIS SECTION APPLY TO ALL ELECTRICAL WORK. <br />SUPPORTS, STRUCTURAL MEMBERS, ETC. AS REQUIRED DURING INSTALLATION. <br />B. <br />"FURNISH" MEANS TO SUPPLY AND DELIVER TO THE PROJECT, READY FOR <br />3. COORDINATE ELECTRICAL WORK WITH RELATED WORK SHOWN AND SPECIFIED <br />INSTALLATION AND IN OPERABLE CONDITION. <br />C. <br />WIRE AND CABLE SIZES INDICATED AND/OR SPECIFIED ARE MINIMUMS ONLY AND <br />ELSEWHERE. <br />SHALL BE INCREASED AS REQUIRED DUE TO NEC, SYSTEM, LOAD, <br />C. <br />"INSTALL" MEANS TO INCORPORATE IN THE WORK FINAL POSITION, COMPLETE, <br />VOLTAGE DROP, ETC. REQUIREMENTS. <br />4. WORK INCLUDED: THE CONTRACTOR SHALL PERFORM ALL THE WORK REQUIRED <br />ANCHORED, CONNECTED, AND IN OPERABLE CONDITION. <br />(INCLUDING THE FURNISHING OF ALL SUPERVISION, LABOR, SERVICES, TOOLS, <br />D. <br />BRANCH CIRCUIT& EQUIPMENT GROUND CABLES WITHIN A CONDUIT SYSTEM <br />MATERIALS AND EQUIPMENT AND THE PERFORMANCE OF ALL OPERATIONS AND <br />D. <br />"PROVIDE" MEANS FURNISH AND INSTALL. <br />SHALL BE 11C COPPER STRANDED, #12 AWG (UNLESS NOTED OTHERWISE), WITH <br />INCIDENTALS NECESSARY) FOR A COMPLETE, SAFE AND RELIABLE ELECTRICAL <br />600V TYPE XHHW OR THHN/THWN INSULATION. <br />INSTALLATION, ADJUSTED, TESTED AND READY FOR OPERATION. THE ELECTRICAL WORK <br />E <br />F.O. I.C. - FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR. <br />(NEW AND MODIFICATION OF EXISTING) IS GENERALLY DESCRIBED AS FOLLOWS: <br />E. <br />CABLE SHALL BE UNROLLED FROM REELS, OR REMOVED FROM CARTONS, AND <br />22. SUBMITTALS <br />INSTALLED IN A MANNER WHICH WILL PREVENT KINKING, CRUSHING OR EXCESSIVE <br />A. DEMOLITION. <br />TENSION ON CONDUCTORS AND INSULATION. CABLE PULLING LUBRICANTS OF A <br />B. GROUNDING. <br />A. <br />PROVIDE SUBMITTALS TO THE ENGINEER, TOGETHER, AT ONE TIME, SEPARATED AND <br />TYPE HAVING NO DAMAGING EFFECT ON THE INSULATION, SHALL BE USED TO <br />C. WIRING DEVICES AND SPECIAL PURPOSE RECEPTACLES. <br />INDEXED FOR EACH SPECIFICATION SECTION. INDIVIDUAL OR INCOMPLETE <br />MINIMIZE PULLING STRESSES ON THE CABLE. <br />D. LIGHTING FIXTURES. <br />SUBMITTALS ARE NOTACCEPTABLE. <br />E. LIGHTING CONTROLS, <br />F. <br />CABLE SHALL BE INSTALLED OR DRAWN INTO THE CONDUIT SYSTEM ONLY AFTER <br />F. BRANCH CIRCUIT WIRING SYSTEM FOR LIGHTING, OUTLETS, EQUIPMENT, ETC. <br />B. <br />THE ENGINEER WILL REVIEW EACH SUBMITTAL, INDICATE ACTION TO BE TAKEN, <br />ALL WORK OF ANY NATURE THATCOULD CAUSE INJURY TO THE CABLE IS <br />G. DISCONNECTING MEANS, SWITCHES, RECEPTACLES, MOTOR STARTERS, CONTROL <br />AND RETURN. THE CONTRACTOR SHALL ALLOW FOR 1 1/2 WEEKS FOR ENGINEER <br />COMPLETED. THE CONDUIT SYSTEM SHALL BE COMPLETE, SNAKED AND CLEANED <br />DEVICES, ETC. (INSTALLATION ONLY IF FURNISHED WITH EQUIPMENT), AND FINAL <br />REVIEW MINIMUM. COMPLIANCE WITH SPECIFIED CHARACTERISTICS IS THE <br />BEFORE PULLING ANY CABLE. <br />POWER AND LINE VOLTAGE (120 VOLT OR GREATER) CONTROL CONNECTIONS TO <br />CONTRACTOR'S RESPONSIBILITY. APPROVAL OF SUBMITTALS DOES NOT RELEASE <br />EQUIPMENT AND DEVICES PROVIDED BY THE OWNER, GENERAL CONTRACTOR OR <br />THE CONTRACTOR FROM A PROPER INSTALLATION, COMPLIANCE WITH THE <br />28. GROUNDING: <br />OTHER SUB -CONTRACTORS, INCLUDING THE FOLLOWING. <br />DRAWINGS, SPECIFICATIONS, CODES, STANDARDS, SITE CONSTRAINTS, ETC. OR <br />1. FLUOROSCOPY IMAGING EQUIPMENT <br />COORDINATION OF THE WORK. <br />A. <br />ALL ELECTRICAL EQUIPMENT, BOXES, DEVICES, SHALL BE PROVIDED WITH A <br />H. LINE VOLTAGE (120 VOLT OR HIGHER) CONTROL STATIONS, DEVICES, CONDUIT, <br />GROUND FAULT RETURN PATH BY MEANS OF THE INTEGRITY OF THE METALLIC <br />I. BOXES, WIRING, ETC. (INSTALLATION ONLY IF FURNISHED WITH IMAGING EQUIPMENT) <br />C. <br />PROVIDE SUBMITTALS FOR THE FOLLOWING: <br />CONDUITSYSTEM (WHERE APPLICABLE) & AN INSULATED GROUNDING <br />J. SUPPORTS. <br />CONDUCTOR INSTALLED WITH THE CIRCUIT CONDUCTORS. CONDUIT SHALL BE <br />K. TRENCHING AND BACKFILLING FOR UNDERGROUND ELECTRICAL WORK. <br />1. CIRCUTBREAKER. <br />CLOSELY & TIGHTLY FITTED IN COUPLINGS, CONNECTORS, ETC. AND BE PROPERLY <br />L TEMPORARY CONSTRUCTION POWER AND LIGHTING. <br />2, LIGHTING FIXTURES & LIGHTING CONTROLS <br />BONDED TO PROVIDE AN ELECTRICALLY CONTINUOUS LOW RESISTANT GROUND <br />M. TESTING AND COMPLETING. <br />PATH. CONTINUITY TESTS SHALL BE MADE TO VERIFY THE CONTINUITY OF THE <br />N. OBTAINING AND PAYING FOR ALL REQUIRED LICENSES, PERMITS, INSPECTIONS AND FEES. <br />23. DEMOLITION <br />GROUNDING SYSTEM & ALL GROUND FAULT RETURN PATHS. <br />5. WORK NOT INCLUDED. THE FOLLOWING ELECTRICAL SYSTEM RELATED WORK WILL BE <br />A. <br />CONTRACTOR SHALL REMOVE EXISTING EQUIPMENT, FIXTURES, DEVICES, ETC. AS <br />B. <br />EQUIPMENTGROUND CABLES SHALL BE 1/C COPPER, WITH 600V TYPE XHHW OR <br />PROVIDED BY THE OWNER, GENERAL CONTRACTOR, OR OTHER SUBCONTRACTORS WORKING <br />INDICATED IN THE WORK AREA AND ALL ASSOCIATED CONDUIT, BOXES, <br />THHN/THWN INSULATION. <br />DIRECTLY WITH THE OWNER: <br />CABLES, ETC. SHALL BE REMOVED TO THEIR POINTOF ORIGIN &JOR DESTINATION. <br />29. SEPARATELY MOUNTED CIRCUIT BREAKERS: <br />A. IMAGING EQUIPMENT INSTALLER'. EQUIPMENT CABLING, EQUIPMENT, CONNECTIONS, <br />g. <br />UNLESS NOTED OTHERWISE, CONCEALED RACEWAYS ARE ALLOWED TO REMAIN, <br />CONTROL WIRING, DEVICES, ETC. <br />EXCEPT, WIRING SHALL REMOVED EXISTING CONCEALED RACEWAYS ARE <br />A. <br />CIRCUIT BREAKERS SHALL BE BOLT -ON, MOLDED -CASE, THERMAL MAGNETIC, <br />ALLOWED TO BE RE -USED IF IN GOOD CONDITION &SUITABLE FOR THE NEW <br />QUICK MAKE -QUICK BREAK TYPE WITH TRIP INDICATING HANDLES, SUITABLE FOR <br />fi. BEFORE SUBMfTT1NG BID, EXAMINE EXISTING BUILDING AND EQUIPMENT CONDITIONS TO <br />INSTALLATION. <br />USE AS SERVICE ENTRANCE EQUIPMENT WHERE REQUIRED. CIRCUIT BREAKERS <br />DETERMINE EFFECT ON EXECUTION OF THE ELECTRICAL WORK AND INCLUDE COSTS IN <br />SHALL BE PROVIDED WITH HANDLE LOCKING DEVICES WHERE REQUIRED. <br />BID. <br />C. <br />EXISTING FEEDERS, CIRCUITS, CONDUITS, CABLES, ETC. INTERRUPTED DUE TO THE <br />MULTI -POLE BREAKERS SHALL BE SINGLE -HANDLE, INTERNAL COMMON TRIP. MAIN <br />SYSTEM UPGRADE SHALL BE RE -CONNECTED AS REQUIRED TO MAINTAIN THE <br />AND/OR FEEDER AND BRANCH CIRCUIT BREAKERS SHALL BE SERIES SHORT <br />7. EXISTING CIRCUITS INDICATED ON THE PLANS ARE BASED ON WHAT WAS SHOWN <br />ORIGINAL FUNCTION. <br />CIRCUIT RATED. PROVIDE PADLOCKING DEVICES ON CIRCUIT BREAKERS WHERE <br />T <br />THE ORIGINAL CONSTRUCTION DRAWINGS AND MAN NOT BE EXACTLY HOW THE ACTUAL <br />REQUIRED. <br />CONSTRUCTION WAS DONE. THE CONTRACTOR SHOULD EXPECT THAT SOME AMOUNT OF <br />D. <br />ALL SURPLUS MATERIAL REMOVED DURING THE DEMOLITION SHALL BE INSPECTED <br />CIRCUIT TRACING TO DETERMINE WHO THE ACTUAL CIRCUITS ARE INSTALLED WILL BE <br />BY THE OWNER, AND THOSE ITEMS SELECTED SHALL REMAIN THE PROPERTY OF <br />B. <br />CIRCUIT BREAKERS SHALL BE IDENTIFIED WITH LAMINATED NAMEPLATES, BLACK <br />REQUIRED. <br />THE OWNER. ALL REMAINING SURPLUS MATERIALS SHALL BE REMOVED FROM THE <br />FACE, WHITE CORE, ENGRAVED WITH MINIMUM 1/41NCH LETTERS. <br />SITE & DISPOSED OF BY THE CONTRACTOR ACCORDING TO ALL APPLICABLE <br />8. THE CONTRACTOR SHALL COORDINATE THE WORK AND COOPERATE WITH THE OWNER, <br />REGULATIONS. <br />30. WIRING DEVICES <br />OTHER TRADES, AND SYSTEM CONTRACTORS TO HAVE THE WORK COMPLETED TO THE <br />BESTADVANTAGE, INSURE THERE ARE NO INTERFERENCES, PROVIDE REASONABLE <br />24. RACEWAYS <br />A. <br />WIRING DEVICES SHALL BE HOSPITAL GRADE, RED COLOR ON CRITICAL BRANCH AND <br />OPPORTUNITY FOR THE OTHER TRADES AND CONTACTORS TO COMPLETE THEIR WORK <br />IVORY COLOR ON NORMAL BRANCH. <br />AND TO NOT DELAY THE WORK. <br />A. <br />RACEWAYS SHALL BE OF THE TYPES LISTED BELOW, UNLESS NOTED OTHERWISE: <br />B. <br />GENERAL PURPOSE OUTLETS SHALL BE STRAIGHT BLADE, 15 AMP, 125 VOLT <br />9. THE ELECTRICAL PLAN DRAWINGS ARE GENERAL IN FORM AND DO NOTATTEMPTTO SHOW <br />COMPLETE DETAILS OR LIST EVERY ITEM OF THE ELECTRICAL SYSTEMS, THE BUILDING <br />1. ELECTRICAL METALLIC TUBING (EMT) - CONCEALED ABOVE GRADE AND EXPOSED IN <br />C. <br />GROUND FAULT INTERRUPTER (GFI) TYPE RECEPTACLES SHALL BE DUPLEX CLASS <br />CONSTRUCTION OR THE VARIOUS EQUIPMENT (NEW OR EXISTING)', HOWEVER, THE ROUTING <br />UTILITY ROOMS AND OTHER NON-PUBLIC AREAS NOT READILY VISIBLE TO BUILDING <br />q, 15 AMP, 125 VOLT. <br />OF RACEWAYS AND CIRCUITS, AND THE LOCATIONS OF EQUIPMENT, DEVICES, FIXTURES, <br />OCCUPANTS. <br />ETC. REPRESENT THE DESIRED FINISHED ARRANGEMENT; EXCEPT, AS GOVERNED BY <br />D. <br />FLUSH MOUNTED DEVICES SHALL HAVE SMOOTH STAINLESS STEEL WALLPLATES. <br />STRUCTURAL OR MECHANICAL CONDITIONS OR OBSTRUCTIONS. <br />. <br />2FLEX- SHALL BE USED FOR FINAL CONNECTIONS TO VIBRATING EQUIPMENT& <br />MAY BE SUBSTITUTED FOR EMT WHEN RUN CONCEALED WITHIN WALLS & <br />CEILINGS WITHIN THE LIMITS OF NEC 517, <br />F. <br />ALL OUTLETS SHALL BE LABELED WITH THE PANEL AND CIRCUIT NUMBER(S) FROM <br />10. CONTRACTOR SHALL COORDINATE WORK TO AVOID DISTURBANCE TO BUILDING <br />WHICH HE DEVICE IS FED. LABELS SHALL BE HEAVY DUTY ADHESIVE TYPE, CLEAR <br />OPERATIONS AND PERSONNEL, AND TO ALLOW ACCESS FOR BOTH PERSON TO AND <br />WITH BLACK LETTERS ON LIGHT COLORED DEVICES AND CLEAR WITH WHITE <br />WITHIN ALL PORTIONS OF THE FACILITY AND VEHICLES TO THE FACILITY. ACCESS TO <br />3. MC CABLE -MAY NOT BE USED, EXCEPT FOR FIXTURE WHIPS INACCESSIBLE <br />LETTERS ON DARK COLORED DEVICES. LETTERING SHALL BE 1/4" MINIMUM. <br />OFFICE SPACES, CLASSROOMS, ETC. WILL NOT BE ALLOWED WHEN THEY ARE OCCUPIED. <br />CEILING SPACE. <br />SELF-ADHESIVE CIRCUIT NUMBERS, MASKING TAPE, PLASTIC PUNCH TYPE "DYMO" <br />S ANY AND ALL COSTS INCURRED FO NON STANDARD HOURS, DOUBLE SHIFTS, OVERTIME, <br />LABELS, ETC. ARE NOTACCEPTABLE. <br />ETC. OR ANY OTHER COSTS ASSOCIATED WITH COMPLETING THE PROJECT WITHIN THE <br />COMPLETION TIMES REQUIRED SHALL BE INCLUDED WITHOUT INCREASE IN CONTRACT <br />g <br />RACEWAYS AND CABLES THROUGHOUT THE FACILITY SHALL BE RUN CONCEALED IN <br />31. CONTROL <br />STATIONS AND DEVICES <br />SUM. <br />THE WALLS, ABOVE THE CEILING OR BELOW THE FLOOR WHERE POSSIBLE, EXCEPT, <br />EXPOSED WITHIN UTILITY &OTHER NON-PUBLIC SPACES. WITHIN PUBLIC SPACES, <br />A. <br />PUSHBUTTONS, SELECTOR SWITCHES, POTENTIOMETERS, INDICATING LIGHTS, ETC. <br />11. THE COMPLETED INSTALLATION SHALL DONE IN A NEAT& WORKMANLIKE MANNER, <br />WHERE DUE TO THE BUILDINGS CONSTRUCTION, IT IS NOT POSSIBLE TO ROUTE <br />SHALL BE HEAVY-DUTY TYPE, OIL -TIGHT TYPE. CONTACTS SHALL BE RATED MINIMUM <br />SHALL SUITABLE FOR THE LOCATION, AND SHALL BE ACCORDANCE ALL LAWS, <br />, <br />RACEWAYS &CABLES CONCEALED, RACEWAYS MA BE RUN EXPOSED WHEN <br />300 VOLT, 10 AMP AC AND DC CONTINUOUS. INDICATING LIGHTS SHALL BE PROVIDED <br />& <br />RULES &REGULATIONS IN EFFECT ATTHE SITE (INCLUDING THE LATEST EDITIONS OF <br />N <br />APPROVED BY ARCHITECT EXPOSED RACEWAYS SHALL BE RUN AS NEATLY & <br />WITH THE LENS COLOR INDICATED. VOLTALL HIGHER INDICATING LIGHTS SHALL BE <br />THE NATIONAL ELECTRICAL CODE, THE WASHINGTON STATE RULES &REGULATIONS <br />UNOBTRUSIVELY AS POSSIBLE, SUPPORTED AS REQUIRED, PARALLEL OR AT RIGHT <br />DEVICES <br />TRANSFORMER TYPE. CONTROL DEVICES SHALL BE ALLEN-BRADLEY BULLETIN 800T, <br />FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, AND THE WASHINGTON STATE <br />ANGLES TO CEILINGS, WALLS & STRUCTURAL MEMBERS. <br />OR APPROVED EQUAL <br />ENERGY CODE). <br />C. <br />RACEWAYS SHALL BE SIZED SO THAT THE CABLE FILL DOES NOT EXCEED 40%, <br />B. <br />CONTROL STATIONS, DEVICES, ETC. SHALL BE FLUSH MOUNTED WITH HEAVY DUTY <br />12. CONTRACTORS ARE RESPONSIBLE FOR DETERMINING THE FIRE RATINGS <br />EXCEPT, MINIMUM CONDUIT (& EQUIVALENT SURFACE METAL RACEWAY) SIZES <br />STEEL COVERS AND BOXES AS REQUIRED. <br />FOR WALLS, PARTITIONS AND OTHER BUILDING STRUCTURES. INSTALLATION OF <br />I STALL TI <br />SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: <br />NEW SYSTEM COMPONENTS MUST MAINTAIN THE EXISTING FIRE RESISTIVE <br />C. <br />EMERGENCY SHUTDOWN PUSHBUTTON (EPO) SHALL BE SURFACE MOUTNED, GUARDED <br />RATING OF THE PENETRATED BUILDING ELEMENT. <br />A. 3/4" -BRANCH CIRCUITS, EXCEPTAS NOTED OTHERWISE. <br />HEAD, RED COLOR, WITH AUDILHARY CONTACTS AND ENGRAVED NAMEPLATE INDICATING <br />13. ALL SYSTEMS, EQUIPMENT, DEVICES, RACEWAYS, CABLES, ETC. INDICATED ARE <br />D. <br />ELECTRICAL METALLIC TUBING SHALL BE ELECTRO-GALVANIZED STEEL <br />ITS FUNCTION. <br />NEW UNLESS NOTED OTHERWISE. <br />D <br />TERMINAL BLOCKS CLAMP OR SCREW TYPE SHALL BEPROVIDED FOR ALL EXTERNAL <br />E. <br />NO CONDUIT SHALL BEND MORE THAN 270 DEGREES BEFORE THE END OF ITS <br />WIRES ENTERING CONTROL STATIONS, ETC. WHERE SUITABLE TERMINALS ARE NOT <br />14. ALL ELECTRICAL MATERIALS SHALL BE "UL" (UNDERWRITER'S LABORATORIES, INC.) <br />RUN. BENDS IN CONDUITS SHALL BE MADE WITHOUT FLATTENING, KINKING OR <br />AVAILABLE ON THE DEVICE. CONTROL WIRES SHALL NOT BE SPLICED OR TAPPED USING <br />LISTED, LABELED AND APPROVED FOR THE SERVICE INTENDED WHERE UL STANDARDS <br />REDUCING THE CROSS -SECTIONAL AREA OF THE CONDUIT. CONDUIT CUTS SHALL <br />WIRE NUTS WITHOUTAPPROVAL FROM THE ENGINEER. <br />HAVE BEEN ESTABLISHED. ALL ELECTRICAL MATE RHAL SHALL BE NEW UNLESS <br />BE MADE SQUARE WITH A PROPER CUTTING TOOL. THE INSIDE AND OUTSIDE OF <br />SPECIFICALLY NOTED OTHERWISE. <br />ALL CONDUIT ENDS SHALL BE REAMED TO ELIMINATE BURRS AND ROUGH EDGES, <br />E. <br />EACH DEVICE SHALL HAVE A SUITABLE LEGEND. <br />THEN WIPED CLEAN. <br />15. ALL OPERATIONS SHALL BE CONDUCTED IN A MANNER TO AVOID THE RISK OF HARM TO <br />F. <br />CONTROL STATIONS, ETC. SHALL BE IDENTIFIED WITH LAMINATED PLASTIC NAMEPLATES, <br />PERSONS OR DAMAGE TO PROPERTY. DAMAGE SHALL IMMEDIATELY BE REPAIRED. <br />F. <br />SUITABLE BUSHINGS SHALL BE USED ON ALL CONDUIT TERMINATIONS. <br />BLACK FACE, WHITE CORE, ENGRAVED WITH MINIMUM 1181NCH LETTERS <br />CONSTRUCTION EQUIPMENT & TOOLS SHALL BE IN GOOD OPERATING CONDITION, AND <br />DESCRIBING ITS FUNCTION. <br />BE DESIGNED FOR THE WORK REQUIRED. VERIFY WITH STRUCTURAL ENGINEER <br />G. <br />CONDUITSYSTEMS SHALL BE COMPLETE, SNAKED AND CLEANED BEFORE <br />ACCEPTABLE LOCATIONS FOR CORE DRILLING FLOORS, WALLS, ETC. FOR CONDUIT <br />PULLING ANY CABLE. <br />32. LIGHTING <br />ROUTING <br />25. RACEWAY FITTINGS <br />A. <br />LIGHT EMITTING DIODE (LED) LUMINAIRES SHALL HAVE A LUMINOUS EFFICIENCY OF <br />16. POWER INTERRUPTIONS (WHETHER TO THE ENTIRE SYSTEM ORTO INDIVIDUAL <br />AT LEAST 100 LUMENS/W, AN ESTIMATED LIFE OF AT LEAST60,000 HOURS AT70% <br />BUILDINGS, PANELS, EQUIPMENT, DEVICES, ETC.) SHALL BE KEPTTO AN ABSOLUTE <br />A. <br />CONNECTORS, COUPLINGS, ETC. FOR EMTSHALL BE STEEL SET -SCREW TYPE, <br />LUMEN MAINTENANCE, AND SHALL INCLUDE A MINIMUM 5-YEAR WARRANTY ON <br />MINIMUM, AND SHALL NOT BE DONE WITHOUT PRIOR APPROVAL, 2 WEEKS <br />EXCEPT, STEEL RAINTIGHT COMPRESSION TYPE IN POTENTIALLY WET OR DAMP <br />THE ENTIRE LUMINAIRE INCLUDING THE DRIVER. THE LUMINAIRE AND LEDS SHALL <br />ADVANCED SCHEDULING & COORDINATION MEETING WITH THE OWNER. SECONDARY <br />LOCATIONS. <br />HAVE BEEN TESTED IN ACCORDANCE WITH LM-79 AND LM-80. <br />VERIFICATION THAT POWER INTERRUPTION WILL OCCUR IS ALSO REQUIRED 48 HOURS <br />PRIOR TO THE DATE OF OCCURRENCE. <br />26. BOXES <br />B. <br />FIXTURES, LUMINAIRES, POLES, ETC. SHALL INCLUDE ALL NECESSARY MOUNTING <br />AND CONNECTING ACCESSORIES. <br />17. CABLE, BOXES, ETC. SHALL BE STORED OFF THE GROUND, PROTECTED FROM THE <br />A. <br />BOXES SHALL ACCOMMODATE ANY DEVICES TO BE INSTALLED AND SHALL BE <br />WEATHER IN RACKS OR BINS, OR ON SHELVES. EQUIPMENT, WIRING DEVICES, CIRCUIT <br />SIZED AS REQUIRED BY THE APPLICABLE CODES FOR NUMBERAND SIZE OF <br />C. <br />CONTRACTOR & LIGHTING FIXTURE SUPPLIER SHALL VERIFY DESCRIPTION & <br />BREAKERS, ETC. SHALL BE STORED INDOORS IN A DRY, WARM AREA, FREE OF DUST & <br />CONDUITS AND CABLES ENTERING AND LEAVING, EXCEPTMINIMUM AS NOTED <br />CATALOG NUMBERS IN LIGHTING FXTURE SCHEDULE ON THE DRAWINGS MATCH <br />ONE IN WHICH CONDENSATION WILL NOTOCCUR. <br />BELOW. <br />AND MOUNTING REQUIREMENTS ARE CORRECT ADVISE ENGINEER OF ANY <br />CONFLICTS OR DISCREPANCIES. <br />18. EQUIPMENT, BOXES, ETC. SHALL BE INSTALLED PLUMB & TRUE, AND BE FIRMLY <br />B. <br />INDOOR BOXES ABOVE GRADE IN DRY LOCATIONS SHALL BE STANDARD STAMPED <br />SUPPORTED EITHER DIRECTLY OR INDIRECTLY BY A SOUND & SAFE STRUCTURAL <br />GALVANIZED STEEL TYPE, SUITABLE FOR EMBEDMENT IN CONCRETE AND/OR <br />33. LIGHTING CONTROLS <br />MEMBER. <br />MASONRY WHERE REQUIRED. <br />A. <br />LINE VOLTAGE DIMMER SWITCHES SHALL BE COMBINATION SINGLE POLE OR 3-WAY SWITCH <br />19. ROUTING OF EXISTING CONDUITS INDICATED IS APPROXIMATE ONLY. <br />C. <br />UNLESS NOTED OTHERWISE, LARGER SIZE PULL AND JUNCTION BOXES SHALL BE <br />WITH SLIDE DIMMER, 120/277V RATED SWITCH WITH SEPARATE 0-10V CONTROL OUTPUT, <br />FABRICATED FROM CODE GAUGE GALVANIZED STEEL. <br />SUITABLE FOR USE AS A STAND-ALONE WALL BOXSWITCH, IVORY COLOR WITH STAINLESS <br />20. VERIFY ALL EQUIPMENT, DEVICE, ETC. LOCATIONS WITH THE OWNER PRIOR TO <br />WALL PLATE. SWITCHES SHALL BE WATTSTOPPER CD4FBL, GREENGATE WBSD-01CM-Cl, OR <br />ROUGH -IN. <br />D. <br />SWITCH, OUTLET, DEVICE, ETC. BOXES SHALL BE SINGLE OR GANGED TO <br />APPROVED EQUAL. <br />ACCOMMODATE THE REQUIRED NUMBER OF DEVICES; EXCEPT, FLUSH MOUNTED <br />BOXES SHALL BE MINIMUM 4 INCHES SQUARE FOR CONDUITS 1 INCH OR LESS AND <br />4-11116 INCHES SQUARE FOR LARGER CONDUITS. BOXES CONTAINING A SINGLE <br />DEVICE SHALL BE MINIMUM 1-1/2 INCHES DEEP. BOXES CONTAINING MULTIPLE <br />DEVICES SHALL BE MINIMUM 2-1/8 INCHES DEEP. FLUSH MOUNTED BOXES SHALL <br />BE EQUIPPED WITH PLASTER RINGS AND SUITABLE WALLPLATES. SURFACE <br />MOUNTED BOXES SHALL HAVE RAISED SURFACE TYPE COVERS. <br />ELECTRICAL LEGEND <br />IL GHTM <br />0Ad RECE55ED LED DOUNLIGHT <br />(Aa = FIXTURE TYPE A CONTROLLED <br />BY SWITCH 5a, TYPICAL.) <br />LED TROFFER LUMINAIRE <br />SWITCHING <br />5 <br />SINGLE POLE SWITCH <br />THREE-WAY SWITCH <br />Fa <br />LINE VOLTAGE DIMMER SWITCH <br />5e� <br />LINE VOLTAGE 3-WAY DIMMER SWITCH <br />OUTLETS <br />DUPLEX OUTLET <br />DOUBLE DUPLEX OUTLET <br />MISCELLANEOUS <br />BRANCH CIRCUIT CONDUIT, CONCEALED (OR 61MILAR <br />5LASHE5 • NO. OF CIRCUIT CONDUCTOR5 WHERE APPLICABLE) <br />HOMERJN TO LOCATION NDICATED, CONCEALED (TYPICAL) <br />- ---- +----- <br />CABLE RUN 'OPEN' IN ACCE6615LE CEILING 6PACE <br />(SLA5HE5 = N. 4 TYPE OF CABLES WHERE APPLICABLE) <br />- - - - - - - - - <br />UNDERFLOOR OR BELOW GRADE CONDUIT <br />----- <br />EXISTING CONDUIT WITH NEW CABLE <br />C <br />CONDUIT STUB UP TO ACCESSIBLE CEILING SPACE <br />m <br />JUNCTION BOX <br />O3 <br />EMERGENCY POWER OFF BUTTON <br />I� <br />PANELBOARD <br />Ex <br />EXISTING TO REMAIN <br />REX <br />REPLACE EXISTING <br />REL <br />RELOCATE EXISTING <br />GFI <br />GROUND FAULT INTERRUPTING <br />DRAWING INDEX <br />SHEET <br />DRAWING TITLE <br />EO.1 <br />ELECTRICAL - SPECIFICATIONS, LEGEND & INDEX <br />E1.1 <br />ELECTRICAL - 1st FLOOR OVERALL PLAN <br />E2.1 <br />ELECTRICAL - POWER PLAN & SCHEDULES <br />E3.1 <br />ELECTRICAL - LIGHTING PLAN & SCHEDULES <br />E4.1 <br />ELECTRICAL- EQUIPMENT CONNECTION PLAN <br />E6.1 <br />ELECTRICAL - POWER SYSTEM RISER DIAGRAM <br />E6.2 <br />ELECTRICAL - POWER SYSTEM RISER DIAGRAM <br />E6.3 <br />ELECTRICAL - POWER SYSTEM RISER DIAGRAM <br />i727 Oakes Ave. <br />Suite 100 <br />Everett, WA 95201 <br />REVISIONS <br />R. p <br />1Q ap WA A <br />O� S�I4794�G <br />ONAL T <br />O <br />0 <br />W <br />U <br />p <br />U <br />;a <br />m <br />(� <br />W <br />W <br />Q <br />OD <br />70 <br />0 <br />3 <br />L <br />0 <br />U <br />0 <br />}L <br />ILL <br />� <br />N <br />r <br />W <br />2341 <br />DeAw KL <br />BID SET <br />1-23-24 <br />ELECTRICAL - <br />SPECIFICATIONS, <br />LEGEND & <br />INDEX <br />E0.1 <br />