My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-58 2024-09-18
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
3003 W CASINO RD BLDG 40-58 2024-09-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2024 8:56:02 AM
Creation date
8/20/2024 3:42:05 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
QPS EVALUATION SERVICES INC. <br /> PS US FIELD EVALUATION REPORT <br /> Page 6 of 19 <br /> File Number: QFEN 85055-3 Model Number: Ground Control Panel Date: October 26, 2023 <br /> NFPA-70 Wiring Methods ® Yes ❑ No ❑ N/A Meets the NEC 70 requirement <br /> Guarding of Live Parts ® Yes ❑ No ❑ N/A Need tool to access <br /> Damaged Components ❑ Yes ❑ No ® N/A I None <br /> Electrical Clearances ® Yes ❑ No ❑ N/A Provided per the standard <br /> Wiring Bending Space ® Yes ❑ No ❑ N/A Provided per the standard <br /> Drawings verified to match ® Yes ❑ No ❑ N/A 7380 Series <br /> equipment <br /> Environment Suitability ® Yes ❑ No ❑ N/A Suitable for use <br /> Nameplate and Markings ® Yes ❑ No ❑ N/A Provided <br /> TESTS <br /> 5.0 Electrical testing may include but is not limited to the following: <br /> Test Result Comments <br /> Dielectric Strength Test ® Pass ❑ Fail ❑ N/A 1960VAC for 1 minute to be <br /> (Mandatory): conducted at the final inspection <br /> Leakage Current Test: ❑ Pass ❑ Fail ® N/A Hard wired <br /> Flame Test (mandatory if ❑ Pass ❑ Fail ® N/A Metal enclosure <br /> applicable): <br /> Heat Rise Testing: ❑ Pass ❑ Fail ❑ N/A All components used within their <br /> approval ratings <br /> Equipment Ground ® Pass ❑ Fail ❑ N/A Not required <br /> Resistance Test: <br /> Safety Circuit Functional Tests ® Pass ❑ Fail ❑ N/A Verified <br /> interlocks and emergency off): <br /> Abnormal Testing ❑ Pass ❑ Fail ® N/A Not required <br /> Test Equipment Used ®Dielectric Tester# 5845 ®Clamp Meter# 5699 <br /> Cal Due Date: 1-9-2024 Cal Due Date: 1-3-2024 <br /> QSD 122 Rev 06 <br /> The inspection report shall only be reproduced in full with the approval of the inspection body and the client. <br />
The URL can be used to link to this page
Your browser does not support the video tag.