My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2132 HIGHLAND AVE 2024-10-24
>
Address Records
>
HIGHLAND AVE
>
2132
>
2132 HIGHLAND AVE 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 3:03:33 PM
Creation date
8/26/2024 4:07:51 PM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND AVE
Street Number
2132
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br />PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN — USING THEIR PROSPECTIVE <br />RESIDENT BEDROOM DESIGNATIONS OF A 8 C D E AND F AND CLASSIFICATION CODE S, NS1 OR NS2. <br />SECTION 5 — BUILDING INSPECTOR'S INSPECTION CHECKLIST <br />R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br />Type S — where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. <br />Type NS1— where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R330.9 is provided to evacuate <br />residents to public area. <br />Type NS2 — where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with R330.9 are provided to <br />evacuate residents to public area. <br />SLEEPING ROOM A FE3 Type S Type NS1 O Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside JMYes O No ON/A I Smoke alarm Is installed in the bedroom <br />® <br />O <br />Bedroom door opens easily and quickly from the outside when locked <br />O <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />® <br />O <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />Rs- <br />O <br />SLEEPING ROOM B OType S 12tType NS1 10Type NS2 <br />NO <br />Closet door/s are readily openable from the inside 110 Yes O No I ON/A I Smoke alarm is installed in the bedroom <br />O <br />Bedroom door opens easily and quickly from the outside when locked <br />0 <br />O <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />O. <br />O <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />O <br />SLEEPING ROOM C E3 Type S 113 Type NS1 10 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside la Yes O No ON/A Smoke alarm is installed In the bedroom <br />Bedroom door opens easily and quickly from the outside when locked <br />M 1 <br />O <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />E3 <br />O <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />O <br />SLEEPING ROOM D 10 Type S Eq Type NS1 10 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside 10 Yes O No ON/A I Smoke alarm is installed in the bedroom <br />El <br />O <br />Bedroom door opens easily and quickly from the outside when locked <br />O <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />O <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />O <br />SLEEPING ROOM E O Type S Type NS1 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the insi delloyes 113No ON/A Smoke alarm Is installed in the bedroom <br />O <br />Bedroom door opens easily and quickly from the outside when locked <br />t <br />O <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />IP <br />O <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />® <br />O <br />SLEEPING ROOM F O Type S OType NS1 10 Type NS2 <br />YES <br />I NO <br />Closet door/s are readily openable from the inside 10 Yes O No ON/A I Smoke alarm is installed in the bedroom <br />01 <br />O <br />Bedroom door opens easily and quickly from the outside when locked <br />12 <br />1 O <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide)( <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />O <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />O <br />Implementation Date: 2021 February 01 <br />Updated: 2021 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.