VERETT <br />0 <br />Permit Inspections <br />City of Everett <br />- Ok to use 3/4" PVC line for HWT pan drain to exterior. <br />** All corrections per the 2018 UPC chapter 3,6,7,9,10. <br />*** Obtain mechanical permit for new exhaust fans and ducting. <br />PLUMB 02- <br />JASON <br />CORRECTION <br />3/28/2024 <br />3/28/2024 <br />GROUND <br />WORK/SLAB <br />MORRISSEY <br />REQUIRED <br />Notes: <br />- Corrections listed on rough inspection. <br />PLUMB 02- <br />3/28/2024 <br />3/28/2024 <br />GROUND <br />JASON <br />CANCELLED <br />see notes <br />WORK/SLAB <br />MORRISSEY <br />Notes: <br />3/28/2024 <br />3/28/2024 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />eTRAKiT Inspection Request <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />3/21/2024 4:05 PM SEID ALI <br />Please give me a call before heading at 206-261-7592 <br />Contact Name: SEID ALI <br />Site Address: 2132 HIGHLAND AVE <br />Phone:2062617592 <br />e-Mail: seidali99@gmail.com <br />Please have plumber call between 7:30 and 8:30AM to discuss corrections to avoid repeated corrections. All corrections must be completed and <br />confirmed before job can move forward. Make sure to obtain mechanical permit before next inspection. <br />Multiple corrections, list is not exhaustive. <br />Vent for main floor middle bath shower ties into toilet vent in crawlspace below flood level. <br />Vent for main floor powder bath toilet needs to be rolled above centerline of drain, This requires a 90 to horizontal off toilet flange with a wye rolled <br />above centerline. <br />Multiple nail plates need to cover 11/2" beyond outside of pipe for pex and ABS within 1" of stud face. <br />NE main floor bath shower vent has san tee on its side, in crawlspace. Must be wye rolled above centerline or greater. <br />Support all pex every 32" on horizontally and all ABS DWV every 4' horizontally, crawlspace and everywhere else. <br />Basement area; <br />Tub vent needs to roll above centerline of drain. <br />HWT relief line must be 3/4" CPVC or copper from valve to termination. Do to length of run a minimum 2" hub drain will be needed to receive relief <br />line discharge. Ok AAV for hub drain. Hub drain needs a trap primer installed be final. Ok to use new 3/4" CPVC drain for pan drain, cannot be used for <br />relief line as it has to terminate at least 6" above the ground. <br />- Basement ceiling tie in for bathroom vent and pump chamber vent cannot tie in below flood level, must tie in above floor 6" of above fixture overflow. <br />** All corrections per the 2018 UPC chapter 3,6,7,9,10. <br />*** Obtain mechanical permit for new exhaust fans and ducting. <br />4/15/2024 <br />4/15/2024 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />4/11/2024 1:43 PM SEID ALI <br />Please give me a call at 425-894-9486 <br />Contact Name: SEID ALI <br />Site Address: 2132 HIGHLAND AVE <br />Phone:2062617592 <br />e-Mail: seidali99@gmail.com <br />*** Corrections still remaining from previous inspection:- Replace medium turn 90 with long turn on shower vent below flood rim in crawlspace. Vent <br />for shower also needs to be rolled above centerline of drain per UPC chap9.- Vent for powder bath toilet needs to be rolled above centerline per UPC <br />chap 9.- Put DWV back on test. Per UPC chap 7. <br />I <br />Printed: Monday, 26 August, 2024 2 of 4 rk <br />SUPERION <br />