My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8531 EVERGREEN WAY COMMUNITY HEALTH CENTER 2025-05-28
>
Address Records
>
EVERGREEN WAY
>
8531
>
COMMUNITY HEALTH CENTER
>
8531 EVERGREEN WAY COMMUNITY HEALTH CENTER 2025-05-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2025 1:23:07 PM
Creation date
8/27/2024 11:52:36 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8531
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
644
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Janet Monda <br /> Architectural Werks, Inc. <br /> Plan Check Number: B2302-096, First Building Review <br /> March 23, 2023 <br /> 11. The building includes re-entrant corners at Grids C/8.4 and F2/5, constituting a Type 2 <br /> Horizontal Irregularity per ASCE 7-16 Table 12.3-1. The diaphragm chords should be developed <br /> into the diaphragms. The development length should be sufficient for the diaphragms to resist <br /> chord forces in addition to the diaphragm shear forces. The chord forces should be increased <br /> 25% per Section 12.3.3.4. See IBC Sections 1613.1 and 2306.1, and AWC SDPWS-15 Section <br /> 4.1.4. <br /> 12. The shear wall holdown design has not been provided in the structural calculations. The <br /> earthquake component of the uplift forces exceeds 20% of the total uplift (i.e., the earthquake <br /> force is 100% of uplift force). The earthquake component shall be increased per the provisions <br /> of ACI 318-14 Section 17.2.3.4.3. Calculations substantiating the holdown design should be <br /> submitted for review. The design load shall be determined per ASCE 7-10 Section 12.4.3.2 <br /> Equation 7 including the vertical seismic load effect per Section 12.4.2.2. The seismic holdown <br /> forces shall be calculated even when wind controls the lateral design. See IBC Sections <br /> 1604.10, 1613.1, and 1901.2. <br /> Miscellaneous: <br /> 13. The following comments should be addressed for the elevator system: <br /> a. The elevator design drawings should be included in the list of deferred on Sheet S1.00. See <br /> IBC Section 107.3.4.1. <br /> b. The design loads for the elevator system, including impact loading, should be specified in <br /> the"Design Loads" section on Sheet S1.00. When actual design loads are not available, <br /> estimated design loads should be specified for the design, and verified when the elevator <br /> design drawings are submitted for review. See IBC Sections 1603.1.8 and 1607.9.1. <br /> c. The building structure (i.e., elevator shaft and supporting floor framing) that supports <br /> components of the elevator system is included in the current submittal drawings. <br /> Calculations substantiating the design of the structure to support the elevator loads <br /> concurrently with other loads should be submitted for review. The calculations should <br /> include the evaluation of deflection limits per IBC Section 1607.9.1. The design shall <br /> consider concurrent multi-directional loading as determined by the elevator manufacturer. <br /> See IBC Sections 1604.2 and 1605. <br /> d. The connections between the elevator guide rails and the structural framing are typically the <br /> responsibility of the engineer-of-record for the building system. At a minimum, connection <br /> details between the rail bracket and structural framing are required. Calculations and <br /> details for the elevator connections to the structural framing should be submitted for review. <br /> The design shall consider concurrent multi-directional loading as determined by the elevator <br /> manufacturer. The required locations and maximum spacing for the connection points <br /> should be specified in the structural drawings. See IBC Section 107.2.1 and 1604.4. <br /> 3200 Cedar Street © 425.257.8810 0everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.