GENERAL NOTES AERIAL VIEW <br /> CODE AND STANDARDS <br /> "ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 INTERNATIONAL BUILDING CODE BLUE RAVEN <br /> (IBC),2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND ALL STATE ORV <br /> AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. <br /> 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. <br /> 1403 N. Research Way <br /> SITE NOTES/OSHA REGULATION Orem, UT 84097 <br /> 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. , ; 800.377.4480 <br /> 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. _ WWW.BLUERAVENSOLAR.COM <br /> 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. ' <br /> 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND CONFIDENTIAL-THE INFORMATION <br /> THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT - <br /> HEREIN CONTAINED SHALL NOT BE <br /> THE BUILDING OR STRUCTURE. ; USED FOR THE BENEFIT OF ANYONE <br /> EXCEPT BLUE RAVEN SOLAR NOR <br /> SHALL IT BE DISCLOSED IN WHOLE OR <br /> SOLAR CONTRACTOR - ` IN PART TO OTHERS OUTSIDE <br /> 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. • Z RECIPIENTS ORGANIZATION,EXCEPT <br /> 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PERIN CONNECTION WITH THE SALE AND <br /> THE MANUFACTURER'S INSTALLATION REQUIREMENTS. r , • 1� USE OF THE RESPECTIVE EQUIPMENT, <br /> 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OFy IP WITHOUT THE WRITTEN PERMISSION <br /> STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 'v • �� OF BLUE RAVEN SOLAR LLC. <br /> 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO r <br /> LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. <br /> 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A �.;.•t' NABC E P <br /> SUITABLE SEALING COMPOUND. <br /> 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. <br /> 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. �•�� . s CERTIFIED <br /> 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT 41 PV INSTALLATION <br /> AVAILABLE. <br /> 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC 1 PROFESSIONAL <br /> PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND �' Scott Gurney <br /> CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND y — #PV-011719-015866 <br /> LISTED FOR THE APPLICATION PER NEC 690.4(B). til <br /> 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. ` --�-- CONTRACTOR: <br /> 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) pw <br /> IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. BRS FIELD OPS <br /> • 800-377-4480 <br /> EQUIPMENT LOCATIONS ' <br /> 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT • • <br /> WILL BE PROVIDED AS PER SECTION NEC 110.26. <br /> 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS _ <br /> SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). U <br /> 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC 1•♦ <br /> APPLICABLE CODES. �r Sealed For Z Q Q <br /> 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. , I \ Existing Roof& A Cq O <br /> w, <br /> Attachment Only .Z• o�WAS LL � Mo 0-) � <br /> PROJECT INFORMATION: M �` ti0 �`` �' ��'� < N � <br /> 00 <br /> NUMBER OF STORIES: 2 <br /> ' Qr c'a C: Iii w <br /> CONDUIT RUN: Exterior , `_+�� w lam' Z (D 0) - N <br /> ECOBEE QTY: 1 d — <br /> LIGHT BULB QTY: 18 RF 46056 4 <br /> PV METER: Not RequiredDESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX .c�SS,oN G, �v 2 AL = o � N LU <br /> ROOF TYPE (1) INFORMATION: O IY <br /> WIND SPEED: 110 mph CONSTRUCTION -V-B PV1 -COVER SHEET F_ _� � >_ROOF TYPE: Comp Shingle GROUND SNOW LOAD: 25 lb/ft' ZONING: RESIDENTIAL PV2-SITE PLAN 22 'E � N Cl) N <br /> FRAMING TYPE: Manufactured Truss co M > U U <br /> WIND EXPOSURE FACTOR: C PV3- ROOF PLAN <br /> SHEATHING TYPE: PLYWOOD V 0 Lo W Q C3 <br /> ATTACHMENT: SFM Infinity Flashkit SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL x/16/23 <br /> C <br /> RACKING: Unirac SFM Infinity @ 48" OC Portrait/72"OC Landscape PV5- ELECTRICAL LINE DIAGRAM DRAWING BY: <br /> NUMBER OF ATTACHMENTS: 53 SCOPE OF WORK PV6- ELECTRICAL CALCULATIONS <br /> PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore <br /> ROOF TYPE (2) INFORMATION (IFAPPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY PV8- PLACARD Digitally signed <br /> * NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. (ALL OTHER SHEETS AS REQUIRED) <br /> PLOT DATE: <br /> *SEE SS - PRODUCT SPEC. SHEETS by John A. Calvert May 16, 2023 <br /> PROJECT NUMBER: <br /> SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: 15:55:08 -06'00' 767549 <br /> DC SYSTEM SIZE: 8.4 kW DC Snohomish County Public Utilities District <br /> AC SYSTEM SIZE: 6.09 kW AC (PUD) SHEET NAME: <br /> MODULE TYPE: (21) QCells Q.PEAK DUO BILK ML-G10+400 COVER SHEET <br /> INVERTER TYPE: Enphase IQ8A-72-2-US <br /> MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 PERMIT ISSUER: REVISION: PAGE NUMBER: <br /> City of Everett 0 PV 1 <br />