Laserfiche WebLink
FLOOR PLAN NOTES: o <br /> m Q <br /> 1.ALL EXTERIOR DIMENSIONS ARE TO THE FRAMING OR MAIN LAYER. <br /> DIMENSIONS TO OPENINGS ARE TO THE CENTER. <br /> 2.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND IS RESPONSIBLE <br /> FOR ALL DIMENSIONS(INCLUDING ROUGH OPENINGS). <br /> A202 - o <br /> GENERAL FRAMING NOTES: <br /> 1. ALL DIMENSIONAL LUMBER SHALL BE DOUGLAS FIR LARCH NO.2 AND LARGER <br /> LUMBER SHALL BE DOUGLAS FIR NO.1 OR BETTER,UNO. <br /> 2.WALL HEADERS:(2)2 X 10 OF 2 W/IK/IT TYP.UNO <br /> 3. I-JOISTS AND LVL MEMBERS MUST BE INSTALLED IN COMPLIANCE WITH THEIR <br /> LISTINGS. <br /> 4.ALL TRUSSES SHALL BE ENGINEERED AND STAMPED WITH A SEPARATE <br /> ENGINEERED DOCUMENT. <br /> 5. PRE-MANUFACTURED WOOD JOISTS&TRUSSES SHALL BE OF THE SIZE AND Z <br /> TYPE SHOWN ON THE DRAWINGS,MANUFACTURED BY THE TRUSS OR JOIST Q <br /> COMPANY.NO MEMBERS SHALL BE MODIFIED AND MUST BE INSTALLED IN J <br /> COMPLIANCE WITH THEIR LISTINGS.PROVIDE BRIDGING IN CONFORMANCE WITH <br /> THE MANUFACTURERS RECOMMENDATIONS.MEMBERS AND BRIDGING SHALL BE <br /> CAPABLE OF RESISTING THE WIND UPLIFT NOTED ON THE DRAWINGS.THE <br /> MANUFACTURER SHALL VISIT JOB SITE AS REQUIRED AND VERIFY THE PROPER r— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — O <br /> INSTALLATION OF THE JOISTS&TRUSSES IN WRITING TO THE CONTRACTOR/ O <br /> ENGINEER.PRE-MANUFACTURED WOOD JOIST ALTERNATES WILL BE I I J <br /> CONSIDERED,PROVIDED THE ALTERNATE IS COMPATIBLE WITH THE LOAD I I Z <br /> CAPACITY,STIFFNESS,DIMENSIONAL,AND FIRE RATING REQUIREMENTS OF THE <br /> PROJECT,AND IS ENGINEER OR ICBO APPROVED. <br /> 6.ALL JOISTS AND RAFTERS SHALL HAVE SOLID BLOCKING AT THEIR BEARING I O I Q <br /> POINTS.CONNECT BLOCKING TO TOP OF WALL W/SIMPSON FRAMING ANCHORS. <br /> ROOF JOIST TO HAVE HURRICANE CLIPS @ 48'O.C.OR SIMPSON H-1 HURRICANE <br /> CLIPS @ 24"0/C. INSTALL PRIOR TO ROOF SHEETING. <br /> 7.ALL WOOD&IRON CONNECTIONS MUST CARRY THE CAPACITY OF THE MEMBER. <br /> THE CONTRACTOR IS RESPONSIBLE FOR ALL CONNECTIONS.IF OTHER THAN <br /> STANDARD CONNECTIONS ARE REQUIRED,CONTACT PROJECT ENGINEER FOR <br /> ASSISTANCE.USE SIMPSON OR OTHER ICC LISTED CONNECTIONS. i [IQTHI(� LIVING BEDROOM <br /> 8.ALL HANGERS AND NAILS IN CONTACT WITH PRESSURE TREATED LUMBER <br /> SHALL BE SIMPSON Z-MAX HANGERS OR STAINLESS STEEL. <br /> 9. NAILS:ALL SHEAR WALL SHEATHING NAILS SHALL BE COMMON NAILS ALL I CARPORT "X 11 13'-4"X 8'-6" 10'-0"X 15'-0" <br /> FRAMING NAILS SHALL BE COMMON NAILS.OR HOT DIPPED GALVANIZED BOX 4 S F 113 SQ FT 151 SQ FT <br /> NAILS.FRAMING NAILS SHALL BE PER IBC TABLE 2304.9.1 OR IRC TABLE 12X16 0 <br /> RI A301 I oNa <br /> 10.THRUST SHALL BE ELIMINATED BY THE USE OF COLLAR TIES OR CEILING JOISTS, <br /> WHERE REQUIRED. A201 — — — — — — — — — — — — <br /> 11. BEVELED BEARING PLATES ARE REQUIRED AT ALL BEARING POINTS FOR BCI& I Attic Access I A201 <br /> TJI RAFTERS. F <br /> 12.ALL COLUMNS SHALL EXTEND DOWN THRU THE STRUCTURE TO THE C = <br /> FOUNDATION.ALL COLUMNS SHALL BE BRACED AT ALL FLOOR LEVELS. I I C <br /> COLUMNS SHALL BE THE SAME WIDTH AS THE MEMBERS THAT THEY ARE <br /> SUPPORTING. A301 I W <br /> 13.ALL EXTERIOR WALLS SHALL BE SHEATHED WITH 1/2"THICK 2-M-W SHEATHING m O <br /> OR EQUAL W/8D COMMON NAILS @ 6"O.C.@ EDGES @ 12"O.C.IN FIELD,UNO. <br /> SHEATHING SHALL BE CONTINUOUS ACROSS ALL HORIZONTAL FRAMING JOINTS. KITCHEN W <br /> 14.ALL ROOF SHEATHING AND SUB-FLOORING SHALL BE INSTALLED WITH FACE <br /> GRAIN PERPENDICULAR TO SUPPORTS,EXCEPT AS INDICATED ON THE I 18'-8"X 6'-6" I be <br /> DRAWINGS.ROOF SHEATHING SHALL EITHER BE BLOCKED,TONGUE-AND- I 100 SQ FT <br /> GROOVE,OR HAVE EDGES SUPPORTED BY PLYCLIPS.SHEAR WALL SHEATHING o <br /> SHALL BE BLOCKED WITH 2X FRAMING AT ALL PANEL EDGES.SHEATH ROOFI O'O I M <br /> PRIOR TO ANY OVER FRAMING. <br /> 15. PLYWOOD PANELS SHALL CONFORM TO THE REQUIREMENTS OF'U.S.PRODUCT I lu- <br /> STANDARD PS 1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD"OR APA <br /> PRP-108 PERFORMANCE STANDARDS.UNO,PANELS SHALL BE APA RATED <br /> SHEATHING,EXPOSURE 1,OF THE THICKNESS AND SPAN RATING SHOWN ON THE II N <br /> DRAWINGS.PLYWOOD INSTALLATION SHALL BE IN CONFORMANCE WITH APA o <br /> RECOMMENDATIONS.ALLOW 1/8"SPACING AT PANELS ENDS AND EDGES, L— — — — — — — — — — — — — - -2L- ib*2i.--6--- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J <br /> UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. <br /> 16.GLULAM BEAMS SHALL BE FABRICATED IN CONFORMANCE WITH U.S.PRODUCT 6 SQ FT E <br /> STANDARD PS 56,'STRUCTURAL GLUED LAMINATED TIMBER"AND AMERICAN o <br /> INSTITUTE OF TIMBER CONSTRUCTION,ATTIC 117.EACH MEMBER SHALL BEAR <br /> AN ATIC OR APA-EWS IDENTIFICATION MARK AND BE ACCOMPANIED BY A s Eg <br /> � o <br /> CERTIFICATE OF CONFORMANCE.ONE COAT OF END SEALER SHALL BE APPLIED o <br /> IMMEDIATELY AFTER TRIMMING IN EITHER SHOP OR FIELD. o°O ` <br /> 17.GLULAM BEAMS SHALL BE 24F-V4 DF/DF OR EQUAL FOR SIMPLE SPANS,AND M o <br /> 24F-V8 DF/DF FOR CONTINUOUS SPANS. <br /> 18."VERSA-LAM"&"MICRO-LAM MEMBERS SHALL BE GRADE 2.0 E. <br /> 19.ANY WOOD IN CONTACT W/CONCRETE OR MASONRY SHALL BE PRESSURE <br /> TREATED. <br /> 20.ALL WOOD&IRON CONNECTORS SHALL BE INSTALLED W/ALL REQUIRED <br /> FASTENERS IN COMPLIANCE W <br /> 21.ALL HANGERS TO BE"SIMPSON/"TORTE UAL.TENAPPROVAL. LIVING AREA <br /> 22. NOTIFY EOR PRIOR TO DRILLING HOLES IN STEEL BEAMS. 480 SQ FT m <br /> IZ <br /> E1 Q (n <br /> Nw <br /> 0 <br /> 1ST FLOOR PLAN <br /> 1/2"=1' <br />