Laserfiche WebLink
PV MODULE RATING @ STC NOTE: (SOLAR PV SYSTEM EQUIPPED WITH Rooftop conductor ampacities designed in compliance with 120% RULE <br /> NEEDS TO BE LOCATED art.690.8,Tables 310.15(B)(1),310.15(C)(1),310.15(B)(2), • <br /> MANUFACTURER ZNSHINESOLAR ZXM7-SH108 410M RAPID SHUTDOWN) 310.16,Chapter 9 Table 4,5,&9.Location specific BUS BAR RATING X 120%) - MAIN BREAKER RATING <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS WITHIN 3FT OF AC DISCONNECT. temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD infinity o l0 r <br /> MAX.POWER-POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MODULE: 08 ZNSHINESOLAR ZXM7-SH108-410M RECORD LOW TEMP -8°c (200A x 120%) - 200 = 40A 6405 E OUVER A98 <br /> LAIN <br /> OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS ( ) VANCOUVER WA 98661 <br /> INVERTER: (04)AP SYSTEMS AMBIENT TEMP(HIGH TEMP 2%) 32°C PHONE:1-800-818-0598 <br /> SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS INFINITY <br /> NOM.MAX.POWER AT STC(PMAX) 410 WATT CONDUIT HEIGHT 7/8„ THIS PANEL IS FED BY MULTIPLE SOURCES <br /> ROOF TOP TEMP 54°C <br /> (UTILITY AND SOLAR) REVISIONS <br /> MAX.SYSTEM VOLTAGE 1500V NOTE : Description Date Rev <br /> 90°C <br /> VOC TEMPERATURE COEFFICIENT _0.29%/'C ATTIC RUN -YES CONDUCTOR TEMPERATURE RATE AC OUTPUT CURRENT 13A Initial Design 3/26124 00 <br /> SHUTDOWN - NO VISIBLE, LOCKABLE, LABELED DISCONNECT NOMINAL AC VOLTAGE 240V <br /> MICROINVERTERS SPECIFICATION WITHIN 10' OF UTILITY METER POINT OF INTERCONNECT,SUPPLY SIDE <br /> MICROINVERTER MAKE AP SYSTEMS EXISTING 240V/200A BUS BAR RATING, <br /> MICROINVERTER MODEL NO. DS3-L MAIN SERVICE PANEL,SINGLE PHASE, Signature with Seal <br /> MAXIMUM AC OUTPUT 768 W WITH A 200A MAIN BREAKER <br /> MAX INPUT VOLTAGE 60 V UTILITY COMPANY-P.U.D#1 <br /> MAX AC CURRENT 3.20 A SNOHOMISH COUNTY <br /> MAX OUTPUT VOLTAGE 240 V UTILITY METER#237733 <br /> EXISTING <br /> BI-DIRECTIONAL <br /> nn UTILITY METER, <br /> (N)BLADE TYPE 'V' 1-PHASE,3W, Project Name& <br /> (N)125A COMBINER PANEL, FUSIBLE AC DISCONNECT 120V/240V Address <br /> 240V,3W,1-PHASE NEMA 3R 60A-2P 120/240VAC LINE SIDE TAP <br /> (VISIBLE,LOCKABLE,LABELED) USING IPC <br /> LU <br /> 20A FUSES U <br /> 200A E--{ w <br /> 0 <br /> (E)LOADS (n <br /> I— <br /> Lu Cn <br /> ~ 00 <br /> M Q Q <br /> (08) ZNSHINESOLAR ZXM7-SH108-410M zp z a Z z <br /> 04 AP SYSTEMS INVERTERS (N)JUNCTION BOX (E)LOADS U) U �' w <br /> ( ) 600 V,NEMA 4 L1 LU W H z <br /> BRANCH 1-08 MODULES WITH 04 MICRO INVERTERS UL LISTED 20A 010° ° ' ° U I1--- O <br /> L2 LU O Of W <br /> W <br /> L1 L1 N Q N W <br /> G <br /> N U <br /> — --————I— i <br /> L2 L2 _ Off--- -- G u r G G Q <br /> L — J L — J L — J L — J - _ <br /> I <br /> 2 3 + 4 EXISTING GROUNDING Sheet Name <br /> ELECTRODE SYSTEM 3-LINE <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE DIAGRAM <br /> TAG# DEVICES RATING MULT CURR X 125% WIRE SIZE\TYPEWMP. OCP #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) <br /> Sheet Size <br /> #10\THWN\40A @90°C 20A 2 TRUNK CABLE 0.96 x 1.00 x 40A 38.40A ANSI B <br /> O 04 x 3.20 x N/A = 12.80A 16.00A IN AIR 12.80A #6 AWG 20 0.22 <br /> 11" X 17" <br /> Sheet Number <br /> O04 x 3.20 x N/A = 12.80A 16.00A #10\THWN\40A @90°C 20A 2 3/4" EMT 0.96 x 1.00 x 40A 38.40A 12.80A #8 AWG 50 0.55 E 1 .1 <br /> 0.86< <br /> 2 <br /> O04 x 3.20 x N/A = 12.80A 16.00A #6 \THWN\ 65A @75°C 20A 2 3/4" EMT 0.94 x 1.00 x 65A 61.10A 12.80A #8 AWG 10 0.047 <br /> L <br /> 04 x 3.20 x N/A = 12.80A 16.00A #6 \THWN\ 65A @75°C 20A 3 3/4" EMT 0.94 x 1.00 x 65A 61.10A 12.80A #8 AWG 10 0.047 <br />