Laserfiche WebLink
Product Bosch IDSBOVA 2.0 17 <br /> 4 Extended Performance Data <br /> 4.1 Outdoor Unit(BOVA)+Indoor Unit(BVA)-Cooling Mode <br /> _ BOVA 36 BVA 24 For Cooling <br /> TC 18.2 18.4 18.8 19.0 18.8 19.0 19.2 19.4 20.0 20.2 20.4 20.6 \ 26.2 26.4 26.7 <br /> 65 SIT 1.00 1.00 1.00 1.00 0.65 1.00 1.00 1.00 0.40 0.57 0.75 0.92 \ 0.39 0.52 0.66 <br /> kW 0.77 0.77 0.78 0.78 0.78 0.79 0.80 0.81 0.80 0.81 0.82 0.83 \ 1.05 1.06 1.08 <br /> TC 18.4 18.6 19.0 19.2 19.0 19.2 19.4 19.6 20.2 20.4 20.6 20.8 \ 25.8 26.1 26.3 <br /> 75 SIT 1.00 1.00 1.00 1.00 0.64 1.00 1.00 1.00 0.40 0.57 0.75 0.92 \ 0.39 0.53 0.66 <br /> kW 0.93 0.94 0.95 0.95 0.95 0.96 0.97 0.98 0.98 0.99 1.00 1.01 \ 1.31 1.33 1.35 <br /> TC 18.4 18.6 19.0 19.2 19.0 19.2 19.4 19.6 20.2 20.4 20.6 20.8 \ 25.8 26.0 26.3 <br /> 85 SIT 1.00 1.00 1.00 1.00 0.64 1.00 1.00 1.00 0.40 0.57 0.75 0.92 \ 0.39 0.53 0.66 <br /> 660 kW 1.10 1.11 1.13 1.13 1.13 1.14 1.15 1.16 1.16 1.17 1.18 1.19 \ 1.45 1.46 1.48 <br /> TC 18.3 18.5 18.9 19.1 18.9 19.1 19.3 19.5 20.1 20.4 20.5 20.8 \ 25.7 25.9 26.1 <br /> 95 SIT 1.00 1.00 1.00 1.00 0.64 1.00 1.00 1.00 0.40 0.57 0.75 0.92 \ 0.39 0.53 0.66 <br /> kW 1.33 1.35 1.36 1.36 1.36 1.38 1.39 1.40 1.41 1.42 1.43 1.45 \ 1.76 1.77 1.79 <br /> TC 18.2 18.4 18.8 19.0 18.8 19.0 19.2 19.4 20.1 20.3 20.5 20.7 \ 25.4 25.7 25.9 <br /> 105 SIT 0.99 1.00 1.00 1.00 0.64 0.99 1.00 1.00 0.40 0.57 0.75 0.92 \ 0.39 0.53 0.67 <br /> kW 1.60 1.61 1.63 1.63 1.63 1.65 1.67 1.68 1.69 1.70 1.72 1.73 \ 2.11 2.13 2.15 <br /> TC 17.9 18.1 18.5 18.7 18.5 18.7 18.9 19.1 19.8 20.0 20.1 20.3 \ 25.2 25.4 25.7 <br /> 115 SIT 1.00 1.00 1.00 1.00 0.64 0.99 1.00 1.00 0.40 0.58 0.76 0.93 \ 0.39 0.53 0.67 <br /> kW 1.87 1.89 1.91 1.91 1.91 1.94 1.96 1.98 1.98 2.00 2.02 2.04 \ 2.52 2.54 2.56 <br /> TC 20.1 20.3 20.8 21.0 20.8 21.0 21.2 21.5 22.2 22.4 22.6 22.9 \ 28.6 28.9 29.1 <br /> 65 SIT 1.00 1.00 1.00 1.00 0.66 1.00 1.00 1.00 0.39 0.58 0.76 0.94 \ 0.39 0.53 0.67 <br /> kW 0.91 0.92 0.93 0.93 0.93 0.94 0.95 0.96 0.95 0.96 0.97 0.99 \ 1.22 1.23 1.24 <br /> TC 20.3 20.5 21.0 21.2 21.0 21.2 21.4 21.7 22.4 22.6 22.8 23.0 \ 28.7 29.0 29.2 <br /> 75 SIT 1.00 1.00 1.00 1.00 0.65 1.00 1.00 1.00 0.39 0.58 0.76 0.94 \ 0.39 0.53 0.67 <br /> kW 1.08 1.09 1.10 1.10 1.10 1.12 1.13 1.14 1.14 1.15 1.16 1.18 \ 1.45 1.47 1.49 <br /> TC 20.3 20.5 21.0 21.2 21.0 21.2 21.4 21.7 22.3 22.6 22.8 23.0 \ 28.4 28.6 28.9 <br /> 85 SIT 0.99 1.00 1.00 1.00 0.65 1.00 1.00 1.00 0.39 0.58 0.76 0.94 \ 0.39 0.53 0.68 <br /> kW 1.24 1.25 1.26 1.26 1.26 1.28 1.29 1.30 1.31 1.32 1.33 1.34 \ 1.63 1.64 1.66 <br /> 760 TC 20.2 20.4 20.9 21.1 20.9 21.1 21.3 21.6 22.2 22.5 22.7 22.8 \ 28.1 28.4 28.6 <br /> 95 SIT 0.99 1.00 1.00 1.00 0.65 1.00 1.00 1.00 0.39 0.58 0.75 0.95 \ 0.39 0.53 0.68 <br /> kW 1.49 1.51 1.52 1.52 1.52 1.54 1.55 1.57 1.58 1.59 1.60 1.61 \ 1.96 1.99 2.00 <br /> TC 19.8 20.1 20.5 20.7 20.5 20.7 20.9 21.2 21.9 22.1 22.3 22.5 \ 27.8 28.1 28.3 <br /> 105 SIT 0.99 1.00 1.00 1.00 0.65 1.00 1.00 1.00 0.39 0.58 0.77 0.95 \ 0.39 0.53 0.68 <br /> kW 1.76 1.78 1.80 1.80 1.80 1.82 1.83 1.85 1.86 1.88 1.89 1.91 \ 2.35 2.37 2.40 <br /> TC 19.7 19.9 20.4 20.6 20.4 20.6 20.8 21.0 21.7 21.9 22.1 22.4 \ 27.5 27.7 28.0 <br /> 115 SIT 1.00 1.00 1.00 1.00 0.65 1.00 1.00 1.00 0.39 0.58 0.77 1 0.96 \ 0.39 0.54 0.69 <br /> kW 2.09 2.11 2.13 2.13 2.13 2.16 2.18 2.20 2.21 2.23 2.25 2.27 \ 2.82 2.85 2.88 <br /> TC 22.3 22.5 23.0 23.3 23.0 23.3 23.5 23.8 24.6 24.8 25.0 25.3 \ 31.1 31.4 31.7 <br /> 65 SIT 1.00 1.00 1.00 1.00 0.66 1.00 1.00 1.00 0.39 0.58 0.77 0.95 \ 0.39 0.54 0.68 <br /> kW 0.99 1.00 1.01 1.01 1.01 1.02 1.04 1.05 1.04 1.06 1.07 1.08 \ 1.41 1.43 1.45 <br /> TC 22.0 22.3 22.8 23.0 22.8 23.0 23.3 23.5 24.4 24.7 24.8 24.8 \ 31.2 31.4 31.7 <br /> 75 SIT 1.00 1.00 1.00 1.00 0.66 1.00 1.00 1.00 0.39 0.58 0.77 1.00 \ 0.39 0.54 0.68 <br /> kW 1.23 1.25 1.26 1.26 1.26 1.27 1.29 1.30 1.31 1.32 1.33 1.33 \ 1.66 1.68 1.70 <br /> TC 21.9 22.1 22.6 22.9 22.6 22.9 23.1 23.4 24.4 24.5 24.6 24.8 \ 30.8 31.1 31.3 <br /> 85 SIT 1.00 1.00 1.00 1.00 0.66 1.00 1.00 1.00 0.39 0.59 0.78 1.00 \ 0.39 0.54 0.69 <br /> 860 kW 1.36 1.38 1.39 1.39 1.39 1.41 1.42 1.44 1.46 1.46 1.46 1.48 \ 1.81 1.83 1.85 <br /> TC 21.7 22.0 22.5 22.7 22.5 22.7 22.9 23.2 24.0 24.2 24.4 24.6 \ 30.5 30.7 30.9 <br /> 95 SIT 1.00 1.00 0.99 1.00 0.66 1.00 1.00 1.00 0.39 0.59 0.78 1.00 \ 0.39 0.54 0.69 <br /> kW 1.62 1.64 1.66 1.66 1.66 1.68 1.69 1.71 1.73 1.74 1.75 1.77 \ 2.19 2.21 2.22 <br /> TC 21.5 21.8 22.3 22.5 22.3 22.5 22.8 23.0 23.8 24.0 24.2 24.5 \ 30.0 30.2 30.5 <br /> 105 SIT 0.99 1.00 1.00 1.00 0.66 1.00 1.00 1.00 0.39 0.59 0.78 1.00 \ 0.39 0.54 0.70 <br /> kW 1.95 1.97 1.99 1.99 1.99 2.01 2.03 2.05 2.06 2.08 2.09 2.11 \ 2.63 2.65 2.68 <br /> TC 21.4 21.6 22.1 22.3 22.1 22.3 22.6 22.8 23.6 23.8 24.0 24.2 \ 28.8 28.8 28.7 <br /> 115 SIT 0.99 1.00 1.00 1.00 0.66 1.00 1.00 1.00 0.39 0.59 0.79 0.99 \ 0.39 0.55 0.72 <br /> kW 2.31 2.33 2.36 2.36 2.36 2.38 2.41 2.43 2.44 2.46 2.48 2.50 \ 3.00 3.00 3.00 <br /> Table 2 <br /> TC refer to total capacity S/T:refer to the ratio of sensible heat and total capacity kW:refer to total input power <br /> Bosch Thermotechnology Corp.104.2019 Data subject to change <br />