ROOF MOUNT PHOTOVOLTAIC SYSTEM <br /> CODES: CONSTRUCTION NOTES: <br /> THIS PROJECT COMPLIES WITH THE FOLLOWING: <br /> 2018 INTERNATIONAL BUILDING CODE CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND <br /> 2018 INTERNATIONAL RESIDENTIAL CODE ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. <br /> 2018 INTERNATIONAL FIRE CODE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT <br /> 2018 INTERNATIONAL ENERGY CONSERVATION CODE POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE <br /> 2018 INTERNATIONAL EXISTING BUILDING CODE MOUNTED. <br /> 2018 INTERNATIONAL FUEL GAS CODE MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN <br /> 2018 INTERNATIONAL MECHANICAL CODE ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER <br /> 2018 INTERNATIONAL PLUMBING CODE SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. <br /> 2020 NATIONAL ELECTRICAL CODE <br /> AS ADOPTED BY CITY OF EVERETT DIG ALERT (811)TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY <br /> EXCAVATION TAKING PLACE <br /> PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM <br /> DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). <br /> SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH <br /> VICINITY MAP: REQUIREMENTS OF ART. 690 OF THE 2020 NEC <br /> THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR LIFER <br /> UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM <br /> CLIENT: <br /> JAMES IMHOF <br /> INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 6323 W BEECH ST,EVERETT,WA 98203 <br /> AHJATTACHED TO THE ROOF USING CONDUIT MOUNT. UTILITY: <br /> CITY of EVERETT <br /> P <br /> - - UTILITY:SNOHOMISH PUD <br /> METER:52235833 <br /> APN:006120-000-079-00 <br /> Q PHONE:(425)348-7344 <br /> O EMAIL:JIMIMHOF@GMAIL.COM <br /> (}�{} THIS SYSTEM DESIGNED WITH: <br /> Taylormade Care 9 Q WIND SPEED: 85 <br /> SYSTEM: <br /> WIND EXPOSURE: B SYSTEM SIZE(DC):15 X 395=5.925 kW <br /> SNOW LOAD: 20 SYSTEM SIZE(AC):4.350 kW @ 240V <br /> MODULES:15 X CANADIAN SOLAR: <br /> CS6R-395MS-HL <br /> MICROINVERTERS:15 X ENPHASE <br /> IQ8PLUS-72-2-US <br /> SITE LOCATION <br /> TABLE OF CONTENTS: <br /> PV-1 PROJECT DETAILS <br /> REVISIONS <br /> PV-2 SITE PLAN NO. REVISED BY DATE <br /> PV-2A ROOF PLAN WITH MODULES LAYOUT <br /> PV-213 ARRAY DETAILS <br /> PV-3 MOUNTING DETAILS <br /> �-�rfreedom­ <br /> PV-4 THREE LINE DIAGRAM A F v E <br /> PV-5 CONDUCTOR CALCULATIONS FREEDOM FOREVER LLC <br /> 43445 BUSINESS PARK DR#110,TEMECULA, <br /> PV-6 EQUIPMENT&SERVICE LIST CA 92590 <br /> Tel:(800)385-1075 <br /> PV-7 LABELS GREG ALBRIGHT <br /> PV-7A SITE PLACARD <br /> �� ^A— <br /> PV_8 MICROINVERTER CHART <br /> PV-9 SAFETY PLAN CONTRACTOR LICENSE: <br /> ELECTRICAL ADMINISTRATOR ALBRIG`807C1 <br /> PV-10 SAFETY PLAN <br /> APPENDIX MANUFACTURER SPECIFICATION SHEETS <br /> PROJECT DETAILS <br /> JOB NO: DATE: DESIGNED BY: SHEET: <br /> 430927 4/25/2024 A.I. PV-1 <br />