Laserfiche WebLink
Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-Apr-2016 Re ort No. 102393982LAX-002 Page 4 of 138 Issued: 11-Apr-2016 <br /> Unirac,Inc Revised: 5-Oct-2022 Unirac,Inc Revised: 5-Oct-2022 BLUE RAVEN <br /> 2.0 Product Description 2.0 Product Description SOLAR <br /> Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Models Unirac SFM <br /> Brand name Unirac Model Similarity NA <br /> The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic <br /> Rack Mounting System. This system is designed to provide bonding and grounding to Fuse Rating: 30A <br /> photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets <br /> that are roof mounted using the slider,outlined in section 4 of this report. There are no rails Module Orientation:Portrait or Landscape <br /> within this product,whereas the 3"Micro Rail,Floating Splice,and 9"Attached Splice Maximum Module Size: 17.98 ft2 <br /> electrically bond the modules together forming the path to ground. UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope <br /> Tested Loads -50 psf/2400Pa Downward, 50psF2400Pa Uplift, 15psF720Pa Down Slope <br /> The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading <br /> with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the <br /> modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued,penetrate Increased size ML test: <br /> the anodized coating of the photovoltaic module frame (at bottom flange)to contact the metal, Maximum Module Size:22.3 ft2 <br /> creating a bonded connection from module to module. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope <br /> Description LG355S2W-A5 <br /> The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. <br /> National Electrical Code, including NEC 250: Grounding and Bonding,and NEC 690: Solar Mounting configuration: Four mountings on each long side of panel with the longest span of 24" <br /> Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating: 46.9 PSF Downward,40 PSF Upward, 10 PSF Down-Slope <br /> revision in effect in the jurisdiction in which the project resides. Any local electrical codes must LG395N2W-A5, <br /> be adhered in addition to the national electrical codes. The Grounding Lug is secured to the LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. <br /> photovoltaic module, torqued in accordance with the installation manual provided in this Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" <br /> document. IEC 61646 Test Loads - 112.78 psF5400Pa Downward, 50psF2400Pa Uplift <br /> Other optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 <br /> which requires a minimum oft micro-inverters mounted to the same rail, and using the same Certifications, &Increase SFM System UL2703 Module Size: <br /> engage cable. Maximum Module Size: 27.76 ft2 <br /> UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope <br /> Jinko Eagle 72HMG5 used for Mechanical Loading test. <br /> Mounting configuration: Four mountings on each long side ofpanelwith the longest span of 24" <br /> Mamzimum module size: 21.86 ft2 <br /> IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift <br /> SunPower model SPR-A430-COM-MLSD used for Mechanical Loading <br /> Fire Class Resistance Rating: <br /> -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any <br /> interstitial gap. Installations must include Trim Rail <br /> -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any <br /> interstitial gap. Installations must include Trim Rail <br /> -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. <br /> This system was evaluated with a 5"gap between the bottom of the module and the roof's <br /> surface <br /> See section 7.0 illustractions # 1, la and lb for a complete list of PV modules evaluated with <br /> these racking systems <br /> Other Ratings NA <br /> DRAWING NUMBER: <br /> ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory C C <br />