Laserfiche WebLink
Design Ratio <br /> Member ID Mi Vy SR D Status <br /> 1 0.007 0.488 0.194 0.487 0.035 0.25 Pass <br /> 2 0.008 0.101 0.124 0.11 0.035 0.21 Pass <br /> Member Design Capacity(LRFD) <br /> Member ID F b(ksi) F t(ksi) F v(ksi) F.(ksi) F�P(ksi) E(ksi) Emin(ksi) <br /> 1 2.681 1.49 0.311 2.683 0.939 1600.0 1041.216 <br /> 2 2.681 1.49 0.311 2.683 0.939 1600.0 1041.216 <br /> Node Coordinates <br /> X Coordinate Y Coordinate <br /> 1 0.000 0.000 <br /> 2 8.000 3.902 <br /> 3 16.000 7.804 <br /> 4 -1.500 -0.732 <br /> Members <br /> ID Node A Node B Section Node A Fixity Node B Fixity Length <br /> 1 1 3 1 FFFFFF FFFFFF 17.802 <br /> 2 4 1 1 FFFFFF FFFFFF 1.669 <br /> Supports <br /> Node ID <br /> 1 2 RFFRRR <br /> 2 3 RFFRRR <br /> 3 1 FFFFFR <br /> Materials <br /> ID Name Young's Modulus Density Poisson's Ratio <br /> 1 NDS-Table 4A-DOUGLAS FIR-LARCH-No.2-2in&wider 1600.000 33.308 0.400 <br /> Sections <br /> ID Name Depth Width Shear Area Z Shear Area Y Torsion Radius <br /> 1 1.5 x 3.5 4.000 1.500 5.000 5.000 1.463 <br /> ID Centroid Y Centroid Z Y-Axis Mol Z-Axis Mol Torsion Constant <br /> 1 0.750 2.000 6.000 1.125 8.000 3.437 <br /> Point Loads <br /> ID Load Group Member Position% Y Magnitude <br /> 1 Solar-Snow 2 66.667% -0.087 <br /> 2 Solar 2 66.667% -0.012 <br /> 3 Solar-Snow 1 16.300% -0.087 <br /> 4 Solar 1 16.300% -0.012 <br /> 5 Solar-Snow 1 35.725% -0.087 <br /> 6 Solar 1 35.725% -0.012 <br /> Member Distributed Loads <br /> ID Load Group Start Positio End Position Member Y Magnitude <br /> 1 Dead Load 0.000% 100.000% 2 -0.009 <br /> 2 Dead Load 0.000% 100.000% 1 -0.009 <br /> 3 Roof Live Load 48.901% 100.000% 1 -0.021 <br /> 4 Snow Load 48.901% 100.000% 1 -0.023 <br /> Load Combinations <br /> Roof Live Load <br /> ID Name Dead Load Factor Snow Load Factor7 Solar Factor Solar-Snow Factor <br /> Factor <br /> 581 E Technology Ave, C1500 Orem, UT 84097 925-787-3067 www.rightangleeng.com Page of <br />