MICROINVERTERS SPECIFICATION PV MODULE RATING A STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8, Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 0 <br /> MICROINVERTER MODEL NO. DS3-L 310.16, Chapter 9 Table 4, 5, &9. Locations specific BUS BAR RATING X 120%) - MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p infinity <br /> solar <br /> AC OUTPUT 768 W temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER POINT VOLTAGE(Vi 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA 98661 <br /> PHONE:1-800-818-0598 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP 5°CINFINITY SOLAR.COM <br /> AMBIENT TEMP HIGH TEMP 2°/ ° THIS PANEL IS FED BY MULTIPLE SOURCES <br /> MODULE: (12) ZNSHINESOLAR ZXM7-SH108-410M NOM.MAX.POWER AT STC(PMAX) 410 WATT ( �) 26 C UTILITY AND SOLAR)) REVISIONS <br /> INVERTER: (06)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V CONDUIT HEIGHT 7/8" Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C AC OUTPUT CURRENT 19A Initial Design 4/18/24 00 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT CONDUCTOR TEMPERATURE RATE 901C NOMINAL AC VOLTAGE 240V <br /> WITHIN 10' OF UTILITY METER NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED NOTE:-TANDEM BREAKERS TO BE USED TO <br /> NOTE : WITHIN 3FT OF AC DISCONNECT. MAKE ROOM FOR PV CIRCUIT BREAKER POINT OF INTERCONNECT, LOAD SIDE Signature with Seal <br /> ATTIC RUN -YES EXISTING 240V/200A BUS BAR RATING, <br /> SHUTDOWN - NO MAIN SERVICE PANEL,SINGLE PHASE, <br /> WITH A 200A MAIN BREAKER <br /> UTILITY COMPANY-SNOHOMISH COUNTY <br /> UTILITY METER#76 376 932 <br /> EXISTING <br /> NALTI <br /> DIRECO <br /> (12)ZNSHINESOLAR ZXM7-SH108-410M BI- Project Name& <br /> (06)AP SYSTEMS DS3-L INVERTERS (N) 125A COMBINER PANEL, (N) BLADE TYPE M UTILITY METER, Address <br /> 240V,3W,1-PHASE NON-FUSIBLE AC DISCONNECT 1-PHASE,3W, <br /> BRANCH 1 -06 MODULES WITH 03 MICRO INVERTERS NEMA 3R 30A-2P 120/240VAC 120V/240V <br /> (VISIBLE, LOCKABLE, LABELED) <br /> 200A E--{ z <br /> (E)LOADS p LL o <br /> i� N > MQQ <br /> a $ a $ $ (N)JUNCTION BOX �'� Q z z <br /> 600 V, NEMA 4 15A (N)PV BREAKER w }O Lu J <br /> UL LISTED 30A/2P QFir = w o <br /> ---------- ---------- --------i 15A L1 �\ U CII w <br /> BRANCH 2-06 MODULES WITH 03 MICRO INVERTERS L1 L1 L2 w <br /> L2 L2 UJ <br /> I <br /> L1 L1 G <br /> FL2 r F------ ------ ----- ----- ------- <br /> I G I I <br /> ---- — G I G <br /> Ell]EIE]I][ I <br /> LJ L J L J J L <br /> 1 Sheet Name <br /> � � � <br /> __________ __________ -------- EXISTING-GROUNDING 3-LINE <br /> 1 2 3 3 ELECTRODE SYSTEM DIAGRAM <br /> Sheet Size <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPE\AMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE 11" X 17„ <br /> TAG# DEVICES RATING MULT CURR X125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(/o) <br /> Sheet Number <br /> 03 x 3.20 x N/A = 9.60A 12.00A #10\THWN \40A @90°C 15A 2 TRUNK IN AIR BLE 1.00 x 1.00 x 40A 40.00A <br /> 9.60A #6 AWG 20 0.28 E 1 .1 <br /> O 03 x 3.20 x N/A = 9.60A 12.00A #10\THWN \40A @90°C 15A 4 3/4" EMT 1.00 x 0.80 x 40A 32.00A 9.60A #8 AWG 35 0.48 0.93< <br /> 2 <br /> O06 x 3.20 x N/A = 19.20A 24.00A #10\THWN \ 35A @75°C 30A 2 3/4" EMT 1.00 x 1.00 x 35A 35.00A 19.20A #8 AWG 10 0.17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.