Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS SYSTEM LEGEND <br /> SYSTEM SIZE: 2.870 kW DC NUMBER OF MODULES 07 ZNSHINESOLAR ZXM7-SH108-410MEXISTING INTERIOR MAIN SERVICE PANEL&POINT 0 <br /> 3.072 kW AC NUMBER OF INVERTER 04 AP SYSTEMS DS3-L M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY infinit olar <br /> MODULE TYPE&AMOUNT: (07)ZNSHINESOLAR ZXM7-SH108-410M METER#86 877139. y <br /> MODULE DIMENSIONS: (LM/H)67.87"/44.64"/1.8" COMBINER PANEL 2 EATON BR STYLE 1 INCH LOAD CENTER <br /> INVERTER: (04)AP SYSTEMS DS3-L 816L125RP AC NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY <br /> E MILL PLAIN HOME SOLUTIONS <br /> AHJ: CITY OF EVERETT AC DISCONNECT 1 30A NON-FUSIBLE AC DISCONNECT,240V LOCATED WITHIN 10'FROM THE UTILITY METER 6 VANCOUVER PL9 <br /> 8661 <br /> CHIKO AL ROOF HOOK#167 PHONE:1-800-818-0598 <br /> NUMBER OF ATTACHMENTS 22 CK-FTS-167RT2 © NEW DEDICATED PV SYSTEM COMBINER PANEL. INFINITY SOLAR.COM <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT 2810 22ND ST <br /> RAILS 5 GRASOL RACKING SYSTEM REVISIONS <br /> WITHIN 10'OF UTILITY METER <br /> FRONT OF HOUSE RAIL SPLICE 0 SPLICE KIT 07 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES <br /> Description Date Rev <br /> NOTE : MID CLAMPS 8 MID CLAMPS/UFO WITH NEW(04)-AP SYSTEMS DS3-L INVERTERS. Initial Design 4/1/24 00 <br /> ATTIC RUN -YES END CLAMPS 12 END CLAMPS/STOPPER SLEEVE <br /> ATTIC FAN -NO GROUNDING LUG 6 GROUNDING LUG =FIRE PATHWAY <br /> SHUTDOWN- NO <br /> MODULE, ARRAY WEIGHT (LOAD ❑O =ROOF OBSTRUCTIONS Signature with Seal <br /> CALC'S) <br /> • <br /> — Number of Modules 07 =ATTACHMENT POINTS <br /> - Module Weight 45.19 LBS =RAFTER <br /> M —_ <br /> Total Module rray)Weight 316.33 LBS <br /> Number of Attachment point 22 -—- =RACKING SYSTEM <br /> m Mounting System Weight 1.5 LBS <br /> W fPerModule) —— =ATTIC RUN <br /> LU Mounting System Weight 33.00 LBS Project Name& <br /> Address <br /> ROOF#02 Total System Weight =CONDUIT ATTIC RUN JUNCTION BOX <br /> M fModule Weight I mounting System Weight) 349.33 LBS <br /> Weight at Each Attachment Point <br /> 14.38 LBS <br /> II Arra Wei ht/NumberotAttachment Point I I <br /> Y 9 ) <br /> Module Area(67.87"x44.64") 21.04 SgFt <br /> W <br /> ❑ Total Array Area 147.28 SgFt Z <br /> j Distributed Load Ft 2 22 Per Q <br /> I (Total System Weight/Total Array Area) S <br /> q ROOF SECTIONS Z;5 C/) M Q Q <br /> Total Roof Area 1287 SgFt LU o < z z <br /> Total Percentage or Roof Covered 11.44% ROOF#01 MODULE-05 w cN�, z J <br /> C Total Any Area/Total Roo(Area)'1°° SLOPE-30° J o � O Q <br /> AZIMUTH-181° 2 00 � = W <br /> NEW AC COMBINER PANEL / MATERIAL-COMPOSITE SHINGLE 2 N w a- <br /> O RAFTER SIZE&SPACING-2"X4"@ 24"O.C. I j <br /> NEW PV AC DISCONNECT GROUPED o RooF#o2 MODULE-02 Q <br /> WITH SERVICE EQUIPMENT(VISIBLE, SLOPE-30° <br /> LOCKABLE,LABELED) AZIMUTH-181° <br /> I MATERIAL-COMPOSITE SHINGLE <br /> EXISTING INTERIOR MAIN SERVICE PANEL I RAFTER SIZE&SPACING-2"X4"@ 24"O.C. <br /> &POINT OF INTERCONNECTION.TIED TO <br /> EXTERIOR UTILITY METER#86 877139 Sheet Name <br /> Y <br /> m <br /> LU <br /> SITE PLAN <br /> LU <br /> LL Sheet Size <br /> 8' l s BaF M ANSI B <br /> 8' IRE SETBACK 11" X 17" <br /> Y N <br /> Q Sheet Number <br /> PV1 .1 <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATEDq� �z <br /> WITHIN 3FT OF AC DISCONNECT. -4 T-2" 11'4' 3'-7" <br /> NEW PV ATTACHMENTS AT 4'-0"O.C. <br /> CIRCUIT(S) <br /> 1 SITE PLAN CIRCUIT#1 -07 MODULES WITH 04 MICROINVERTERS <br /> Pv 1.1 SCALE:1/8"=1'-0" <br />